This is a
Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing.
Oomi Mote is an intelligent Z-Wave remote controller that mounted on a wall. It has 4 touch buttons that you can easily control the Z-Wave devices in your home network via touching, long pressing or sliding the button areas. Its surface has a RGB LED to indicate the button actions also accompanied by touch beep and vibration. The Mote is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade.
Reset to factory default | Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is missing or inoperable. |
Inclusion | Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing. |
Exclusion | Turn the primary controller of Z-Wave network into exclusion mode, short press the products Action button that you can find on the product's housing. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline.When touching the Button 1 to 4, the Central Scene Notificcation command will be sent to the associated node (1) in Association group 1. |
2 | 5 | When touching the Button 1, the Basic Set command will be sent to the associated nodes in Association group 2. |
3 | 5 | When touching the Button 1, the Multilevel Switch Set command will be sent to the associated nodes in Association group 3. |
4 | 5 | When touching the Button 2, the Basic Set command will be sent to the associated nodes in Association group 4. |
5 | 5 | When touching the Button 2, the Multilevel Switch Set command will be sent to the associated nodes in Association group 5. |
6 | 5 | When touching the Button 3, the Basic Set command will be sent to the associated nodes in Association group 6. |
7 | 5 | When touching the Button 3, the Multilevel Switch Set command will be sent to the associated nodes in Association group 7. |
8 | 5 | When touching the Button 4, the Basic Set command will be sent to the associated nodes in Association group 8. |
9 | 5 | When touching the Button 4, the Multilevel Switch Set command will be sent to the associated nodes in Association group 9. |
Enable/disable the touch sound. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Enable |
0 | Disable |
Enable/disable the touch vibration. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Enable |
0 | Disable |
Reset the Mote to factory default. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reset all configuration parameters to factory default setting |
1431655765 | Reset to factory default setting and removed from the z-wave network |
Enable/disable the function of button slide. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Set the low battery value.. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
5 - 50 | The value range is 5% to 50%. |
To set which notification would be sent to the associated devices (Group 1) when pressing the buttons. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Send Central Scene Command Notification |
3 | Send Central Scene Command Notification and Configuration report |
Hardware Platform | ZM5101 |
Device Type | Wall Controller |
Network Operation | Portable Slave |
Firmware Version | HW: 130 FW: 1.07 |
Z-Wave Version | 6.61.00 |
Certification ID | ZC10-17045534 |
Z-Wave Product Id | 0x016A.0x0202.0x0082 |
Firmware Updatable | Updatable by Consumer by RF |
Z-Wave Scene Type | Central Scene |
Supported Notification Types | Power Management |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |