Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing.
Oomi Dual In-Wall Switch is a Z-Wave Smart Switch specifically used to enable Z-Wave command and control (on/off) of any wall switches. It can report immediate wattage consumption or kWh energy usage over a period of time. In the event of power failure, non-volatile memory retains all programmed information relating to the units operating status.It can connect to 2 external manual switches to control the load ON/OFF independently. Its surface has a pin socket, which can be used for connecting to the touch panel, so you can also use the touch panel to control the Dual Nano Switch.The Dual In-Wall Switch is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade.
Reset to factory default | Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. |
Inclusion | Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing. |
Exclusion | Turn the primary controller of Z-Wave network into exclusion mode, short press the products Action button that you can find on the product's housing. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline.When the load state of Dual Nano Switch (turn on/off the load) is changed, the Hail CC and Basic Report (configured by parameter 80) can be sent to the associated nodes in this group. |
2 | 5 | Forward the Basic Set, Switch All, Scene Activation Set to associated nodes in Group 2 when the Dual Nano Switch receives the Basic Set, Switch All, Scene Activation Set commands from main controller. (E.g. Send/forward Basic Set to control the other nodes in association Group 2) |
3 | 5 | Send Basic Set (configured by parameter 0x51 ) to the associated nodes in Group 3 when the external switch S1 is operated.Note: The Switch Mode of external switch S1 should be identified successfully, which means that the value of Configuration parameter 0x78 should be non-zero, then the Basic Set can be sent to the associated nodes in Group 3 via triggering the S1 switch. |
4 | 5 | Send Basic Set (configured by parameter 0x52) to the associated nodes in Group 4 when the external switch S2 is operated.Note: The Switch Mode of external switch S2 should be identified successfully, which means that the value of Configuration parameter 0x79 should be non-zero, then the Basic Set can be sent to the associated nodes in Group 3 via triggering the S2 switch. |
Set parameter 101-103 to default value. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reset the parameter 101-103 |
To set which reports need to be sent in Report group 1. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
4 | Send Meter Report of voltage (V) |
2 | Send Meter Report of wattage (W) |
2048 | Send Multi Channel Meter Report of energy (kWh) on Channel 1 |
512 | Send Multi Channel Meter Report of wattage (W) on Channel 2 |
1048576 | Send Multi Channel Meter Report of current (A) on Channel 2 |
524288 | Send Multi Channel Meter Report of current (A) on Channel 1 |
8 | Send Meter Report of current (A) |
131072 | Send Multi Channel Meter Report of voltage (V) on Channel 2 |
1 | Send Meter Report of energy (kWh) |
256 | Send Multi Channel Meter Report of wattage (W) on Channel 1 |
4096 | Send Multi Channel Meter Report of energy (kWh) on Channel 2 |
65536 | Send Multi Channel Meter Report of voltage (V) on Channel 1 |
To set which reports need to be sent in Report group 2. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Send Meter Report of energy (kWh) |
2 | Send Meter Report of wattage (W) |
4 | Send Meter Report of voltage (V) |
8 | Send Meter Report of current (A) |
256 | Send Multi Channel Meter Report of wattage (W) on Channel 1 |
512 | Send Multi Channel Meter Report of wattage (W) on Channel 2 |
2048 | Send Multi Channel Meter Report of energy (kWh) on Channel 1 |
4096 | Send Multi Channel Meter Report of energy (kWh) on Channel 2 |
65536 | Send Multi Channel Meter Report of voltage (V) on Channel 1 |
131072 | Send Multi Channel Meter Report of voltage (V) on Channel 2 |
524288 | Send Multi Channel Meter Report of current (A) on Channel 1 |
1048576 | Send Multi Channel Meter Report of current (A) on Channel 2 |
To set which reports need to be sent in Report group 3. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Send Meter Report of voltage (V) |
2 | Send Meter Report of current (A) |
4 | Send Meter Report of wattage (W) |
8 | Send Meter Report of energy (kWh) |
256 | Send Multi Channel Meter Report of wattage (W) on Channel 1 |
512 | Send Multi Channel Meter Report of wattage (W) on Channel 2 |
2048 | Send Multi Channel Meter Report of energy (kWh) on Channel 1 |
4096 | Send Multi Channel Meter Report of energy (kWh) on Channel 2 |
65536 | Send Multi Channel Meter Report of voltage (V) on Channel 1 |
131072 | Send Multi Channel Meter Report of voltage (V) on Channel 2 |
524288 | Send Multi Channel Meter Report of current (A) on Channel 1 |
1048576 | Send Multi Channel Meter Report of current (A) on Channel 2 |
Set parameter 111-113 to default value. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reset the parameter 111-113 |
Set the interval of automatic report for Report group 1. Size: 4 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 2147483647 | The range of interval time is 1 to 2147483647. |
Set the interval of automatic report for Report group 2. Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
1 - 2147483647 | The range of interval time is 1 to 2147483647. |
Set the interval of automatic report for Report group 3. Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
1 - 2147483647 | The range of interval time is 1 to 2147483647. |
Configure the external switch mode for S1. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Enter automatic identification mode |
1 | 2-state switch mode |
2 | 3 way switch mode |
3 | Momentary push button mode |
Configure the external switch mode for S2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | 2-state switch mode |
2 | 3 way switch mode |
0 | Enter automatic identification mode |
3 | Momentary push button mode |
Set the control destination for external switch Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 | control the output loads of itself. |
2 | control the other nodes |
3 | control the output loads of itself and other nodes. |
Configure the output status after re-power on it. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
2 | Always off |
1 | Always on |
0 | Last status |
Lock/unlock configuration parameters. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unlock |
1 | Lock |
Reset the Dual In-Wall Switch to factory default. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reset all configuration parameters to factory default setting |
1431655765 | Reset to factory default setting and removed from the z-wave network |
Output Load will be turned off automatically after 30 seconds and if the current overrun 10.5A. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Output Load will be turned off automatically after 30 seconds and if the temperature of product inside exceeds 100 . Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
To set which notification would be sent to the associated devices (Group 1) when the state of Dual Nano Switchrs load is changed. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Send Nothing |
1 | Send Hail CC |
2 | Send Basic CC report |
3 | Send Hail CC when using the manual switch to change the load state. |
To set which notification would be sent to the associated nodes in association Group 3 when using the external switch 1 to switch the loads. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Send Nothing |
1 | Send Basic Set CC |
To set which notification would be sent to the associated nodes in association Group 4 when using the external switch 2 to switch the loads. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Send Nothing |
1 | Send Basic Set CC |
Configure the state of LED when it is in 3 modes (Energy mode, Momentary indicate mode, Night light mode) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
2 | Night light mode. The LED will remain ON state. |
0 | Energy mode. The LED will follow the status (on/off). |
1 | Momentary indicate mode. When the state of Switchs load changed, the LED will follow the status (on/off) of its load, but the LED will turn off after 5 seconds if there is no any switch action. |
Set the ON/OFF time of the LED when it is in Night light mode. Size: 4 Byte, Default Value: 301991936
Setting | Description |
---|---|
0 - 60 | The minute time of OFF |
256 - 316 | The hour time of OFF |
65536 - 65596 | The minute time of ON |
16777216 - 16777276 | The hour time of ON |
Set the ON time of output load. Size: 4 Byte, Default Value: 8327680
Setting | Description |
---|---|
256 - 316 | The hour value of ON time |
16777215 | Disable the setting. |
0 - 60 | The minute value of ON time |
65536 - 65543 | The day value (Mon to Sun) |
16777216 | Enable the setting. |
Set the OFF time of output load. Size: 4 Byte, Default Value: 8327680
Setting | Description |
---|---|
256 - 316 | The hour value of ON time |
65536 - 65543 | The day value (Mon to Sun) |
16777215 | Disable the setting. |
0 - 60 | The minute value of ON time |
16777216 | Enable the setting. |
Enables/disables the function of parameter 91 and 92. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Threshold change in wattage (in terms of wattage) to induce an automatic report. Size: 2 Byte, Default Value: 25
Setting | Description |
---|---|
0 - 60000 | The thershold value range is 0 to 60000 |
Threshold change in wattage (in terms of percentage) to induce an automatic report. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 - 100 | The thershold value range is 0 to 100 |
Hardware Platform | ZM5101 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 132 FW: 1.01:01.00 |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-17035501 |
Z-Wave Product Id | 0x016A.0x0003.0x0084 |
Switch Type | Toggle |
Firmware Updatable | Updatable by Consumer by RF |
Electric Load Type | Dimmable LEDELV (Electronic)FluorescentIncandescentInductive (e.g. Motor)LEDMLV (Magnetic) |
Z-Wave Scene Type | Scene |
Supported Meter Type | Electric Energy |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |