This is a
enter the Inclusion Mode of gateway, and press the tamper switch 3 times within 1.5s, then the PIR sensor will stay in enrollment state until successfully enrolled into network or enrollment time out after 30s.
IX30-Z-Wave is a digital micro-control intrusion detector adopting Energy Accumulation Logical Processing & Random Dynamic Time Segmentation Technology. With precise columnar Fresnel lens, IX30-Z-Wave can increase its energy receiving efficiency and sensitivity without false alarm. In conjunction with advanced software technology, it will make an accurate judgment between real intruder & interference factors that may cause false alarm. Superior ability to detect & prevent false positives.
Reset to factory default | Press the anti-tamper switch for 6 times within 2.5 seconds to restore factory settings(Please include a request to use the resetprocedure only when the primary controller is missing or inoperable) |
Inclusion | enter the Inclusion Mode of gateway, and press the tamper switch 3 times within 1.5s, then the PIR sensor will stay in enrollment state until successfully enrolled into network or enrollment time out after 30s. |
Exclusion | enter the Exclusion Mode of gateway, and press the tamper switch 3 times within 1.5s, then the PIR sensor will be removed after a period of time. |
NIF | XXXNIF |
Wakeup | a) Manual Wake-up Quickly press tamper switch once, the PIR sensor will automatically send wake-up information, and there will be 10s after wake-up to receive gateway setting information.b) Automatic Wake-up Default time of automatic wake-up is 24 hours, and there will be 10s after wake-up to receive gateway setting information, the max automatic report time = 24 hours, minimum=30min |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | It will send NOTIFICATION_REPORTto the device in Lifeline group when the PIR sensor is triggered/recovered , tamper switch is triggered / recovered. When in low battery status, PIR sensor will send BATTERY_REPORT to Lifeline group device periodically. The PIR sensor will send DEVICE_RESET_LOCALLY_NOTIFICATION to Lifeline group device when the device recovers to factory settings. |
2 | 2 | When the PIR sensor is opened, it will send BASIC SET command to control these devices in Group2. |
If there is any device under Association Group2, the door sensor will send Basic Set = value command to control that device when the door sensor is opened. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
255 | For ON/OFF Light Only |
1 - 100 | Dimmer Level |
If there is any device under Association Group2, the PIR sensor will send Basic Set = value command to Group2, and send Basic Set = 0x00 command to turn-off light after 5 x t seconds Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
1 - 24 | Turn Off Light Time |
Min set time is 5s. If the configuration is 1, that means it will eliminate alarm after 5 seconds, if t, will eliminate alarm after 5 x t seconds. Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
1 - 24 | PIR Sensor Alarm Elimination Time Configuration |
Hardware Platform | ZM5202 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 255 FW: 5.36 |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-17035481 |
Z-Wave Product Id | 0x0214.0x0002.0x0002 |
Supported Notification Types | Home Security |
Sensors | Motion/No Motion (Binary) |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |