This is a
1.Set the Z-Wave network main controller into learning mode.2.Triggering this action button.3.If the add for inclusion is successful, the LED will blink less than 5 seconds and then keep on 3 seconds. Otherwise, the LED will blink 8 seconds and then turn off, in which case you need to repeat the process from step 2.
Arrival Sensor lets you stay connected with the people who matter most to you. By placing the sensor on your keychain, in a purse, in a glove compartment, or around a pets collar, you can receive notifications when a person, pet, or car arrives and leaves home
Reset to factory default | Press and hold more than 5 seconds,led will keep on until the Z-Button is released; Arrival Sensor will send Device_Reset_Locally to the main controller and exclude from the Z-Wave network when the Z-Button is released, this procedure will reset the Sensor to factory default.Please use this procedure only when the network primary controller is missing or otherwise inoperable. |
Inclusion | 1.Set the Z-Wave network main controller into learning mode.2.Triggering this action button.3.If the add for inclusion is successful, the LED will blink less than 5 seconds and then keep on 3 seconds. Otherwise, the LED will blink 8 seconds and then turn off, in which case you need to repeat the process from step 2. |
Exclusion | 1.Set the Z-Wave network main controller into learning mode.2.Triggering this action button.3.If the remove for exclusion, the LED will turn off within 1 second. Otherwise, the LED will blink 8 seconds and then turn off, in which case you need to repeat the process from step 2. |
NIF | XXXNIF |
Wakeup | Press the study key three times then the Arrival sensor sending Wake Up Notification to Gateway to report it was wake up. Please make sure the Arrival Sensor is added to the Z-wave network. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | 1, Configure Notification Status for 0xFF (default) send Notification when send Heartbeat and TimeEnd.2, Configuration parameter 0x0A: Send Battery Report (0xFF) when Battery lower than 10%. |
Low Battery Power Level of alarm threshold values: the value range are 10~50 for percentage, so the Battery Low Power level can setting 10%~50%. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
10 - 50 | Battery Low Power level can setting 10%~50% |
Configuration Lock function: when it was lock then the other parameters value cannot change unless this parameter. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | unlock |
1 | lock |
Reset the Z-wave network or configuration parameter. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
143165576 | Reset to factory configuration and removed the Z-wave network. |
-2013265920 | Reset Configuration parameter toConfiguration parameter default value. |
Hardware Platform | ZM5101 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 2.08 |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-17025451 |
Z-Wave Product Id | 0x0300.0x0003.0x0002 |
Firmware Updatable | Updatable by Manufacturer |
Supported Notification Types | ClockHeat Alarm |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |