This is a
In the front casing, there is button that is used to carry out include, exclude or reset factorydefault settings on PCB Board.When power is first supplied, the LED will flash on and off alternately at one second intervalswithin 5 seconds if the detector has not been added a ZWave network. Please get familiar withthe terms below before starting the operations.This product can be included and operated in any ZWave network with other ZWave certifieddevices from other manufacturers and/or other applications. All nonbattery operated nodeswithin the network will act as repeaters regardless of vendor to increase reliability of thenetwork.
Loud alarm sound (up to 105dB) with flashing LED's when triggered.Mounts anywhere- it's wireless and 100% battery powered with 1-year battery life (2 CR123A Batteries Included).1.Make sounds and lighting when alarm is triggered2.Compatible with 300 series and 500 series.3.Range:Up to 50m outdoor :Up to 30m indoor 4.Standby current :87uA5. Continuous work :1400 times
Reset to factory default | Reset procedure will delete all information on the ZWave network and ZWave controller orZWave Gateway, and restore the siren to factory default settings.1. Remove the device cover.2. Make sure the siren is powered.3. Press and hold the button for 10 seconds, led will blink once.4. Release the button.Note: to use the reset procedure only when the primary controller is missing or inoperable. |
Inclusion | In the front casing, there is button that is used to carry out include, exclude or reset factorydefault settings on PCB Board.When power is first supplied, the LED will flash on and off alternately at one second intervalswithin 5 seconds if the detector has not been added a ZWave network. Please get familiar withthe terms below before starting the operations.This product can be included and operated in any ZWave network with other ZWave certifieddevices from other manufacturers and/or other applications. All nonbattery operated nodeswithin the network will act as repeaters regardless of vendor to increase reliability of thenetwork. |
Exclusion | 1. Remove the siren cover.2. Make sure the siren is powered.3. Set ZWave controller or ZWave gateway into inclusion mode (Refer to the controller orgateway operating manual)4. Press the button three times within 1.5 second, the device will enter inclusion mode. And theLED will flash on and off alternately five times.Note: If siren has not been added to Zwave network, the siren will enter inclusion modeautomatically when it is powered on. You should let the controller enter into inclusion firstbefore power on the siren in order to run this function. |
NIF | XXXNIF |
Wakeup | You can press the button once to wake up the device and send wakeup notification to controller. If press successfully, the LED will blink one time |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | GROUP 1 is lifeline service that assigned to Siren status. It enables the Siren to send reports andreadings to ZWave Controller or ZWave Gateway whenever the sensor is triggered. This GroupSupport:SWITCH_BINARY_REPORT,NOTIFICATION_REPORT,BATTERY_REPORT,DEVICE_RESET_LOCALLY_NOTIFICATION |
2 | 5 | GROUP 2 allows for Send Binary Switch Report to associated devices in this group. This GroupSupport:SWITCH_BINARY_REPORT |
3 | 5 | GROUP 3 allows for Send Notification to associated devices in this group. This GroupSupport: NOTIFICATION_REPORT |
This parameter defines the output volume when siren plays door bell music. Door Bell musicvolume is divided into 3 stages, Low (Parameter is set to 1), Middle (Parameter is set to 2), High(Parameter is set to 3). Default value is 3. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 3 | unsigned |
This Parameter defines the alarm music duration time when siren receive an alarm sensornotification report or an alarm command from controller. The duration time is divided into 5stages: Siren is not on (Parameter is set to 0), 30 second (Parameter is set to 1), 1 minute(Parameter is set to 2), 5 minute (Parameter is set to 3) and Siren is always on until battery isdead (Parameter is set to 0xFF). Default value is 2.The value for this parameter is unsigned value.Values above 127 may need to be entered as hexadecimal values or signed negative values; please consult the owner's manual of your controller for entering unsigned values. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
255 - 0 | unsigned |
0 - 3 | unsigned |
This parameter defines the door bell music duration time when siren receives a door/windowsensor notification report or an alarm command (BASIC_SET = 0x02) from controller. The doorbell music will be played always if this parameter is set to 0xFF. The door bell music will not beplayed if this parameter is set to 0. Other values are the door bell music playing duration time.Unit: Time.The value for this parameter is unsigned value.Values above 127 may need to be entered as hexadecimal values or signed negative values; please consult the owner's manual of your controller for entering unsigned values. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 255 | unsigned |
This parameter defines the output volume when siren plays alarm music. Door Bellmusic volume is divided into 3 stages, Low (Parameter is set to 1), Middle (Parameter is set to2), High(Parameter is set to 3). Default value is 1. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 3 | unsigned |
This parameter defines the alarm music index for siren play different music whenalarm occurs. There are 10 different music for user selection. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 10 | unsigned |
This parameter defines the door bell music index for siren play different music whenalarm occurs. There are 10 different music for user selection. Size: 1 Byte, Default Value: 9
Setting | Description |
---|---|
1 - 10 | unsigned |
This parameter defines the default music index, volume and the duration time forsiren on. This parameter can be selected between ALARM MUSIC and DOOR BELLMUSIC. The settings for ALARM MUSIC MODE defines by Param #1, #2 and #5. Thesettings for DOOR BELL MUSIC MODE defines by Param #3, #4 and #6.If parameter is set to 1, siren will select ALARM MUSIC MODE to play music;If parameter is set to 2, siren will select DOOR BELL MUSIC MODE to play music; Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 2 | unsigned |
This parameter defines the default led enable status when siren is on for ALARMMUSIC MODE.If parameter is set to 0, led will be disable.If parameter is set t0 1, led will be enable. When siren is on, the led will blink. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | unsigned |
This parameter defines the default led enable status when siren is on for DOOR BELLMUSIC MODE.If parameter is set to 0, led will be disable.If parameter is set t0 1, led will be enable. When siren is on, the led will blink. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | unsigned |
Hardware Platform | ZM5202 |
Device Type | Siren |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 48 FW: 2.90 |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-17025443 |
Z-Wave Product Id | 0x0258.0x0003.0x1088 |
Firmware Updatable | Updatable by Manufacturer |
Communications Protocol | Z-Wave Serial API |
Communications Connections | RS-232 (Serial) |
Z-Wave Scene Type | Scene |
Color | White |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |