Quickstart

This is a On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
If you want to manually include the device, pressthe button for 3 times to include the device.LED Status: Blue LED Solid light.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Smart Meter switch allows controlling two independentloads both via Z-Wave wirelessly and locally utilizing atraditional wall switch. The switch is no longer directlyconnected to the load but acts as input device for the inwall switch that is controlling the load. And this devicecan calculate the total power consumption in timeperiods of day, month and year. Display the values of themeasurements on the remote site.

Reset to factory default The Device Reset Locally Notification Command is used toadvertise that the device will be reset to default.Press the button 3 times in 2 sec., and hold it for morethan 3 sec.Please use this procedure only when the network primarycontroller is missing or otherwise inoperable.
Inclusion If you want to manually include the device, pressthe button for 3 times to include the device.LED Status: Blue LED Solid light.
Exclusion If you want to manually exclude the device, pressthe button for 3 times to exclude the device.LED Status: Green LED 1 sec. flashes 1 times
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Group-1:u0022Lifelineu0022.Group-1 is used to send device status (NOTIFICATION,DEVICE_RESET_LOCALLY NOTIFICATION,BASIC_REPORT,METER_REPORT) to the controller.
2 5 Group-2:u0022ON/OFF controlu0022.When the device is turned on/off, a BASIC_SET Command Class will be sent to the devices in Group-2.
3 5 Group-3:u0022Overload alarmu0022.When over loaded ,a NOTIFICATION report will be sent to the devices in Group-3.

Configuration Parameters

Parameter 1: Meter Report Time

How often to send a meter report(minute).Available configuration value:5-1092:5 minutes to 1092 minutes.
Size: 2 Byte, Default Value: 30

Setting Description
5 - 1092 How often to send a meter report(minute).

Parameter 2: Night light mode

Sets the night light mode.Available configuration value:0: Turn off the night light1: Turn on the night light
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Sets the night light mode

Parameter 3: Night light color value

Sets the night light color value.Available configuration value:0: none color1:Red2: Orange3: Green4: Blue5: Indigo6: Pink7: Light Pink
Size: 1 Byte, Default Value: 0

Setting Description
0 - 7 Sets the night light color value

Technical Data

Hardware Platform ZM5101
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 255 FW: 2.14
Z-Wave Version 6.51.09
Certification ID ZC10-17025434
Z-Wave Product Id 0x0068.0x0003.0x0006
Supported Meter Type Electric Energy
Firmware Updatable Updatable by Manufacturer
Electric Load Type ELV (Electronic)
Frequency XXfrequency
Maximum transmission power XXantenna
JapanOn/Off Power Switch