Quickstart

This is a On/Off Power Switch for Japan. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
If you want to manually include the device, pressthe button for 3 times to include the device.LED Status: Blue LED Solid light.

Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.


Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.

If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

Smart Meter switch allows controlling two independentloads both via Z-Wave wirelessly and locally utilizing atraditional wall switch. The switch is no longer directlyconnected to the load but acts as input device for the inwall switch that is controlling the load. And this devicecan calculate the total power consumption in timeperiods of day, month and year. Display the values of themeasurements on the remote site.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.

The Device Reset Locally Notification Command is used toadvertise that the device will be reset to default.Press the button 3 times in 2 sec., and hold it for morethan 3 sec.Please use this procedure only when the network primarycontroller is missing or otherwise inoperable.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

If you want to manually include the device, pressthe button for 3 times to include the device.LED Status: Blue LED Solid light.

Exclusion

If you want to manually exclude the device, pressthe button for 3 times to exclude the device.LED Status: Green LED 1 sec. flashes 1 times

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number Maximum Nodes Description
1 1 Group-1:u0022Lifelineu0022.Group-1 is used to send device status (NOTIFICATION,DEVICE_RESET_LOCALLY NOTIFICATION,BASIC_REPORT,METER_REPORT) to the controller.
2 5 Group-2:u0022ON/OFF controlu0022.When the device is turned on/off, a BASIC_SET Command Class will be sent to the devices in Group-2.
3 5 Group-3:u0022Overload alarmu0022.When over loaded ,a NOTIFICATION report will be sent to the devices in Group-3.

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.

Parameter 1: Meter Report Time

How often to send a meter report(minute).Available configuration value:5-1092:5 minutes to 1092 minutes.
Size: 2 Byte, Default Value: 30

Setting Description
5 - 1092 How often to send a meter report(minute).

Parameter 2: Night light mode

Sets the night light mode.Available configuration value:0: Turn off the night light1: Turn on the night light
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Sets the night light mode

Parameter 3: Night light color value

Sets the night light color value.Available configuration value:0: none color1:Red2: Orange3: Green4: Blue5: Indigo6: Pink7: Light Pink
Size: 1 Byte, Default Value: 0

Setting Description
0 - 7 Sets the night light color value

Technical Data

Hardware Platform ZM5101
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 255 FW: 2.14
Z-Wave Version 6.51.09
Certification ID ZC10-17025434
Z-Wave Product Id 0x0068.0x0003.0x0006
Supported Meter Type Electric Energy
Firmware Updatable Updatable by Manufacturer
Electric Load Type ELV (Electronic)
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info
  • Association V2
  • Basic
  • Configuration
  • Device Reset Locally
  • Firmware Update Md V2
  • Manufacturer Specific V2
  • Meter V3
  • Notification V4
  • Powerlevel
  • Switch Binary
  • Version V2
  • Zwaveplus Info V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall controllers.
  • Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.
  • Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.
  • Inclusion — is the process of adding new Z-Wave devices into a network.
  • Exclusion — is the process of removing Z-Wave devices from the network.
  • Association — is a control relationship between a controlling device and a controlled device.
  • Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.
  • Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.