This is a
1. Bring the Water Sensor within direct range of your controller2. Carefully remove the cover from the sensor3. Remove the plastic pull-tab from the battery slot. The LED indicator will blink slowly 5 times4. Put your Z-Wave controller into inclusion mode5. Press and release the Z-Wave button on the Water Sensor 3 TIMES quickly. The LED indicator will flash quickly6. A new water (leak) sensor will appear on your controller's device listTroubleshooting TipsIf you are unable to include the Z-Wave Water Sensor to your controller, try one of the following:- Bring the sensor closer to your hub or use a hand-held secondary controller to perform inclusion- Once in inclusion mode, press and release the Z-Wave button quickly 6-7 TIMES to ensure the command has gone through - Put your controller in EXCLUSION mode. Press and release the Z-Wave button quickly 3 TIMES, and then try adding the sensor to your network again- You may need to change the device type manually if the sensor is not recognized correctly (email us for more info: ask@getzooz.com)
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Product features:- Reliable water and leak detection- Wireless notifications and event triggers (when included to a Z-Wave gateway controller)- Built-in audio and visual alarms- Low battery alerts- Z-Wave Plus with improved 500 chip for faster and safer wireless communication- Flexible installation with 2 mounting optionsSpecifications:Model Number: ZSE30 Z-Wave Signal Frequency: 908.42 MHzPower: 1 CR2 battery (included)Power Consumption: 0.13WOperating Temperature: 32104 FRange: Up to 100 feet line of sightInstallation and Use: Indoor onlyDimensions: 2.5 x 0.9 Weight: 2 oz
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
When your networks primary controller is missing or otherwise inoperable, you may need to reset the device to factory settings manually. To complete the process, make sure the Water Sensor is powered on, then PRESS AND HOLD the Z-Wave button for AT LEAST 10 SECONDS until the LED indicator flashes ONCE. Release the button. NOTE: All previously recorded activity and custom settings will be erased from the devices memory.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device. To wakeup the device please perform the following action: If you change settings and parameters for the sensor, you may need to wake it up manually for the changes to be recorded. Press and release the Z-Wave button THREE TIMES to wake the device up. The LED indicator will flash ONCE.The sensors wake-up interval is set to 12 hours by default to save battery life. Though not recommended, you can change the wake-up interval using your controllers advanced settings if available. Minimum value: 300s (5 minutes), maximum value: 16,777,200s (around 194 days). Accepted values need to match minute intervals, so 300, 360, 420, etc.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline communication of water leak detection to Z-Wave controller. Supported command classes:NOTIFICATION_REPORT_V4BATTERY_REPORTSENSOR_BINARY_REPORT_V2DEVICE_RESET_LOCALLY_NOTIFICATION |
2 | 5 | Control command communication to associated Z-Wave devices in the network. Use parameter 7 to configure this groups settings. Supported command classes:BASIC_SET |
3 | 5 | Notifications to Z-Wave devices associated in this group. Supported command classes:NOTIFICATION_REPORT_V4 |
4 | 5 | Notifications to Z-Wave devices associated in this group. Supported command classes:SENSOR_BINARY_REPORT_V2 |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Use this parameter to set the total duration of audio and visual alarm each time water is detected. If the value is set to 0, the alarm will continue until water is no longer detected. Use parameters 24 to customize the alarm. Size: 1 Byte, Default Value: 120
Setting | Description |
---|---|
0 | alarm will continue until water is no longer detected |
1 - 255 | minutes |
Set the beeping frequency for the sensors audio alarm.The interval between beeps can be as low as 1 minute. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 255 | minutes |
Adjust the duration of the initial sound the alarm will produce after a leak is detected. Size: 1 Byte, Default Value: 60
Setting | Description |
---|---|
10 - 255 | seconds |
Adjust the duration of the beeps the alarm will sound after a leak is detected and the first long beep is produced. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
5 - 255 | seconds |
Enable or disable the audio alarm by adjusting these parameter settings. The visual alarm will NOT be disabled and the LED indicator will always light up each time water is detected. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | alarm disabled |
1 | alarm enabled |
Enable or disable water detection for the sensor by adjusting these parameter settings. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | sensor disabled |
1 | sensor enabled |
You can choose if your Water Sensor turns an associated device on or off when sending the basic set command. Use value 0 to turn the associated device OFF and value 255 to turn it ON. Adjust brightness level for a Z-Wave dimmer (Multilevel switch) by putting in any value between 1 and 99. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 | OFF |
1 - 99 | % of light |
255 | ON |
Hardware Platform | ZM5202 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 48 FW: 2.40 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-17025433 |
Z-Wave Product Id | 0x027A.0x0003.0x0085 |
Sensors | Moisture |
Color | White |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |