Quickstart
This is a
Notification Sensor for XXXQFrequencyName.
To run this device please make sure the internal battery is fully charged.
To add this device to your network execute the following action:
A Z-Wave network controller in Z-Wave terminology can be connected to the handle. If you want to use a Z-Wave network controller, you must add the handle to the network. Proceed as follows:1. Set the receiver to the inclusion mode2. With the window open, change the handle position at least six times within three seconds, causing the green LED to flash continuously;3. The handle should now be added to the Z-Wave network.4. The green LED flashes once (1 second) when the handle is included
Important safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from
Z-Wave Alliance Product
data and may be incomplete. Please refer to the
Manufacturers Manual for more information.
Product Description
The handle is used to display the opening state of the window or the window door. The system signals the opening states "vented", "open" and "closed".The handle is suitable for turning windows or balcony doors.
Reset to factory default |
Open the handle. Change window / door position at least 6 times, stopping when the window / door is open. Change the handle position at least 6 times. All this should be completed within 10 seconds.Important: Use this procedure only if the primary network controller is missing or otherwise inoperable. |
Inclusion |
A Z-Wave network controller in Z-Wave terminology can be connected to the handle. If you want to use a Z-Wave network controller, you must add the handle to the network. Proceed as follows:1. Set the receiver to the inclusion mode2. With the window open, change the handle position at least six times within three seconds, causing the green LED to flash continuously;3. The handle should now be added to the Z-Wave network.4. The green LED flashes once (1 second) when the handle is included |
Exclusion |
To remove the handle from your Z-Wave network, do the following:1. Open the window / door.2. Set the Z-Wave controller to the Exclude mode;3. With the window open, change the handle position at least six times within three seconds, causing the green LED to flash continuously;4. The handle should now be removed from the Z-Wave network.5. The red LED flashes once (1 second) if the handle has been successfully excluded. |
NIF |
XXXNIF |
Wakeup |
Normally, the handle sleeps to save batteries. He periodically wakes up (by default, once per hour) and sends a wake-up message, after which he can receive messages before he falls asleep again. The user can, e.g. For configuration purposes, request an additional wakeup notification via the following "manual wakeup" procedure:1. Open Handle and then Window / Window Door2. Change the grip position, wait until the green LED flashes and then within1 second change the grip position again3. After 2 seconds, the green LED blinks twice, the wakeup procedure starts. |
Protection |
XXXProtection |
FirmwareUpdate |
XXXFirmwareUpdate |
SetAssociation |
XXXSetAssociation |
Association Groups:
Group Number |
Maximum Nodes |
Description |
1 |
5 |
Z-Wave Plus Lifeline |
Technical Data
Hardware Platform |
ZM5101 |
Device Type |
Notification Sensor |
Network Operation |
Reporting Sleeping Slave |
Firmware Version |
HW: 30 FW: 1.00:00.01 |
Z-Wave Version |
6.61.00 |
Certification ID |
ZC10-17025414 |
Z-Wave Product Id |
0x0313.0x0001.0x0001 |
Frequency |
XXfrequency |
Maximum transmission power |
XXantenna |