This is a
Auto Inclusion:1. Put your Z-Wave controller in inclusion mode2. Carefully remove the cover from the device3. Remove the plastic pull-tab from the battery slotthe Chime will automatically enter inclusion mode for 20 seconds4. A new alarm siren / doorbell device will appear on your controller's device listManual Inclusion:1. Bring the Smart Chime within direct range of your controller2. Carefully remove the cover from the device3. Remove the plastic pull-tab from the battery slot. The LED indicator will blink slowly4. Put your Z-Wave controller in inclusion mode5. Press and release the Z-Wave button on the Smart Chime 3 TIMES quickly. The LED indicator will flash quickly6. A new alarm siren / doorbell device will appear on your controller's device list (if it connects as an on/off switch, you may need to change the device type manually. Contact us for instructions).
Product features:- Audio and visual notifications triggered by other Z-Wave devices or scheduled in your routine- Choose from 10 different sounds for chime and siren modes- Advanced configuration available- Powerful long-lasting batteries - Z-Wave Plus with improved 500 chip for faster and safer wireless communication- Small size and quick installation Specifications:Model Number: ZSE33Z-Wave Signal Frequency: 908.42 MHzPower: 2 CR123 batteries (included)Power Consumption: 2WOperating Temperature: 32104 FRange: Up to 100 feet line of sightInstallation and Use: Indoor onlyDimensions: 2.7 x 1.2 Weight: 3 oz
Reset to factory default | When your networks primary controller is missing or otherwise inoperable, you may need to reset the device to factory settings manually. To complete the process, make sure the Smart Chime is powered on, then PRESS AND HOLD the Z-Wave button for AT LEAST 10 SECONDS until the LED indicator flashes ONCE. Release the button. NOTE: All previously recorded activity and custom settings will be erased from the devices memory. |
Inclusion | Auto Inclusion:1. Put your Z-Wave controller in inclusion mode2. Carefully remove the cover from the device3. Remove the plastic pull-tab from the battery slotthe Chime will automatically enter inclusion mode for 20 seconds4. A new alarm siren / doorbell device will appear on your controller's device listManual Inclusion:1. Bring the Smart Chime within direct range of your controller2. Carefully remove the cover from the device3. Remove the plastic pull-tab from the battery slot. The LED indicator will blink slowly4. Put your Z-Wave controller in inclusion mode5. Press and release the Z-Wave button on the Smart Chime 3 TIMES quickly. The LED indicator will flash quickly6. A new alarm siren / doorbell device will appear on your controller's device list (if it connects as an on/off switch, you may need to change the device type manually. Contact us for instructions). |
Exclusion | 1. Make sure the Smart Chime is powered on and located within direct range of your Z-Wave gateway controller2. Put your Z-Wave controller in exclusion mode3. Press and release the Z-Wave button 3 TIMES quickly. The LED indicator will flash quickly 4. The Smart Chime should disappear from your controller's device listIf the first attempt is unsuccessful, please repeat the process following all steps carefully. |
NIF | XXXNIF |
Wakeup | Press and release the Z-Wave button three times. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline.Supported command classes:SWITCH_BINARY_REPORTNOTIFICATION_REPORTBATTERY_REPORTDEVICE_RESET_LOCALLY_NOTIFICATION |
2 | 5 | Status notifications to Z-Wave devices associated in this group. Supported commandclasses:SWITCH_BINARY_REPORT |
3 | 5 | Notifications to Z-Wave devices associated in this group. Supported command classes:NOTIFICATION_REPORT |
Choose from 3 volume levels for the alarm siren sound. Set volume to low, medium, or high. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 3 | Low(1), medium (2), high (3) |
Choose from 5 modes to set the duration for siren alarm:0alarm is off1alarm goes off for 30 seconds2alarm goes off for 60 seconds3alarm goes off for 5 minutes255alarm continues until battery drains Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | alarm is off |
1 | alarm goes off for 30 seconds |
2 | alarm goes off for 60 seconds |
3 | alarm goes off for 5 minutes |
255 | alarm continues until battery drains |
Choose how many times the chime should repeat the doorbell sound once triggered by a BASIC_SET alarm command from a door sensor.Values: 0chime is off, 1254 (cycles); 255chime sound continues until battery drains; 2default setting. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Chime is off |
1 - 254 | Number of cycles |
255 | chimesound continues until battery drains |
Choose from 3 volume levels for the doorbell sound. Set volume to low, medium, or high. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 3 | Low(1), medium (2), high (3) |
Choose one of the 10 different tones for alarm siren. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 10 | Alarm tones from library |
Choose one of the 10 different tones for doorbell. Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
1 - 10 | Chime tones from library |
Switch between Siren Alarm (configured by parameters 1, 2, 5, 8) and Chime / Doorbell (parameters 3, 4, 6, 9) modes.Values: 1Siren Alarm enabled; 2Chime enabled (default). Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
1 | Siren Alarm enabled |
2 | Chime enabled |
Enable or disable visual alarm for Siren mode. The LED will blink when triggered.Values: 0LED disabled; 1LED enabled (default). Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | LED disabled |
1 | LED enabled |
Enable or disable visual alarm for Chime mode. The LED will blink when triggered.Values: 0LED disabled (default); 1LED enabled. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | LED disabled |
1 | LED enabled |
Hardware Platform | ZM5202 |
Device Type | Siren |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 48 FW: 2.65 |
Z-Wave Version | 6.51.08 |
Certification ID | ZC10-17015394 |
Z-Wave Product Id | 0x027A.0x0003.0x0088 |
Color | |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |