This is a
Connect module to power supply (with temperature sensor connected - if purchased),enable add/remove mode on main controllerauto-inclusion (works for about 2 minutes after connected to power supply) orpress push button I1 three times within 3s (3 times change switch state within 3 seconds) orpress service button S (only applicable for 24 V SELV supply voltage) for more than 2 second.NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
This Z-Wave module is used for dimming the bulb or to manage the speed of a fan. The module can be controlled either through a Z-Wave network or through the wall switch. The module is designed to be mounted inside a flush mounting box, hidden behind a traditional wall switch. Module measures power consumption of bulb or fan and supports connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-wave network.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
press push button I1 fivetimes within 3s ( 5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply orpress service button S (only applicable for 24 V SELV supply voltage) for more than 6 second.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline |
2 | 16 | Basic On/Off |
3 | 16 | Start Level Change/Stop Level Change |
4 | 16 | Multilevel Set |
5 | 16 | Basic On/Off |
6 | 16 | Notification Report |
7 | 16 | Binary Sensor |
8 | 16 | Basic On/Off |
9 | 16 | Notification Report |
10 | 16 | Binary Sensor Report |
11 | 16 | Multilevel Sensor Report |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Available config. parameters (data type is 1 Byte DEC):default value 00 - mono-stable switch type (push button)button quick press turns between previous set Dimmer value and zero1 - bi-stable switch type NOTE: Switch connected to S1 terminal is a master switch. It activates the basic functionality of the Dimmer Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Mono-stable switch type (push button)button quick press turns between previous set Dimmer value and zero. |
Available config. parameters (data type is 2 Byte DEC):default value 255255 - ALL ON active, ALL OFF active.0 - ALL ON is not active, ALL OFF is not active1 - ALL ON is not active, ALL OFF active2 - ALL ON active, ALL OFF is not activeFlush Dimmer module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
255 | ALL ON active, ALL OFF active. |
0 | ALL ON is not active, ALL OFF is not active. |
1 | ALL ON is not active, ALL OFF active. |
2 | ALL ON active, ALL OFF is not active. |
Enabling I2 means that Endpoint (I2) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint. Available configuration parameters (data type is 1 Byte DEC):Endpoint device type selection:-notification sensor (1 - 6):GENERIC_TYPE_SENSOR_NOTIFICATION, SPECIFIC_TYPE_NOTIFICATION_SENSORdefault value 01 - Home Security; Motion Detection, unknown loc.2 - CO; Carbon Monoxide detected, unknownloc.3 - CO2; Carbon Dioxide detected, unknown loc.4 - Water Alarm; Water Leak detected, unknown loc.5 - Heat Alarm; Overheat detected, unknown loc.6 - Smoke Alarm; Smoke detected, unknown loc.0 - Endpoint, I2 disabled-sensor binary (9): GENERIC_TYPE_SENSOR_BINARY, SPECIFIC_TYPE_NOT_USED9 - Sensor binary NOTE1: After parameter change, first exclude module (without setting parameters to default value) then wait at least 30s and then re include the module!NOTE 2: When the parameter is set to value 9 the notifications are send for Home Security. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Endpoint, I2 disabled. |
1 | Home Security; Motion Detection, unknown loc. |
2 | CO; Carbon Monoxide detected, unknownloc. |
3 | CO2; Carbon Dioxide detected, unknown loc. |
4 | Water Alarm; Water Leak detected, unknown loc. |
5 | Heat Alarm; Overheat detected, unknown loc. |
6 | Smoke Alarm; Smoke detected, unknown loc. |
9 | Sensor binary. |
Enabling I3 means that Endpoint (I3) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint. Available configuration parameters (data type is 1 Byte DEC):Endpoint device type selection:- notification sensor (1 - 6): GENERIC_TYPE_SENSOR_NOTIFICATION, SPECIFIC_TYPE_NOTIFICATION_SENSORdefault value 01 - Home Security; Motion Detection, unknown loc.2 - CO; Carbon Monoxide detected, unknownloc.3 - CO2; Carbon Dioxide detected, unknown loc.4 - Water Alarm; Water Leak detected, unknown loc.5 - Heat Alarm; Overheat detected, unknown loc.6 - Smoke Alarm; Smoke detected, unknown loc.0 - Endpoint, I3 disabled- sensor binary (9): GENERIC_TYPE_SENSOR_BINARY, SPECIFIC_TYPE_NOT_USED9 - Sensor binary NOTE1: After parameter change, first exclude module (without setting parameters to default value) then wait at least 30s and then re include the module!NOTE 2: When the parameter is set to value 9 the notifications are send for Home Security. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Endpoint, I3 disabled. |
1 | Home Security; Motion Detection, unknown loc. |
2 | CO; Carbon Monoxide detected, unknownloc.. |
3 | CO2; Carbon Dioxide detected, unknown loc. |
4 | Water Alarm; Water Leak detected, unknown loc. |
5 | Heat Alarm; Overheat detected, unknown loc. |
6 | Smoke Alarm; Smoke detected, unknown loc. |
9 | Sensor binary. |
Available config. parameters (data type is 2 Byte DEC):default value 00 - Auto OFF disabled 1 - 32536 = 1second - 32536 seconds Auto OFF enabled with define time, step is 1 second. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Auto OFF disabled. |
1 - 32536 | 1 second - 32536 seconds Auto OFF enabled with define time, step is 1 second. |
Set value is added or subtracted to actual measured value by sensor.Available configuration parameters (data type is 2 Byte DEC):default value 3253632536 - offset is 0.0CFrom 1 to 100 - value from 0.1 C to 10.0 C is added to actual measured temperature. From 1001 to 1100 - value from -0.1C to -10.0C is subtracted to actual measured temperature. Size: 2 Byte, Default Value: 32536
Setting | Description |
---|---|
32536 | Offset is 0.0C. |
1 - 100 | value from 0.1C to 10.0C is added to actual measured temperature. |
1001 - 1100 | value from -0.1C to -10.0C is subtracted to actual measured temperature. |
Available config. parameters (data type is 2 Byte DEC):default value 00 - Auto ON disabled 1 - 32535 = 1second - 32535 seconds Auto ON enabled with define time, step is 1 second. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Auto ON disabled. |
1 - 32535 | 1 second - 32535 seconds Auto ON enabled with define time, step is 1 second. |
If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. Available configuration parameters (data type is 1 Byte DEC):default value 5 = 0,5C change0 - reporting disabled1 - 127 = 0,1C - 12,7C, step is 0,1C Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
5 | 0,5C change. |
0 | Reporting disabled. |
1 - 127 | 0,1C - 12,7C, step is 0,1C. |
Available config. parameters (data type is 1 Byte DEC):default value 00 - mono-stable switch type (push button)button quick pressturns between previous set Dimmer value and zero1 - bi-stable switch type NOTE: to enable this function, Parameter 20 or Parameter 100 has to be set. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Mono-stable switch type (push button)button quick pressturns between previous set Dimmer value and zero. |
1 | Bi-stable switch type. |
Dimming is done by push button or switch connected to I1 (by default). Enabling additional switch, dimming can be controlled by push button or switch connected to I1 and I2. Available config. parameters (data type is 1 Byte DEC):default value 00 - single push button (connected to I1)1 - additional switch (connected to I1 and I2) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Single push button (connected to I1). |
1 | Additional switch (connected to I1 and I2) |
If Double click function is enabled, a fast double click on the push button will set dimming power at maximum dimming value. Available configuration parameters (data type is 1 Byte DEC):default value 00 - double click disabled1 - double click enabled Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Double click disabled. |
1 | Double click enabled. |
Available configuration parameter (data type is 1 Byte Dec):default Value 00Unsecure Inclusion1Secure InclusionA Flush dimmer supports secure and unsecure inclusion. Even if the controller does not support security command classes, a dimmer could be included as unsecure and keep all the functionality. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unsecure Inclusion. |
1 | Secure Inclusion. |
Available config. parameters (data type is 1 Byte DEC):default value 00 - NO (normally open) input type1 - NC (normally close) input type Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | NO (normally open) input type. |
1 | NC (normally close) input type. |
Available config. parameters (data type is 1 Byte DEC):default value 00 - Flush Dimmer module saves its state before power failure (it returns to the last position saved before a power failure).1 - Flush Dimmer module does not save the state after a power failure, it returns to u0022offu0022 position. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Flush Dimmer module saves its state before power failure (it returns to the last position saved before a power failure). |
1 | Flush Dimmer module does not save the state after a power failure, it returns to "off" position. |
Available config. parameters (data type is 1 Byte DEC):default value 00 - NO (normally open) input type1 - NC (normally close) input type Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | NO (normally open) input type. |
1 | NC (normally close) input type. |
Set value means percentage, set value from 0 - 100=0% - 100%. Available configuration parameters (data type is 1 Byte DEC): default value 5 0 - reporting disabled1 - 100 = 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%.NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | Reporting disabled. |
1 - 100 | 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. |
Set value means time interval (0 - 32767) in seconds, when power report is send. Available configuration parameters (data type is 2 Byte DEC): default value 00 - reporting disabled1 - 32767 = 1 second - 32767 seconds. Reporting enabled. Power report is send with time interval set by entered value. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reporting disabled. |
1 - 32767 | 1 second - 32767 seconds. Reporting enabled. Power report is send with time interval set by entered value. |
Available config. parameters (data type is 1 Byte DEC):default value 1 = 1% (minimum dimming value)1- 98 = 1% - 98%, step is 1%. Minimum dimming values is set by entered value.NOTE: The minimum level may not be higher than the maximum level! 1% min. dimming value is defined by Z-Wave multilevel device class. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | 1% (minimum dimming value) |
1 - 98 | 1% - 98%, step is 1%. Minimum dimming values is set by entered value. |
Available config. parameters (data type is 1 Byte DEC):default value 99 = 99% (Maximum dimming value)2- 99 = 2% - 99%, step is 1%. Maximum dimming values is set by entered value.NOTE: The maximum level may not be lower than the minimum level! 99% max. dimming value is defined by Z-Wave multilevel device class. Size: 1 Byte, Default Value: 99
Setting | Description |
---|---|
99 | 99% (Maximum dimming value). |
2 - 99 | 2% - 99%, step is 1%. Maximum dimming values is set by entered value. |
Set value means time of moving the Dimmer between min. and max. dimming values by short press of push button I1 or controlled through UI (BasicSet). Available configuration parameters (data type is 2 Byte DEC):default value 100 = 1s50 - 255 = 500 mseconds - 2550 mseconds (2,55s), step is 10 mseconds Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
100 | 1s |
50 - 255 | 00 mseconds - 2550 mseconds (2,55s), step is 10 mseconds. |
Time of moving the Dimmer between min. and max dimming values by continues hold of push button I1 or associated device. Available configuration parameters (data type is 2 Byte DEC):default value 3 = 3s1- 255 = 1 second255 seconds Size: 2 Byte, Default Value: 3
Setting | Description |
---|---|
3 | 3s |
1 - 255 | 1 second255 seconds |
This parameter is used with association group 3.A receiving device SHOULD respect the start level if the Ignore Start Level bit is 0. A receiving device MUST ignore the start level if the Ignore Start Level bit is 1. Available configuration parameters (data type is 1 Byte DEC):default value 0 0 - respect start level1 - ignore start level Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Respect start level. |
1 | Ignore start level. |
This parameter is used with association group 3.The Duration field MUST specify the time that the transition should take from the current value to the new target value. A supporting device SHOULD respect the specified Duration value. Available configuration parameters (data type is 1 Byte DEC):default value 0 (dimming duration according to parameter 66)1 - 127 (from 1 to 127 seconds) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Dimming duration according to parameter 66. |
1 - 127 | From 1 to 127 seconds. |
Hardware Platform | ZM5202 |
Device Type | Light Dimmer Switch |
Network Operation | Always On Slave |
Firmware Version | 3.3.3.3.3 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-16115319 |
Z-Wave Product Id | 0x0159.0x0001.0x0051 |
Electric Load Type | Dimmable LEDELV (Electronic)Incandescent |
Supported Meter Type | Electric Energy |
Sensors | Air Temperature |
Switch Type | Push Button |
Color | Light Blue |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |