Quickstart

This is a Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.- Pull out the battery Insulator steadily.- The LED indicator will flash for 30 seconds (The PIR is warming up). During the warm up period, the PIR will not be activated. It is recommended that you stay away from the detection area during this time. After the warming period is over, the LED will turn off and the PIR will be ready for operation.- Put the Z-Wave control panel into Inclusion mode (please refer to the Z-Wave control panel manual).- Within 1.5 seconds, press the Function Button 3 times.- Refer to the operation manual of the Z-Wave gateway or control panel to complete the adding process.- Please press and release the Tamper Switch once after inclusion is completed to ensure the Gateway/Control Panel recognizes the current Tamper condition.- If the device has already been added (included) into another Z-Wave Gateway/Control Panel, or if the device is unable to be added into the current Z-Wave Gateway/Control Panel, try removing it first (see Removing Device).



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The IRP-16SL ZW is a Z-Wave motion detector that senses and reports suspicious movements to a security or home automation system. This microprocessor-controlled sensor adopts Adaptive Digital Signal Processing (ADSP) algorithms to deliver sensitive and reliable detection. It provides pet immunity up to 27 kilos (59 lbs) to eliminate false alarms caused by animals.The lithium battery-powered IRP-16SL ZW features long battery life of three years. Compatible with any Z-Wave mesh networks and devices, the IRP-16SL ZW can be flexibly incorporated into Z-Wave enabled systems for residential or commercial applications.

Reset to factory default Factory ResetFactory resetting the device will restore it to factory default settings (i.e. not included into any Z-Wave network). Please only use this procedure if the Z-Wave gateway or control panel is lost or otherwise inoperable.- Press and hold the Function Button of the device for 12 seconds to factory reset.
Inclusion This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.- Pull out the battery Insulator steadily.- The LED indicator will flash for 30 seconds (The PIR is warming up). During the warm up period, the PIR will not be activated. It is recommended that you stay away from the detection area during this time. After the warming period is over, the LED will turn off and the PIR will be ready for operation.- Put the Z-Wave control panel into Inclusion mode (please refer to the Z-Wave control panel manual).- Within 1.5 seconds, press the Function Button 3 times.- Refer to the operation manual of the Z-Wave gateway or control panel to complete the adding process.- Please press and release the Tamper Switch once after inclusion is completed to ensure the Gateway/Control Panel recognizes the current Tamper condition.- If the device has already been added (included) into another Z-Wave Gateway/Control Panel, or if the device is unable to be added into the current Z-Wave Gateway/Control Panel, try removing it first (see Removing Device).
Exclusion The device must be removed from existing Z-Wave network before being added into another.Exclusion Mode- Put the Z-Wave gateway or control panel into Exclusion mode (please refer to the Z-Wave or control panel manual).- Within 1.5 seconds, press the Function Button 3 times and the device will be removed from the Z-Wave network.
NIF XXXNIF
Wakeup This function uses the Z-Wave Wake Up Command Class. The Wake Up Command Class allows the battery-powered PIR to notify the Control Panel/Gateway that it is awake and ready to receive any queued commands. The wake up interval time period is programmed automatically according to Control Panels setting when The PIR is included. The recommended setting of the interval time is between 30 to 60 minutes.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Group 1 for LifeLine:Notification CC,V4 (COMMAND_CLASS_NOTIFICATION)Battery CC (COMMAND_CLASS_BASIC)Device Reset Locally CC
2 5 Group 2 for Basic Set:Basic CC, v2 (COMMAND_CLASS_BASIC)
3 5 Group 3 for Notification Report:Notification CC,V4 (COMMAND_CLASS_NOTIFICATION)

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 1 FW: 1.03:01.02
Z-Wave Version 6.51.09
Certification ID ZC10-16115317
Z-Wave Product Id 0x018E.0x0001.0x0002
Firmware Updatable Updatable by Professional/Technician
Sensors Motion/No Motion (Binary)
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoNotification Sensor