This is a
When the pushbutton is released after a press of (2sec
Simon Electronic Switch IO integrated by Electronic Switch that provides power Switch and Rocker that provides Z-Wave communication attributes.
Reset to factory default | When the pushbutton is released after a press of (20sec |
Inclusion | When the pushbutton is released after a press of (2sec |
Exclusion | When the pushbutton is released after a press of (2sec |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 3 | Z-Wave Plus Lifeline;Commands send to Life LineStatus Change: Command Class Basic - Basic ReportOutput Power change more than 10%:Command Class Meter - Meter Report |
Used during Association process by Simon Shortcut Switch IO to turn ON the main LED of all devices already associated to this shortcut. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Turns the main LED OFF |
255 | Turns the main LED ON |
delay from activation request until load activation.Please note that possible values are referenced in HEX format from 0x00 to 0xFF (unsigned 1 byte values).Please Refer to u0022Z-Wave Command Class Specification, A-Mu0022 --> u0022Multilevel Switch Set Commandu0022 --> u0022Duration Tableu0022 specification to lean more about these values meaning. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
128 - 254 | Delay in minutes From 1 to 127 |
0 - 127 | Delay in seconds |
Time that load performs activated after complete an activation process.Please note that possible values are referenced in HEX format from 0x00 to 0xFF (unsigned 1 byte values).Please Refer to u0022Z-Wave Command Class Specification, A-Mu0022 --> u0022Multilevel Switch Set Commandu0022 --> u0022Duration Tableu0022 specification to lean more about these values meaning. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 127 | Delay in seconds |
128 - 254 | Delay in minutes From 1 to 127 |
Configuration of Main LED as identification at 20%. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | LED OFF |
255 | LED ON at 20% of maximum level |
Locks the pushbutton and wired input actions. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unlock the direct control of load |
255 | Lock the direct control of load |
Parameters, Groups, and Z-Wave status are restored to default. (Only writable) Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
39015 | Device persorms a factoy default Reset |
delay from deactivation request until load deactivation.Please note that possible values are referenced in HEX format from 0x00 to 0xFF (unsigned 1 byte values)Please Refer to u0022Z-Wave Command Class Specification, A-Mu0022 --> u0022Multilevel Switch Set Commandu0022 --> u0022Duration Tableu0022 specification to lean more about these values meaning. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 127 | Delay in seconds |
128 - 254 | Delay in minutes From 1 to 127 |
Hardware Platform | ZM5202 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 4.18.72.15.65.15 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-16115315 |
Z-Wave Product Id | 0x0x26.0x0001.0x0000 |
Firmware Updatable | Updatable by Consumer by RF |
Neutral Wire Required | ok |
Switch Type | Push Button with Indicator |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |