This is a
The PIR sensor DCH-Z122 has PIR sensor function,based on Z-Waveâ„¢ technology.
Reset to factory default | There is a button on DCH-Z122. 1. Pressing button for about 5 seconds. 2. IDs are excluded and all settings will reset to factory default. Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable. |
Inclusion | There is a button on DCH-Z122. 1. Have Z-Waveâ„¢ Controller entered inclusion mode. 2. Pressing button once to enter the inclusion mode. 3. After add successful, the device will wake to receive the setting command from Z-Waveâ„¢ Controller about 20 seconds. |
Exclusion | There is a button on DCH-Z122. 1. Have Z-Waveâ„¢ Controller entered exclusion mode. 2. Pressing button once to enter the exclusion mode. |
NIF | XXXNIF |
Wakeup | There is a button on DCH-Z122. Press the button once, the device will awake 10 seconds. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 8 | Z-Wave Plus Lifeline |
2 | 8 | light control |
The Interval time for auto report the battery level. 0 means turn off auto report battery. The default value is 12.The tick time can setting by the configuration NO.20. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | The interval time for auto report the battery level. |
Setting the BASIC command value to turn on the light. -1(0xFF) means turn on the light. For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light. Caution: The range is from 0x00 to 0xFF using hexadecimal notation. Size: 1 Byte, Default Value: -1
Setting | Description |
---|---|
-128 - 127 | Basic command value to turn on the light. |
The interval time for auto report each tick. Setting this configuration will effect configuration NO.10. The unit is 1 minute. Caution 1:Setting to 0 means turn off all auto report function. Caution 2:The range is from 0x00 to 0xFF using hexadecimal notation. Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
-128 - 127 | The interval time for auto report each tick. |
PIR sensitivity setting. 0 means disable the PIR motion. 1 means the lowest sensitivity. 99 means the highest sensitivity. High sensitivity means can detected long distance,but if there is more noise signal in the environment, it will re-trigger too frequency. Size: 1 Byte, Default Value: 80
Setting | Description |
---|---|
0 - 99 | PIR sensitivity setting. |
Multisensor function switch.Using bit to control. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
16 | Disable delay 5 seconds to turn off the light,when door/window closed.(1:Disable, 0:Enable) |
32 | Disable auto turn off the light,after door/window opened to turn on the light.(1:Disable, 0:Enable) |
8 | When Bit2 is 0(Enable), Are the device and the lighting in the same room? 0:In the same room(Default), 1:In the different room. |
Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
2 | Enable sending motion OFF report.(0:Disable, 1:Enable) |
4 | Enable PIR suoer sensitivity mode. |
16 | Notification Type,0:Using Notification Report. 1: Using Sensor Binary Report. |
32 | Disable Multi CC in auto report.(1:Disable, 0:Enable) |
64 | Disable to report battery state when the device triggered.(1:Disable, 0:Enable) |
In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds per tick,default tick is 3(24 seconds). Setting the suitable value to prevent received the trigger signal too frequently. Also can save the battery energy. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 127 | Re-detect time |
After turn on the light,setting the delay time to turn off the lighting when the PIR motion to turn off the lighting when the PIR motion is not detected.8 seconds per tick,default tick is 4(32 seconds). 0 means never send turn off light command. Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
0 - 127 | Delay time to turn off the lighting when the PIR motion is not detected. |
Hardware Platform | SD3502 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 1.27:01.21 |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-16115304 |
Z-Wave Product Id | 0x0108.0x0002.0x0035 |
Color | White |
Sensors | Motion/No Motion (Binary) |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |