This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. There is a button on DCH-Z122. 1. Have Z-Waveâ„¢ Controller entered inclusion mode. 2. Pressing button once to enter the inclusion mode. 3. After add successful, the device will wake to receive the setting command from Z-Waveâ„¢ Controller about 20 seconds.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The PIR sensor DCH-Z122 has PIR sensor function,based on Z-Waveâ„¢ technology.

Reset to factory default There is a button on DCH-Z122. 1. Pressing button for about 5 seconds. 2. IDs are excluded and all settings will reset to factory default. Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.
Inclusion There is a button on DCH-Z122. 1. Have Z-Waveâ„¢ Controller entered inclusion mode. 2. Pressing button once to enter the inclusion mode. 3. After add successful, the device will wake to receive the setting command from Z-Waveâ„¢ Controller about 20 seconds.
Exclusion There is a button on DCH-Z122. 1. Have Z-Waveâ„¢ Controller entered exclusion mode. 2. Pressing button once to enter the exclusion mode.
NIF XXXNIF
Wakeup There is a button on DCH-Z122. Press the button once, the device will awake 10 seconds.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 8 Z-Wave Plus Lifeline
2 8 light control

Configuration Parameters

Parameter 10: Auto Report Battery Time

The Interval time for auto report the battery level. 0 means turn off auto report battery. The default value is 12.The tick time can setting by the configuration NO.20.
Size: 1 Byte, Default Value: 12

Setting Description
0 - 127 The interval time for auto report the battery level.

Parameter 2: Basic Set Level

Setting the BASIC command value to turn on the light. -1(0xFF) means turn on the light. For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light. Caution: The range is from 0x00 to 0xFF using hexadecimal notation.
Size: 1 Byte, Default Value: -1

Setting Description
-128 - 127 Basic command value to turn on the light.

Parameter 20: Auto Report Tick Interval

The interval time for auto report each tick. Setting this configuration will effect configuration NO.10. The unit is 1 minute. Caution 1:Setting to 0 means turn off all auto report function. Caution 2:The range is from 0x00 to 0xFF using hexadecimal notation.
Size: 1 Byte, Default Value: 30

Setting Description
-128 - 127 The interval time for auto report each tick.

Parameter 3: PIR Sensitivity

PIR sensitivity setting. 0 means disable the PIR motion. 1 means the lowest sensitivity. 99 means the highest sensitivity. High sensitivity means can detected long distance,but if there is more noise signal in the environment, it will re-trigger too frequency.
Size: 1 Byte, Default Value: 80

Setting Description
0 - 99 PIR sensitivity setting.

Parameter 6: Multi-Sensor Function Switch

Multisensor function switch.Using bit to control.
Size: 1 Byte, Default Value: 5

Setting Description
16 Disable delay 5 seconds to turn off the light,when door/window closed.(1:Disable, 0:Enable)
32 Disable auto turn off the light,after door/window opened to turn on the light.(1:Disable, 0:Enable)
8 When Bit2 is 0(Enable), Are the device and the lighting in the same room? 0:In the same room(Default), 1:In the different room.

Parameter 7: Customer Function


Size: 1 Byte, Default Value: 4

Setting Description
2 Enable sending motion OFF report.(0:Disable, 1:Enable)
4 Enable PIR suoer sensitivity mode.
16 Notification Type,0:Using Notification Report. 1: Using Sensor Binary Report.
32 Disable Multi CC in auto report.(1:Disable, 0:Enable)
64 Disable to report battery state when the device triggered.(1:Disable, 0:Enable)

Parameter 8: PIR Re-Detect Interval Time

In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds per tick,default tick is 3(24 seconds). Setting the suitable value to prevent received the trigger signal too frequently. Also can save the battery energy.
Size: 1 Byte, Default Value: 3

Setting Description
1 - 127 Re-detect time

Parameter 9: Turn Off Light Time

After turn on the light,setting the delay time to turn off the lighting when the PIR motion to turn off the lighting when the PIR motion is not detected.8 seconds per tick,default tick is 4(32 seconds). 0 means never send turn off light command.
Size: 1 Byte, Default Value: 4

Setting Description
0 - 127 Delay time to turn off the lighting when the PIR motion is not detected.

Technical Data

Hardware Platform SD3502
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 1 FW: 1.27:01.21
Z-Wave Version 6.51.09
Certification ID ZC10-16115304
Z-Wave Product Id 0x0108.0x0002.0x0035
Color White
Sensors Motion/No Motion (Binary)
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeNotification Sensor