This is a
1. Follow the instructions for your Z-Wave certifiedcontroller to include the smart switch to theZ-Wave network.2. Once the controller is ready to include your smartswitch, press and release the top or bottom buttonon the smart switch to include it in the network.
Transform any home into a smart home with the GE In-Wall Smart Motion Switch. This Z-Wave device replaces you current light switch using your existing wiring and provides Z-Wave wireless control of overhead lighting. The switch enables wireless control of On/OFF functions of incandescent, LED, xenon, halogen and fluorescent lighting. Not only does it act as a switch but the GE In-Wall Smart Motion Switch has a built in PIR sensor which can control the local and be set in occupancy or vacancy mode.
Reset to factory default | Press and release the top button ten times.Note: This should only be used in the event yournetworks primary controller is missing or otherwiseinoperable. |
Inclusion | 1. Follow the instructions for your Z-Wave certifiedcontroller to include the smart switch to theZ-Wave network.2. Once the controller is ready to include your smartswitch, press and release the top or bottom buttonon the smart switch to include it in the network. |
Exclusion | 1. Follow the instructions for your Z-Wave certifiedcontroller to exclude a device from the Z-Wavenetwork.2. Once the controller is ready to exclude your device,press and release the top or bottom button on thesmart switch to exclude it from the network. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
2 | 5 | Supports Basic Set and is controlled with the local load. |
3 | 5 | Supports Basic Set and is controlled by pressing the On or Off buttons. |
0=Test(5S)1=1 minute5=5 minutes15=15 minutes30=30 minutes0xFF=Disable timeout Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | Test (5s) |
1 | 1 minute |
5 | 5 minutes |
15 | 15 minutes |
30 | 30 minutes |
255 | Disable timeout |
1High2Medium3Low Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
1 | High |
2 | Medium |
3 | Low |
0disabled1enabled Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disabled |
1 | Enabled |
0disable110 secs220 secs330 secs445 secs11027 mins 15 secs(+15 seconds each adition, max.27 mins 15secs) Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Disable |
1 | 10 secs |
2 | 20 secs |
3 | 30 secs |
4 | 45 secs |
110 | 27 mins |
0 = press any button on the switch1 = press and releaseX button, then press and releaseONbutton Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Normal exclusion |
1 | Alternate exclusion |
0xFF = last dimming level Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 99 | Dim Level |
255 | Default |
1Manual2Vacancy3Occupancy Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 | Manual |
2 | Vacancy |
3 | Occupancy |
0disabled1enabled5 devices max:Group 15 devices lifelineGroup 25 lighting devicesGroup 35 lighting devices Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disabled |
1 | Enabled |
In a 3-way configuration, invert the connected Add-On Switch buttons0disabled1enabled Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disabled |
1 | Enabled |
0disabled1enabled Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Hardware Platform | ZM5101 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 255 FW: 5.56 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-16105294 |
Z-Wave Product Id | 0x0063.0x494D.0x3032 |
Neutral Wire Required | ok |
Sensors | Motion/No Motion (Binary) |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |