Quickstart

This is a Multilevel Sensor for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Set your primary controller into inclusion mode.Press and release the "Install" button on the sensor.The "Status" LED will blink rapidly for 3 seconds indicating successful inclusion into the network.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The Remote Temperature and Humidity sensor is a Z-Wave Plus multilevel, battery-powered, routing sensor that measures and reports indoor temperature and relative humidity.The reporting intervals and thresholds for the indoor temperature, indoor humidity and battery are configurable.The wakeup interval is also configurable.

Reset to factory default Press and hold Install button for 10 seconds.Factory Reset should only be used if the primary controller is missing or inoperable.
Inclusion Set your primary controller into inclusion mode.Press and release the "Install" button on the sensor.The "Status" LED will blink rapidly for 3 seconds indicating successful inclusion into the network.
Exclusion Set your primary controller into exclusion mode.Press and release the "Install" button on the sensor.The "Status" LED will blink rapidly for 3 seconds indicating successful exclusion from the network.
NIF XXXNIF
Wakeup A triple press of the "Install" button wakes the device up, and it will send a WAKE_UP_NOTIFICATION and a Battery Report (if on a network).A single press of "Install" button will wake the device up, and it will send out a Node Information Frame.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus Lifeline:COMMAND_CLASS_BATTERY, BATTERY_REPORTCOMMAND_CLASS_SENSOR_MULTILEVEL, SENSOR_MULTILEVEL_REPORTCOMMAND_CLASS_DEVICE_RESET_LOCALLY, DEVICE_RESET_LOCALLY_NOTIFICATION
2 5 Temperature reports from:COMMAND_CLASS_ SENSOR_MULTILEVEL, SENSOR_MULTILEVEL_REPORT
3 5 Humidity reports from:COMMAND_CLASS_ SENSOR_MULTILEVEL, SENSOR_MULTILEVEL_REPORT
4 5 Temperature driven BASIC_SETs from:COMMAND_CLASS_BASIC, BASIC_SET
5 5 Humidity driven BASIC_SETs from:COMMAND_CLASS_BASIC, BASIC_SET
6 5 BATTERY_REPORT sent when sent to Lifeline:COMMAND_CLASS_BATTERY, BATTERY_REPORT

Configuration Parameters

Parameter 1: Battery Report Interval

Time between Battery Reports in hours
Size: 1 Byte, Default Value: 0

Setting Description
0 Disabled
1 - 127 Hours, unsigned

Parameter 10: Group2 Temp Threshold

Group2 - temperature delta auto-send threshold (how many degrees change from the last auto-send)
Size: 1 Byte, Default Value: 1

Setting Description
1 - 5 Degrees, unsigned

Parameter 11: Group2 Temp Interval

Group2 - periodic temperature send interval (minutes)
Size: 1 Byte, Default Value: 0

Setting Description
0 Disabled
1 - 120 Minutes, unsigned

Parameter 12: Basic Set ON Above RH

Send Basic Set ON above humidity
Size: 1 Byte, Default Value: 0

Setting Description
0 Disabled
1 - 100 %, unsigned

Parameter 13: Basic Set ON Below RH

Send Basic Set ON below humidity
Size: 1 Byte, Default Value: 0

Setting Description
0 Disabled
1 - 100 %, unsigned

Parameter 14: Basic Set OFF Above RH

Send Basic Set OFF above humidity
Size: 1 Byte, Default Value: 0

Setting Description
0 Disabled
1 - 100 %, unsigned

Parameter 15: Basic Set OFF Below RH

Send Basic Set OFF below humidity
Size: 1 Byte, Default Value: 0

Setting Description
0 Disabled
1 - 100 %, unsigned

Parameter 16: Group1 RH Threshold

Group1 - humidity delta auto-send threshold (how much % change from the last auto-send)
Size: 1 Byte, Default Value: 5

Setting Description
5 - 50 %, unsigned

Parameter 17: Group1 RH Interval

Group1 - periodic humidity send interval (minutes)
Size: 1 Byte, Default Value: 0

Setting Description
0 Disabled
1 - 120 Minutes, unsigned

Parameter 18: Group3 RH Threshold

Group3 - humidity delta auto-send threshold (how much % change from the last auto-send)
Size: 1 Byte, Default Value: 5

Setting Description
5 - 30 %, unsigned

Parameter 19: Group3 RH Interval

Group3 - periodic humidity send interval (minutes)
Size: 1 Byte, Default Value: 0

Setting Description
0 Disabled
1 - 120 Minutes, unsigned

Parameter 2: Basic Set ON Above Temp

Send Basic Set ON above temp
Size: 1 Byte, Default Value: 121

Setting Description
121 Disabled
-40 - 120 Fahrenheit

Parameter 20: Basic Set Option

Basic Set options for Temp and Humidity
Size: 1 Byte, Default Value: 1

Setting Description
1 Enable Registers 2, 5, 12, 15
2 Enabled Registers 2, 5, 13, 14
3 Enable Registers 3, 4, 12, 15
4 Enabled Registers 3, 4, 13, 14

Parameter 21: Temp Offset

Temperature offset
Size: 1 Byte, Default Value: 0

Setting Description
-7 - 7 Degrees

Parameter 22: Humidity Offset

Humidity Offset
Size: 1 Byte, Default Value: 0

Setting Description
-7 - 7 %

Parameter 3: Basic Set ON Below Temp

Send Basic Set ON below temp
Size: 1 Byte, Default Value: 121

Setting Description
121 Disabled
-40 - 120 Fahrenheit

Parameter 4: Basic Set OFF Above Temp

Send Basic Set OFF above temp
Size: 1 Byte, Default Value: 121

Setting Description
121 Disabled
-40 - 120 Fahrenheit

Parameter 5: Basic Set OFF Below Temp

Send Basic Set OFF below temp
Size: 1 Byte, Default Value: 121

Setting Description
121 Disabled
-40 - 120 Fahrenheit

Parameter 6: Basic Set Attempts

Make multiple attempts for all Basic Set Commands.Number of extra attempts sent every minute after first send.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disabled
1 - 5 Number of extra attempts, unsigned

Parameter 7: Temp Units

Temperature Units
Size: 1 Byte, Default Value: 1

Setting Description
0 Celsius
1 Fahrenheit

Parameter 8: Group1 Temp Threshold

Group1 - temperature delta auto-send threshold (how many degrees changed from the last auto-send)
Size: 1 Byte, Default Value: 1

Setting Description
1 - 20 Degrees, unsigned

Parameter 9: Group1 Temp Interval

Group1 - periodic temperature send interval (minutes)
Size: 1 Byte, Default Value: 0

Setting Description
0 Disabled
1 - 120 Minutes, unsigned

Technical Data

Hardware Platform ZM5202
Device Type Multilevel Sensor
Network Operation Reporting Sleeping Slave
Firmware Version 2.1.28
Z-Wave Version 6.51.07
Certification ID ZC10-16105290
Z-Wave Product Id 0x01 7.0x52 5.0x54 3
Color White
Sensors Air TemperatureHumidity
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoMultilevel Sensor