This is a
1. Have Z-Wave Controller entered inclusion mode.2. Rotate to area A and then press button three times within 1.5 seconds to enter the inclusion mode.3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds.
This device is a multiple functions button switch. It is able toswitch the appliances on/off or adjust the percentage of dimmer.The well designed wall bracket andmagnetic back let the switch can be fixed on the wall. This productcan be included and operated in any Z-Wavenetworkwith other Z-Wavecertified devices from other manufacturers and/or other applications.
Reset to factory default | Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.1. Rotate to area A and then press button four times within 1.5 seconds and do not release the button in the 4 thpressed, and the red LED will light ON.2. After the red LED goes out, release the button within 2 seconds.3. IDs are removed and all settings will reset to factory default. |
Inclusion | 1. Have Z-Wave Controller entered inclusion mode.2. Rotate to area A and then press button three times within 1.5 seconds to enter the inclusion mode.3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds. |
Exclusion | 1. Have Z-WaveController entered exclusion mode.2. Rotate to area A and then press button three times within 1.5 seconds toenter the exclusion mode. Node ID has been removed. |
NIF | XXXNIF |
Wakeup | After the device adding to the network, it will wake-up once per day in default. When it wake-up it will broadcast the Wake Up Notification messagetothenetwork,andwake-up20secondsforreceivethe setting commands. The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours. And the interval step is 30 minutes. If the user want to wake-up the device immediately, please rotate to area A and then press the button once. The device will wake-up 10 seconds. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 8 | Z-Wave Plus Lifeline |
2 | 8 | ON/OFF Light |
Control the value represented by the left-side in area D. E.g. Setting this configuration to 0x0F means range of Command Basic Set value start from 0x0F. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 99 | basic set value of OFF from 0~99 |
The interval time for auto re-porting the Battery level. 0 means turn off auto report battery. The default value is 12. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
1 - 127 | interval time for auto re-porting battery level |
Control the value represented by the right-side in area D. E.g. Setting this configuration to 0x1E means range of Command Basic Set value start from 0x1E. Size: 1 Byte, Default Value: 99
Setting | Description |
---|---|
0 - 99 | basic set value of ON from 0~99 |
Dimmer setting method.0 : Auto send Command Basic Set after rotating.1 : Send Command Basic Set by touching key after rotating Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Auto send Command Basic Set after rotating. |
1 | Send Command Basic Set by touching key after rotating |
Hardware Platform | SD3502 |
Device Type | Wall Controller |
Network Operation | Portable Slave |
Firmware Version | HW: 1 FW: 1.08:01.06 |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-16105272 |
Z-Wave Product Id | 0x0249.0x0002.0x0001 |
Z-Wave Scene Type | |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |