Quickstart
This is a
Notification Sensor for XXXQFrequencyName.
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
-Click [Add] icon in Z-Wave PC Controller Program.-Press the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second.-If Inclusion Process is successful, Green led will turn off.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from
Z-Wave Alliance Product
data and may be incomplete. Please refer to the
Manufacturers Manual for more information.
Product Description
The smart smoke sensor detects smoke, and sends an alarm signals to alertof danger.When the smart smoke sensor detects smoke, it will send an alarm notification to your gateway through wireless Z-Wave communication protocol.Then the gateway will send the notification to the server, the server interprets the signal and transfers the signal to users' APP. The smart smoke sensor has high stabilityand sensitivity,which will alert house of fire effectively.
Reset to factory default |
-Long press Net_Button while installing batteries in HS1SA-Z. - Device Reset Locally notification is Transmitted.-Please use this procedure only when the network primary controller is missing or otherwise inoperable. |
Inclusion |
-Click [Add] icon in Z-Wave PC Controller Program.-Press the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second.-If Inclusion Process is successful, Green led will turn off. |
Exclusion |
-Click [Remove] icon in Z-Wave PC Controller Program-Press the Net_Button 3 times within 1.5s -If Exclusion Process is successful, Green led is Blinking 6 times, then turn off. |
NIF |
XXXNIF |
Wakeup |
-Wake up Notification is transmitted every 24 hours by default.-Wake up Notification is transmitted after Notification Report is Transmitted |
Protection |
XXXProtection |
FirmwareUpdate |
XXXFirmwareUpdate |
SetAssociation |
XXXSetAssociation |
Association Groups:
Group Number |
Maximum Nodes |
Description |
1 |
1 |
Association group 1: Lifeline association groupInclude command classes: Battery report, Notification report, and Device Reset Locally notification, Binary report. |
2 |
5 |
Association group 2: Root Device group(Binary Sensor)Binary Sensor Command Class: Compatible with 300 series1-Binary Sensor reports status of smoke or no smoke via Lifeline.2-When the sensor detects status change between smoke and no smoke, the device will be triggered. |
3 |
5 |
Association group 3: Root Device group(Notification)1-Notification reports reports status of detect smoke or no smoke via Lifeline.2-When the sensor detects status change between smoke and no smoke, the device will be triggered. |
Technical Data
Hardware Platform |
ZM5202 |
Device Type |
Notification Sensor |
Network Operation |
Reporting Sleeping Slave |
Firmware Version |
HW: 255 FW: 1.10 |
Z-Wave Version |
6.51.08 |
Certification ID |
ZC10-16095242 |
Z-Wave Product Id |
0x0260.0x8002.0x1000 |
Communications Connections |
Ethernet (Wireless/WiFi) |
Color |
White |
Outdoor Use |
ok |
IP (Ingress Protection) Rated |
ok |
Firmware Updatable |
Not Updatable |
Communications Protocol |
Z-Wave Serial API |
Frequency |
XXfrequency |
Maximum transmission power |
XXantenna |