This is a
Adding to a Network:1. With your Controller in Discovery or Add Mode, tap the switch. The LED will blink slowly when in ADD Mode.2. You should see an indication on your Controller that the device was added to the network and the LED will stop blinking.3. The device will appear in the list of Switches. It should display as a switch.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
The WD500Z5-1 is an in-wall lighting dimmer switch designed to operate with LED, halogen and incandescent lights.Not only can this switch control the connected load, with Central Scene support it can run up to 6 scenes created by the Hub it is the most versatile Home Automation light switch available. With OTA upgrading supported, this light switch may be the last one ever installed in a home.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
To Reset Unit (If Required):Use only in the event that your primary Controller is lost or otherwise inoperable, to reset the GoControl Dimmer and clear all network information, follow these steps:1. Tap the top of the switch five (5) times.2. Press and hold the bottom of the switch for 15 seconds. The LED will increasingly blink faster to indicate that a Reset is taking place.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
The Dim Timer sets how fast the dim steps happen in a local dimmable device Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 255 | # - Dim Remote On/Off Time in mS |
This value indicates how many levels the dimmer will change in all devices when an ALL ON or ALL OFF command is transmitted Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 99 | Dim Remote On/Off Steps |
The Dim ALL On/Off Timer sets how fast the dim steps happen in all devices when an ALL ON or ALL OFF command is transmitted Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 255 | # - Dim Remote On/Off Time in mS |
Control the operation of the LED function, Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 4 | 0 - LED OFF when the load is on, and ON when the load is off.1 - LED ON when the load is on, and OFF when the load is off.2 - LED is always on.3 - LED is always off.4 - LED blinks during RF transmissions from or to the device. |
To change the top of the switch to OFF and the bottom of the switch ON. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | 0 - Top of switch is ON, bottom of switch is OFF.1 - Bottom of switch is ON, top of switch is OFF |
The Start Level sent in a Dim command can be ignored or not. Typically the dim levelshould start from the current level and dim from there instead of suddenly changing to the Start Level and then dimming. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | 0 - Use the Start Level in the Dim Command.1 - Ignore the Start Level in the Dim Command |
This value indicates how many levels the dimmer will change a remote dimmable device each time the Dim Timer expires. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 99 | Dim Remote On/Off Steps |
The Dim Timer sets how fast the dim steps happen in a remote dimmable device Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 255 | # - Dim Remote On/Off Time in mS |
This value indicates how many levels the dimmer will change the local dimmable device each time the Dim Timer expires. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 255 | Dim Remote On/Off Steps |
Hardware Platform | ZM5202 |
Device Type | Light Dimmer Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.13 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-16095223 |
Z-Wave Product Id | 0x014F.0x5744.0x3530 |
Color | White |
Electric Load Type | Dimmable LEDIncandescent |
Neutral Wire Required | ok |
Switch Type | Decorator Paddle Push with Indicator |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |