Schnellstart

Dies ist ein Z-Wave Gerät vom Typ Schalter (Ein/Aus) für Anwendung in Australien, NZL, Brasilien, etc.. Das Gerät bitte mit dem Stromnetz verbinden, um es nutzen zu können. Um dieses Gerät zu einem Z-Wave Netz hinzuzufügen, führen Sie die folgende Aktion durch:
1)Switch off the mains voltage (disable the fuse).2)Place the Switch 2 within the direct range of your Z-Wave controller. 3)Connect the device in accordance with one of the diagrams attached in the manual.4)After verifying correctness of the connection switch on the mains voltage.5)Identify the S1 switch or the B-button (located on the devices housing). 6)Set the main controller in (security/non-security) add mode (see the controllers manual). 7)Quickly, three times press the S1 switch or the B-button. 8)Wait for the adding process to end. 9)Successful adding will be confirmed by the Z-Wave controllers message.

Achtung: Dieses Handbuch wurde automatisch aus verfügbaren Daten der Z-Wave Alliance Produktdatenbank erzeugt und kann unvollständig sein. Für weitere Informationen steht das Original-Handbuch des Herstellers bereit.


Wichtige Sicherheitshinweise

Bitte lesen Sie diese Anleitung sorgfältig durch. Die in dieser Anleitung festgelegten Empfehlungen nicht zu befolgen, kann gefährlich sein oder gegen das Gesetz verstoßen. Der Hersteller, Importeur, Vertreiber und Verkäufer haftet für keinen Verlust oder Schaden, der durch die Nichtbeachtung der Vorschriften in dieser Anleitung oder anderen Materialien entsteht. Verwenden Sie dieses Gerät nur zu dem vorgesehenen Gebrauch. Beachten Sie die Entsorgungshinweise. Elektronische Geräte jeglicher Art und Batterien dürfen nicht ins Feuer geworfen oder in die Nähe von offenen Wärmequellen gebracht werden.

Was ist Z-Wave?

Z-Wave ist der internationale Funkstandard zur Kommunikation von Geräten im intelligenten Haus. Dies ist ein Z-Wave Gerät und nutzt die im Quickstart angegebene Funkfrequenz.

Z-Wave ermöglicht eine sichere und stabile Kommunikation indem jede Nachricht vom Empfänger rückbestätigt wird (Zweiwege-Kommunikation) und alle netzbetriebenen Geräte Nachrichten weiterleiten (Routing) können, wenn eine direkte Funkbeziehung zwischen Sender und Empfänger gestört ist.

Dank Z-Wave können Produkte unterschiedlicher Hersteller miteinander in einem Funknetz verwendet werden. Damit ist auch dieses Produkt mit beliebigen anderen Produkten anderer Hersteller in einem gemeinsamen Z-Wave Funknetz einsetzbar.

Wenn ein Gerät die spezielle sichere Kommunikation unterstützt dann wird es immer dann mit einem anderen Gerät sicher kommunizieren, wenn dieses Gerät auch eine sichere Kommunikation unterstützt. Ansonsten wird aus Kompatibilitätsgründen auf einen normalen Kommunikation umgeschaltet.

Weitere Informationen wie Produktneugkeiten, Tutorials, Supportforen etc. erhalten Sie auf www.zwave.de.

Produktbeschreibung

The remotely operated FIBARO Single Switch 2 is designed to turn electrical devices on and off and to measure their power and energy consumption. The compact size of the device makes it the world's smallest of its type and allows for the product to be installed in wall switch boxes or housings. FIBARO Single Switch 2 can be controlled either via Z-Wave network or with a wall switch through a direct connection.

Vorbereitung auf die Installation des Gerätes

Bitte lesen Sie die Benutzeranleitung bevor Sie das Gerät in Betrieb nehmen.

Damit ein Z-Wave zu einem neuen Netz hinzugefügt werden kann muss es sich im Auslieferungs- oder Reset-Zustand befinden. Im Zweifel ist es sinnvoll, eine Exklusion durchzuführen, um das Gerät ganz sicher in diesem Zustand zu bringen. Diese Exklusion kann von jedem beliebigen Z-Wave Controller durchgeführt werden.

Zurücksetzen in den Auslieferungszustand

Dieses Gerät kann auch ohne Hilfe eines Controller in den Reset-Zustand zurückgeführt werden. Dies sollte jedoch nur dann gemacht werden wenn der Primärcontroller des Z-Wave-Netzes nicht mehr verfügbar oder defekt ist.

Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user configuration will be deleted. In order to reset the device:1)Switch off the mains voltage (disable the fuse).2)Remove the Switch 2 from the wall switch box.3)Switch on the mains voltage.4)Press and hold the B-button to enter the menu.5)Wait for the visual LED indicator to glow yellow.6)Quickly release and click the B-button again.7)After few seconds the device will be restarted, which is signalled with the red LED indicator colour.Use reset procedure only if the primary controller is missing or inoperable.

Sicherheitswarnung für netzbetriebene Geräte

Achtung: Je nach nationalen Sicherheitsnormen kann es nur autorisierten und/oder ausgebildeten Techniker erlaubt sein, elektrische Installationen am Spannungsnetz vorzunehmen. Bitte informieren Sie sich vor der Installation über die Rechtslage.

Hinzufügen/Entfernen des Gerätes (Inklusion/Exclusion)

Im Auslieferungszustand ist das Gerät mit keinem Z-Wave-Netz verbunden. Damit es mit anderen Z-Wave Geräten kommunizieren kann, muss es in ein bestehendes Z-Wave Netz eingebunden werden. Dieser Prozess wird bei Z-Wave Inklusion genannt. Geräte können Netzwerke auch wieder verlassen. Dieser Prozess heißt bei Z-Wave Exklusion. Beide Prozesse werden von einem Controller gestartet, der dazu in einen Inklusion- bzw. Exklusion-Modus geschaltet werden muss. Das Handbuch des Controllers enthält Informationen, wie er in diese Modi zu schalten ist. Erst wenn der Controller des Z-Wave Netzes im Inclusion-Modus ist, können Geräte hinzugefügt werden. Das Verlassen des Netzes durch Exklusion führt zum Rücksetzen dieses Gerätes in den Auslieferungszustand.

Inklusion

1)Switch off the mains voltage (disable the fuse).2)Place the Switch 2 within the direct range of your Z-Wave controller. 3)Connect the device in accordance with one of the diagrams attached in the manual.4)After verifying correctness of the connection switch on the mains voltage.5)Identify the S1 switch or the B-button (located on the devices housing). 6)Set the main controller in (security/non-security) add mode (see the controllers manual). 7)Quickly, three times press the S1 switch or the B-button. 8)Wait for the adding process to end. 9)Successful adding will be confirmed by the Z-Wave controllers message.

Exklusion

1)Place the Switch 2 within the direct range of your Z-Wave controller.2)Identify the S1 switch or the B-button (located on the devices housing).3)Set the main controller in remove mode (see the controllers manual).4)Quickly, three times press the S1 switch or the B-button.5)Wait for the removing process to end.6)Successful removing will be confirmed by the Z-Wave controllers message

Kommunikation zu einem schlafenden Gerät (Wakeup)

Das Gerät ist batteriegespeist und damit in der Regel in einem Tiefschlafmodus um Strom zu sparen. Im Tiefschlafmodus kann das Gerät keine Funksignale empfangen. Daher wird ein (statischer) Controller benötigt, der netzgespeist und damit immer funkaktiv ist. Dieser Controller - zum Beispiel ein IP-Gateway - verwaltet eine Nachrichten-Mailbox für dieses batteriegespeiste Gerät, in dem Nachrichten an dieses Gerät zwischengespeichert werden. Ohne einen solchen statischen Controller wird die Nutzung dieses batteriebetriebenen Gerätes sehr schnell zur Entladung der Batterie führen oder die Nutzung ist komplett unmöglich.

Dieses Gerät weckt regelmäßig auf, meldet dies durch Aussenden einer sogenannten Wakeup-Notifikation und leert dann seine Mailbox im statischen Controller. Dafür muss bei der Inclusion die Node-ID des Controllers und ein Aufweckinterval definiert werden. Erfolgt die Inklusion durch einen statischen Controller wie zum Beispiel ein IP-Gateway, wird dieser Controller diese Konfiguration automatisch erledigen und in der Regel eine Nutzerschnittstelle anbieten, um das Aufweck-Interval den Nutzerbedürfnissen anzupassen. Das Aufweckinterval ist ein Kompromiss zwischen maximaler Batterielaufzeit und minimaler Reaktionszeit des batteriegespeisten Gerätes.

Um das Gerät manuell aufzuwecken, führen Sie die folgende Aktion durch: The FIBARO Single Switch 2 is powered with mains voltage so it is always awake.

Einige Hinweise bei Problemen

Die folgenden kleinen Hinweise können bei Problemen im Z-Wave Netz helfen.

  1. Stellen Sie sicher, daß sich das neue Gerät im Auslieferungszustand befindet. Im Zweifel lieber noch mals eine Exclusion ausführen.
  2. Wenn ein Gerät keine Verbindung aufbaut, prüfen Sie , ob Controller und neues Gerät auf der gleichen Funkfrequenz (Länderkennung) arbeiten.
  3. Entfernen Sie nicht mehr vorhandene Geräte als allen Assoziationsgruppen. Ansonsten werden Sie erhebliche Verzögerungen bei der Kommandoausführung spüren.
  4. Nutzer Sie niemals schlafende Batteriegeräte ohne Zentralsteuerung.
  5. FLIRS-Geräte dürfen nicht gepollt werden.
  6. Stellen Sie sicher, daß Sie genügend netzbetriebene Geräte haben, um die Vorteile der Funkvermaschung zu nutzen.

Assoziation - Geräte steuern sich untereinander

Z-Wave Geräte können andere Geräte direkt steuern. Diese direkte Steuerung heißt in Z-Wave Assoziation. In den steuernden Geräten muss dazu die Geräte-ID des zu steuernden Gerätes hinterlegt werden. Dies erfolgt in sogenannten Assoziationsgruppen. Eine Assoziationsgruppe ist immer an ein Ereignis im steuernden Gerät gebunden (Tastendruck oder Auslösen eines Sensors). Bei Eintritt dieses Ereignisses wird an alle in einer Assoziationsgruppe hinterlegten Geräte ein Steuerkommando - meist ein BASIC SET - gesendet.

Assoziationsgruppen:

Gruppen-Nummer Max. Anzahl Geräte Beschreibung
1 1 Lifeline reports the device status and allows for assigning single device only (main controller by default).
2 5 On/Off (S1) is assigned to switch connected to the S1 terminal (uses Basic command class).
3 5 Dimmer (S1) is assigned to switch connected to the S1 terminal (uses Switch Multilevel command class).
4 5 On/Off (S2) is assigned to switch connected to the S2 terminal (uses Basic command class).
5 5 Dimmer (S2) is assigned to switch connected to the S2 terminal (uses Switch Multilevel command class).

Configuration Parameters

Z-Wave Produkte können direkt nach der Inklusion im Netz verwendet werden. Durch Konfigurationseinstellungen kann das Verhalten des Gerätes jedoch noch besser an die Anforderungen der Anwendung angepasst und zusätzliche Funktionen aktiviert werden.

WICHTIG: Manche Steuerungen erlauben nur die Konfiguration von vorzeichenbehafteten Werten zwischen -128 und 127. Um erforderliche Werte zwischen 128 und 255 zu programmieren, muss der gewünschte Wert minus 256 eingegeben werden. Beispiel: um einen Parameter auf einen Wert von 200 zu setzen, müsste der Wert 200-256 = -56 eingegeben werden, wenn nur positive Werte bis 128 akzeptiert werden. Bei Werten von 2 Byte Länge wird die gleiche Logik angewandt: Werte über 32768 werden als negative Werte angegeben.

Parameter 10: First channel - operating mode

This parameter allows to choose operating for the 1st channel controlled by the S1 switch.0 - standard operation1 - delay ON function2 - delay OFF function3 - auto ON function4 - auto OFF function5 - flash function
Grösse: 1 Byte, Voreingestellt: 0

Wert Beschreibung
1 delay ON function
5 flash function
4 auto OFF function
3 auto ON function
2 delay OFF function
0 standard operation

Parameter 11: First channel - reaction to switch for delay/auto ON/OFF modes

This parameter determines how the device in timed mode reacts to pushing the switch connected to the S1 terminal.0 - cancel mode and set target state1 - no reaction to switch - mode runs until it ends2 - reset timer - start counting from the beginning
Grösse: 1 Byte, Voreingestellt: 0

Wert Beschreibung
1 no reaction to switch - mode runs until it ends
2 reset timer - start counting from the beginning
0 cancel mode and set target state

Parameter 12: First channel - time parameter for delay/auto ON/OFF modes

This parameter allows to set time parameter used in timed modes.0 (0.1s), 1-32000 (1-32000s, 1s step) - time parameter
Grösse: 2 Byte, Voreingestellt: 50

Wert Beschreibung
0 0.1s
1 - 32000 1-32000s, 1s step

Parameter 13: First channel - pulse time for flashing mode

This parameter allows to set pulse time used in flashing mode.1-32000 (0.1-3200.0s, 0.1s step) - time parameter
Grösse: 2 Byte, Voreingestellt: 5

Wert Beschreibung
1 - 32000 (0.1-3200.0s, 0.1s step) - time parameter

Parameter 20: Switch type

This parameter as what type the device should treat the switch connectedto the S1 and S2 terminals.0 - momentary switch1 - toggle switch (contact closed - ON, contact opened - OFF)2 - toggle switch (device changes status when switch changes status)
Grösse: 1 Byte, Voreingestellt: 2

Wert Beschreibung
2 toggle switch (device changes status when switch changes status)
0 momentary switch
1 toggle switch (contact closed - ON, contact opened - OFF)

Parameter 21: Flashing mode - reports

This parameter allows to define if the device sends reports during the flashing mode.0 - the device does not send reports1 - the device sends reports
Grösse: 1 Byte, Voreingestellt: 0

Wert Beschreibung
0 the device does not send reports
1 the device sends reports

Parameter 27: Associations in Z-Wave network security mode

This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. This parameter does not apply to 1st Lifeline group.1 - 2nd group sent as secure2 - 3rd group sent as secure4 - 4th group sent as secure8 - 5th group sent as secureNOTEParameter 27 values may be combined, e.g. 1+2=3 means that 2nd & 3rd groups aresent as secure.
Grösse: 1 Byte, Voreingestellt: 15

Wert Beschreibung
4 4th group sent as secure
8 5th group sent as secure
1 2nd group sent as secure
2 3rd group sent as secure

Parameter 28: S1 switch - scenes sent

This parameter determines which actions result in sending scene assignedto them.1 - Key pressed 1 time2 - Key pressed 2 time4 - Key pressed 3 time8 - Key Hold Down and Key ReleasedNOTEParameter 28 values may be combined, e.g. 1+2=3 means that scenes for single anddouble click are sent.
Grösse: 1 Byte, Voreingestellt: 15

Wert Beschreibung
2 Key pressed 2 time
4 Key pressed 3 time
8 Key Hold Down and Key Released
1 Key pressed 1 time

Parameter 29: S2 switch - scenes sent

This parameter determines which actions result in sending scene IDs assigned to them.1 - Key pressed 1 time2 - Key pressed 2 times4 - Key pressed 3 times8 - Key Hold Down and Key ReleasedNOTEParameter 29 values may be combined, e.g. 1+2=3 means that scenes for single anddouble click are sent.
Grösse: 1 Byte, Voreingestellt: 15

Wert Beschreibung
4 Key pressed 3 times
8 Key Hold Down and Key Released
1 Key pressed 1 time
2 Key pressed 2 times

Parameter 30: S1 switch - associations sent to 2nd and 3rd association groups

This parameter determines which actions are ignored when sending commands to devices associated in 2nd and 3rd association group. All actions are active by default.1 - ignore turning ON with 1 click of the switch2 - ignore turning OFF with 1 click of the switch4 - ignore holding and releasing the switch*8 - ignore double click of the switch**NOTEParameter 30 values may be combined, e.g. 1+2=3 means that associations for turningON and OFF are not sent.NOTE*Hold and release is inactive when parameter 20 is set to 1 or 2. **Double click is inactive when parameter 20 is set to 1.
Grösse: 1 Byte, Voreingestellt: 0

Wert Beschreibung
2 ignore turning OFF with 1 click of the switch
4 ignore holding and releasing the switch*
1 ignore turning ON with 1 click of the switch
8 ignore double click of the switch**

Parameter 31: S1 switch - Switch ON value sent to 2nd and 3rd association groups

This parameter defines value sent with Switch ON command to devices associated in 2nd and 3rd association group.0-255 - sent value
Grösse: 2 Byte, Voreingestellt: 255

Wert Beschreibung
0 - 255 sent value

Parameter 32: S1 switch - Switch OFF value sent to 2nd and 3rd association groups

This parameter defines value sent with Switch OFF command to devices associated in 2nd and 3rd association group.0-255 - sent valueNOTESetting parameters31-33, 36-38 to appropriate value should result in:0 - turning off associated devices1-99 - forcing level of associated devices255 - setting associated devices to the last remembered state or turning them on
Grösse: 2 Byte, Voreingestellt: 0

Wert Beschreibung
0 - 255 sent value

Parameter 33: S1 switch - Double Click value sent to 2nd and 3rd association groups

This parameter defines value sent with Double Click command to devices associated in 2nd and 3rd association group.0-255 - sent value
Grösse: 2 Byte, Voreingestellt: 99

Wert Beschreibung
0 - 255 sent value

Parameter 35: S2 switch - associations sent to 4th and 5th association groups

This parameter determines which actions result in sending commands to devices associated in 4th and 5th association group. All actions are active by default.1 - ignore turning on with 1 click of the switch2 - ignore turning off with 1 click of the switch4 - ignore holding and releasing the switch*8 - ignore double click of the switch**NOTEParameter 35 values may be combined, e.g. 1+2=3 means that associations for turningON and OFF are not sent.NOTE*Hold and release is inactive when parameter 20 is set to 1 or 2. **Double click isinactive when parameter 20 is set to 1.
Grösse: 1 Byte, Voreingestellt: 0

Wert Beschreibung
1 ignore turning on with 1 click of the switch
4 ignore holding and releasing the switch*
8 ignore double click of the switch**
2 ignore turning off with 1 click of the switch

Parameter 36: S2 switch - Switch ON value sent to 4th and 5th association groups

This parameter defines value sent with Switch ON command to devices associated in 4th and 5th association group.0-255 - sent value
Grösse: 2 Byte, Voreingestellt: 255

Wert Beschreibung
0 - 255 sent value

Parameter 37: S2 switch - Switch OFF value sent to 4th and 5th association groups

This parameter defines value sent with Switch OFF command to devices associated in 4th and 5th association group.0-255 - sent value
Grösse: 2 Byte, Voreingestellt: 0

Wert Beschreibung
0 - 255 sent value

Parameter 38: S2 switch - Double Click value sent to 4th and 5th association groups

This parameter defines value sent with Double Click command to devices associated in 4th and 5th association group.0-255 - sent value
Grösse: 2 Byte, Voreingestellt: 99

Wert Beschreibung
0 - 255 sent value

Parameter 40: Reaction to General Alarm

This parameter determines how the device will react to General Alarm frame0 - alarm frame is ignored1 - turn ON after receiving the alarm frame2 - turn OFF after receiving the alarm frame3 - flash after receiving the alarm frame
Grösse: 1 Byte, Voreingestellt: 3

Wert Beschreibung
0 alarm frame is ignored
3 flash after receiving the alarm frame
2 turn OFF after receiving the alarm frame
1 turn ON after receiving the alarm frame

Parameter 41: Reaction to Flood Alarm

This parameter determines how the device will react to Flood Alarm frame.0 - alarm frame is ignored1 - turn ON after receiving the alarm frame2 - turn OFF after receiving the alarm frame3 - flash after receiving the alarm frame
Grösse: 1 Byte, Voreingestellt: 2

Wert Beschreibung
1 turn ON after receiving the alarm frame
0 alarm frame is ignored
3 flash after receiving the alarm frame
2 turn OFF after receiving the alarm frame

Parameter 42: Reaction to CO/CO2/Smoke Alarm

This parameter determines how the device will react to CO, CO2 or Smoke frame.0 - alarm frame is ignored1 - turn ON after receiving the alarm frame2 - turn OFF after receiving the alarm frame3 - flash after receiving the alarm frame
Grösse: 1 Byte, Voreingestellt: 3

Wert Beschreibung
1 turn ON after receiving the alarm frame
2 turn OFF after receiving the alarm frame
3 flash after receiving the alarm frame
0 alarm frame is ignored

Parameter 43: Reaction to Heat Alarm

This parameter determines how the device will react to Heat Alarm frame.0 - alarm frame is ignored1 - turn ON after receiving the alarm frame2 - turn OFF after receiving the alarm frame3 - flash after receiving the alarm frame
Grösse: 1 Byte, Voreingestellt: 1

Wert Beschreibung
2 turn OFF after receiving the alarm frame
3 flash after receiving the alarm frame
1 turn ON after receiving the alarm frame
0 alarm frame is ignored

Parameter 44: Flashing alarm duration

This parameter allows to set duration of flashing alarm mode.1-32000 (1-32000s, 1s step) - duration
Grösse: 2 Byte, Voreingestellt: 600

Wert Beschreibung
1 - 32000 1-32000s, 1s step - duration

Parameter 50: First channel - power reports

This parameter determines the minimum change in consumed power that will result in sending new power report to the main controller.0 - reports are disabled1-100 (1-100%) - change in power
Grösse: 1 Byte, Voreingestellt: 20

Wert Beschreibung
0 reports are disabled
1 - 100 change in power

Parameter 51: First channel - minimal time between power reports

This parameter determines minimum time that has to elapse before sending new power report to the main controller.0 - reports are disabled1-120 (1-120s) - report interval
Grösse: 1 Byte, Voreingestellt: 10

Wert Beschreibung
0 reports are disabled
1 - 120 1-120s - report interval

Parameter 53: First channel - energy reports

This parameter determines the minimum change in consumed energy that will result in sending new energy report to the main controller.0 - reports are disabled1-32000 (1-32000Wh) - change in energy
Grösse: 2 Byte, Voreingestellt: 100

Wert Beschreibung
0 reports are disabled
1 - 32000 1-32000 (1-32000Wh) - change in energy

Parameter 58: Periodic power reports

This parameter determines in what time interval the periodic power reports are sent to the main controller.0 - periodic reports are disabled1-32000 (1-32000s) - report interval
Grösse: 2 Byte, Voreingestellt: 3600

Wert Beschreibung
0 periodic reports are disabled
1 - 32000 1-32000s - report interval

Parameter 59: Periodic energy reports

This parameter determines in what time interval the periodic energy reports are sent to the main controller.0 - periodic reports are disabled1-32000 (1-32000s) - report interval
Grösse: 2 Byte, Voreingestellt: 3600

Wert Beschreibung
0 periodic reports are disabled
1 - 32000 1-32000s - report interval

Parameter 60: Measuring energy consumed by the device itself

This parameter determines whether energy metering should include the amount of energy consumed by the device itself. Results are being added to energy reports for first endpoint.0 - function inactive1 - function active
Grösse: 1 Byte, Voreingestellt: 0

Wert Beschreibung
1 function active
0 function inactive

Parameter 9: Restore state after power failure

This parameter determines if the device will return to state prior to the power failure after power is restored.0 - the device does not save the state prior tothe power failure and returns to off position1 - the device restores its state prior to the powerfailure
Grösse: 1 Byte, Voreingestellt: 1

Wert Beschreibung
0 the device does not save the state prior to the power failure and returns to off position
1 the device restores its state prior to the power failure

Technische Daten

Z-Wave Hardware Platform ZM5101
Gerätetyp On/Off Power Switch
Netzwerkfunktion Always On Slave
Firmware Version HW: 3 FW: 3.02
Z-Wave Version 6.51.06
Zertifizierungs-ID ZC10-16095202
Z-Wave Produkt Id 0x010F.0x0403.0x3000
Color
Frequenz XXfrequency
Maximale Sendeleistung XXantenna

Gesteuerte Kommandoklassen

  • Basic
  • Notification V5
  • Switch Multilevel V3

Erklärung einiger Z-Wave-Begriffe

  • Controller... ist ein Z-Wave-Gerät mit erweiterten Fähigkeiten zur Verwaltung eines Netzes. Dies sind in der Regel Gateways oder Fernbedienungen. Batteriegespeiste Wandschalter können auch Controller sein.
  • Slave... ist ein Z-Wave-Gerät mit erweiterten Fähigkeiten zur Verwaltung eines Netzes. Es gibt Sensoren, Aktoren und auch Fernbedienungen als Slaves.
  • Primärcontroller (engl. Primary Controller)... ist der zentrale Netzverwalter des Z-Wave-Netzes.
  • Inklusion (eng. Inclusion)... ist der Prozess des Einbindens eines neuen Gerätes ins Z-Wave-Netz.
  • Exklusion (engl. Exclusion)... ist der Prozess des Entfernens eines Gerätes aus dem Z-Wave-Netz.
  • Assoziation (engl. Association)... ist eine Steuerbeziehung zwischen einem steuernden und einem gesteuerten Gerät. Die Information dazu wird im steuernden Gerät in einer Assoziationsgruppe hinterlegt.
  • Wakeup Notifikation (engl. Wakeup Notification) ... ist eine spezielle Funknachricht, mit der ein batteriegespeistes Gerät bekanntmacht, daß es im Aufwachstatus ist und Z-Wave-Nachrichten empfangen kann.
  • Node Information Frame... ist eine spezielle Funknachricht, mit der ein Z-Wave-Gerät seine Geräteeigenschaften bekanntgibt.