Quickstart

This is a Notification Sensor for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1. Bring the Mini Sensor within direct range of your controller2. Carefully turn and lift the cover of your Mini Sensor to access the battery3. Remove the plastic pull-tab from the battery slot. The LED indicator will blink slowly4. Put your Z-Wave controller into inclusion mode5. Press and release the Z-Wave button on the Contact Sensor 3 TIMES quickly. The LED indicator will flash quickly6. A new motion and light sensor will appear on your controller's device listTroubleshooting TipsIf you are unable to include the Z-Wave Mini Sensor to your controller, please try one of the following:- Bring the Mini Sensor closer to your Z-Wave controller- Once in inclusion mode, press and release the Z-Wave button quickly 6-7 TIMES to ensure the command has gone through - Put your controller into EXCLUSION mode. Press and release the Z-Wave button quickly 3 TIMES, and then try adding it to your network again



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

PRODUCT FEATURES:- Accurate motion and light level detection - Wireless notifications and low battery alerts (when included to a Z-Wave gateway controller)- Custom automation scenarios based on both light and motion triggers (advanced configuration required)- Adjustable sensitivity levels for motion detection to fit your needs- Ultra small and simple design- Z-Wave Plus with improved 500 chip for faster and safer wireless communication- Flexible and quick installation SPECIFICATIONS:Model Number: ZSE09Z-Wave Signal Frequency: 908.42 MHzPower: 1 CR123A battery (included)Power Consumption: 0.15WOperating Temperature: 32104 FMotion detection: Up to 20 feetRange: Up to 100 feet line of sightInstallation and Use: Indoor onlyDimensions: 1.9 x 1.8 Weight:oz

Reset to factory default When your networks primary controller is missing or otherwise inoperable, you may need to reset the device to factory settings manually. To complete the process, make sure the Mini Sensor is powered on, then open the cover and PRESS AND HOLD the Z-Wave button for AT LEAST 10 SECONDS until the LED indicator flashes ONCE. Release the button. NOTE: All previously recorded activity and custom settings will be erased from the devices memory.
Inclusion 1. Bring the Mini Sensor within direct range of your controller2. Carefully turn and lift the cover of your Mini Sensor to access the battery3. Remove the plastic pull-tab from the battery slot. The LED indicator will blink slowly4. Put your Z-Wave controller into inclusion mode5. Press and release the Z-Wave button on the Contact Sensor 3 TIMES quickly. The LED indicator will flash quickly6. A new motion and light sensor will appear on your controller's device listTroubleshooting TipsIf you are unable to include the Z-Wave Mini Sensor to your controller, please try one of the following:- Bring the Mini Sensor closer to your Z-Wave controller- Once in inclusion mode, press and release the Z-Wave button quickly 6-7 TIMES to ensure the command has gone through - Put your controller into EXCLUSION mode. Press and release the Z-Wave button quickly 3 TIMES, and then try adding it to your network again
Exclusion 1. Make sure the Mini Sensor is powered on and located within direct range of your Z-Wave gateway controller2. Put your Z-Wave controller into exclusion mode3. Press and release the Z-Wave button 3 TIMES quickly. The LED indicator will flash quickly 4. The Mini Sensor should disappear from your controller's device list
NIF XXXNIF
Wakeup If you change settings and parameters for the sensor, you may need to wake it up manually for the changes to be recorded. Press and release the Z-Wave button ONCE to wake the device up. The LED indicator will flash ONCE.The sensors wake-up interval is set to 12 hours by default to save battery life. Though not recommended, you can change the wake-up interval using your controllers advanced settings if available. Minimum value: 300s (5 minutes), maximum value: 16,777,200s (around 194 days). Accepted values need to match minute intervals, so 300, 360, 420, etc.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Group 1 for lifeline communication of motion / no motion and light level status to Z-Wave controller. Supported command classes:NOTIFICATION_REPORT_V4SENSOR_BINARY_REPORT_V2SENSOR_MULTILEVEL_REPORT_V7BATTERY_REPORTDEVICE_RESET_LOCALLY_NOTIFICATION
2 5 Group 2 for control command communication to associated Z-Wave devices in the network. Use parameters 2, 3, 5, and 8 to configure this groups settings. Supported command classes:BASIC_SET
3 5 Group 3 for notifications to Z-Wave devices associated in this group. Supported command classes:NOTIFICATION_REPORT_V4
4 5 Group 4 for notifications to Z-Wave devices associated in this group. Supported command classes:SENSOR_BINARY_REPORT_V2

Configuration Parameters

Parameter 1: Motion Sensitivity

Choose the right motion sensitivity for your environment and lifestyle. Adjust detection just right by choosing a value from 8 to 255, where 8 stands for high sensitivity level (detection of the smallest movement) and 255 stands for very low sensitivity level.
Size: 1 Byte, Default Value: 12

Setting Description
8 - 255 Motion detection sensitivity

Parameter 10: LED Notifications

Use this parameter to turn LED notifications on or off for motion detection.
Size: 1 Byte, Default Value: 1

Setting Description
0 LED disabled
1 LED enabled

Parameter 2: Trigger ON Duration

Set the duration you want the associated device to stay ON for after being triggered by the sensor before it automatically turns OFF. The number entered as the value corresponds to the number of seconds. So if 30 is entered by default, the associated device will stay ON for 30 seconds after the Mini Sensor reports status change (BASIC_SET command) and triggers the device, it will then turn off automatically. Its an easy and quick way to set up a motion-based lighting event. If you change this setting to 300, the associated Z-Wave light fixture will stay ON for 5 minutes after motion has been detected by the Mini Sensor. The value set for this parameter needs to be greater than value set in parameter 6.
Size: 2 Byte, Default Value: 30

Setting Description
5 - 600 Number of seconds the associated device to stay ON for after being triggered by the sensor before it automatically turns OFF

Parameter 3: Trigger Action

You can choose if your Mini Sensor turns an associated device on or off when sending the BASIC SET command. Use value 0 to turn the associated device OFF and value 255 to turn it ON. Adjust brightness level for a Z-Wave dimmer (Multilevel switch) by putting in any value between 1 and 99.
Size: 1 Byte, Default Value: 255

Setting Description
255 Associated device will turn ON when triggered by the sensor
1 - 99 Brightness level (percentage) the associated device will turn ON to when triggered by the sensor

Parameter 4: Motion Detection

Use this parameter to enable and disable motion detection on your Mini Sensor.
Size: 1 Byte, Default Value: 255

Setting Description
255 Motion detection enabled

Parameter 5: Light Trigger Level

Set your light sensor as a secondary trigger for associated devices. If light level in a room falls beyond the set point and motion is detected, the Mini Sensor will send BASIC_SET command to associated devices to turn ON. The number entered as the value corresponds to the number of LUX. So if 100 is entered by default, the associated device will turn ON if light level last reported by the sensor is under 100 LUX and if motion has been detected by your Mini Sensor. Values: 01000 (LUX). 100 (LUX)default setting.
Size: 2 Byte, Default Value: 100

Setting Description
0 - 1000 Light level change (in LUX) to set off light trigger

Parameter 6: Motion Trigger Interval

Adjust the time when motion is reported again after initial trigger. The number entered as the value corresponds to the number of seconds. So if 8 is entered by default, the Mini Sensor will report motion for 8 seconds after it first detects movement. The value set for this parameter can NOT be greater than value set in parameter 2.NOTE: Small interval will increase activity and decrease battery life.
Size: 1 Byte, Default Value: 8

Setting Description
1 - 8 Number of seconds for motion trigger interval

Parameter 7: Light Polling Interval

Decide how often you want the Mini Sensor to report light level to the controller and associated devices. The number entered as the value corresponds to the number of seconds. So if 180 is entered by default, the Mini Sensor will report light level values every 3 minutes. The value set for this parameter can NOT be greater than the wake-up interval.NOTE: Small interval will increase activity and decrease battery life.
Size: 2 Byte, Default Value: 180

Setting Description
60 - 360000 Light polling interval in seconds

Parameter 8: Light Trigger

Use this parameter to enable and disable the light sensor as secondary trigger. If this feature is enabled, the Mini Sensor will activate associated devices based on motion AND light level set in parameter 5.
Size: 1 Byte, Default Value: 0

Setting Description
0 Light trigger disabled
255 Light trigger enabled

Parameter 9: Light Report

Choose light level change to be reported by the Mini Sensor to the controller. The number entered as the value corresponds to the number of LUX. So if 100 is entered by default, the sensor will report any change of 100 LUX or more.
Size: 2 Byte, Default Value: 100

Setting Description
0 - 255 Light level change (in LUX) to be reported by the sensor to the controller

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 66 FW: 3.80
Z-Wave Version 6.51.06
Certification ID ZC10-16085198
Z-Wave Product Id 0x027A.0x0003.0x0083
Sensors
Color
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoNotification Sensor