Quickstart

This is a Thermostat - HVAC for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
From the CT100s Menu screen, touch MATE under the radio icon. The Network Include screen displays a large r1.Touch MATE again. This initiates the network inclusion process. The MATE icon and the status indicator LEDs will blink.When the CT100 has successfully included into a Z-Wave network, theMATE icon is replaced by the LINK icon under the radio tower.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The CT100 Plus is a sleek, modern thermostat design for home automation systems.Its clean user interface compliments app-enabled systems.It features adjustable real-time alerts to enable cloud triggers, a robust data stream of HVAC information for cloud monitoring, and configurable comfort response settings to customize home control scenes.The CT100 Plus is compatible with all popular HVAC systems and is battery-operated without the need for a C-wire.

Reset to factory default Switch the thermostat to Off Mode.Press and hold the lower left corner of touch screen for five (5) seconds. The thermostat then resets itself, displays its current firmware version, and restarts in Off Mode.Use this procedure only in the event that the network primary controller is missing or otherwise inoperable.
Inclusion From the CT100s Menu screen, touch MATE under the radio icon. The Network Include screen displays a large r1.Touch MATE again. This initiates the network inclusion process. The MATE icon and the status indicator LEDs will blink.When the CT100 has successfully included into a Z-Wave network, theMATE icon is replaced by the LINK icon under the radio tower.
Exclusion Same process as inclusion. Similarly, when you are trying to exclude from a network, the LINK icon disappears when the node has successfully excluded the network.
NIF XXXNIF
Wakeup When included into a Z-Wave network on battery power, this device is a FLiRS device.The Thermostat will wake up for communication when it receives a valid Z-Wave beam.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 2 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 1: Temperature Reporting Threshold

The Temperature Reporting Threshold Con!guration Set Command sets the reporting threshold for Reporting Threshold changes in the ambient temperature as detected by the thermostat.
Size: 1 Byte, Default Value: 2

Setting Description

Parameter 10: Temperature Reporting Filter

The Temperature Reporting Filter configuration command sets upper and lower bounds of the ambient temperature reporting.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 31868 Byte 1: 0 -124 (lower bound), Byte 2: 0-124 (upper bound)

Parameter 12: Multicast

This parameter controls how the thermostat sends unsolicited reports.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 0 = Disabled, 1 = Enabled

Parameter 14: Save Energy Mode Type

This configuration value is used to read/white what behavior Save Energy Mode causes in the thermostat when the thermostat enters Save Energy Mode.
Size: 1 Byte, Default Value: 3

Setting Description
1 - 255 1=Adjust by target delta, 2=Least consuming point in the running program, 3=Save energy absolute setpoint, 255=Save Energy not supported (read-only value)

Parameter 2: HVAC Settings

The HVAC Settings Configuration Report Command returns the current HVAC con!guration. The HVAC settings must be !xed before the thermostat is joined to the Z-Wave network.
Size: 4 Byte, Default Value: 0

Setting Description
0 - 2147483647 Byte 1: normal (1) or heat pump (2). Byte 2, Bits 7-4: Gas (1) or Electric (2). Byte 2, Bits 3-0: # of Auxiliary Stages. Byte 3: # of Heat Pump Stages. Byte 4: # of Cool Stages.

Parameter 3: Utility Lock

The Utility Lock Con!guration Set command enables or disables the utility lock. If the utility lock is enabled, the setpoint cannot be modi!ed directly via the thermostat screen.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 255 0 = Disabled, 1 - 255 = Enabled

Parameter 4: C-Wire/Battery

The C-Wire / Battery Status Con!guration Report Command returns the status of the thermostat power source. The power state is fixed when the thermostat joins the network.
Size: 1 Byte, Default Value: 0

Setting Description
1 - 2 1=C-Wire, 2=Battery

Parameter 5: Humidity Reporting Threshold

The Humidity Threshold Con!guration Set Command sets the reporting threshold for changes in the relative humidity as detected by the thermostat.
Size: 1 Byte, Default Value: 5

Setting Description
0 - 3 0 = Disabled, 1 = 3% RH, 2 = 5% RH, 3 = 10% RH

Parameter 6: Auxiliary/Emergency Mode

The Auxiliary/Emergency con!guration command enables or disables auxiliary / emergency heating in the thermostat.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 0 = Disabled, 1 = Enabled

Parameter 7: Thermostat Swing Temperature

The Thermostat Swing Temperature configuration command sets swing temperature on the Temperature thermostat.
Size: 1 Byte, Default Value: 2

Setting Description
1 - 8 1 = 0.5, 2 = 1.0, 3 = 1.5, 4 = 2.0, 5 = 2.5, 6 = 3.0, 7 = 3.5, 8 = 4.0

Parameter 8: Thermostat Differential Temperature

The Thermostat Differential Temperature configuration command sets the differential temperature for multi-stage HVAC systems.
Size: 2 Byte, Default Value: 4

Setting Description
2 - 6 The thermostat differential temperature is in units of 0.5 degrees Fahrenheit.
0 - 1 0x00 (Heat) or Cool (0x01)

Parameter 9: Thermostat Recovery Mode

The Thermostat Recovery Mode configuration command sets the HVAC recovery mode type. The recovery mode determines when additional HVAC stages are turned of as the ambient temperature returns to the target temperature.
Size: 1 Byte, Default Value: 2

Setting Description
1 - 2 1 = Fast, 2 = Economy

Technical Data

Hardware Platform ZM5202
Device Type Thermostat - HVAC
Network Operation Listening Sleeping Slave
Firmware Version HW: 4 FW: 10.07:00.01
Z-Wave Version 6.51.07
Certification ID ZC10-16085182
Z-Wave Product Id 0x0098.0x6402.0x0001
Sensors Air TemperatureHumidity
Firmware Updatable Updatable by Manufacturer
Color White
Thermostat Power Source BatteryExternal TransformerMains powered (120V/240V)
Thermostat Modes AutoAuto ChangeoverAuxiliary/Emergency HeatCoolEnergy Save CoolEnergy Save HeatFan OnlyFurnaceHeat
Thermostat HVAC Systems Supported Universal
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoThermostat - HVAC