This is a
1. Put your Z-Wave controller into inclusion mode.2. Plug the SmatPlug into the power outlet.3. Press and hold on/off button about 5 seconds.4. Orange LED will be flashing about 2 seconds, then inclusion process will be start.5. Wait until inclusion will be done.
Smart- Plug plugs in between any appliance and the AC outlet.It measures its power consumption & sends that informationto your smartphone . It can also control power sourceconnected with appliance manually and remotely usingsmartphone.
Reset to factory default | Please use this procedure only when the network primary controller is missing or otherwise inoperable.1. Plug the SmatPlug into the power outlet.2. Press and hold on/off button about 10 seconds.3. Orange LED will be flashing about 2 seconds, then factory reset process will be start. |
Inclusion | 1. Put your Z-Wave controller into inclusion mode.2. Plug the SmatPlug into the power outlet.3. Press and hold on/off button about 5 seconds.4. Orange LED will be flashing about 2 seconds, then inclusion process will be start.5. Wait until inclusion will be done. |
Exclusion | 1. Put your Z-Wave controller into exclusion mode2. Plug the SmatPlug into the power outlet.3. Press and hold on/off button about 5 seconds.4. Orange LED will be flashing about 2 seconds, then exclusion process will be start.5. Wait until exclusion will be done. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus LifelineThe following Z-Wave signals may be sent to the nodes in this group: NOTIFICATION_REPORT, METER_REPORT, and CONFIGURATION_REPORT |
First 3 Bytes : Standby Power Setting ValueLast 1 Byte : Standby Power Enable/DisableIf the value is set by 1000, standby power equals 10.00w (0x0003E8) andstandby power enable is 1.total 0x0003E801 Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | standby power disable |
257 - 524033 | standby power enable with 0.01 to 20.47 W Standby |
Periodic Measurement Value Transmission Enable/Disable Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Periodic Measurement Value Transmission Disable |
1 | Periodic Measurement Value Transmission Enable |
Power Accumulation Start/Stop Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Power Accumulation Stop |
1 | Power Accumulation Start |
Connected Device Use / Not Use Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Connected Device Not Use |
1 | Connected Device Use |
Periodic Measurement Value Transmission IntervalMinimum time interval : 10minutesValue : 1 (10minutes * 1) = 10minutes intervalValue : 2 (10minutes * 2) = 20minutes interval..Value : 127(10min * 127) = 1270 minutes interval =>MAX Size: 1 Byte, Default Value: 6
Setting | Description |
---|---|
1 - 127 | 10min to 1270 min |
Hardware Platform | ZM5101 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 39.34 |
Z-Wave Version | 6.51.08 |
Certification ID | ZC10-16085176 |
Z-Wave Product Id | 0x0247.0x0042.0x0001 |
Firmware Updatable | Updatable by Professional/Technician |
Switch Type | Push Button |
Supported Meter Type | Electric Energy |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |