Quickstart

This is a Wall Controller for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Included as non-secure device:1. Insert the LIR2450 battery.2. Set the Z-Wave network main controller into learning mode( see Z-Waave network controller operating manul).3. Triple click the Z-button.4. If the inclusion is successful, the LED will blink in blue less than for 5 seconds and then keep on for 15 seconds.Included as a secure device:1. Insert the LIR2450 battery.2. Set the Z-Wave network main controller into learning mode( see Z-Wave network controller operating manual).3. Pressing and holding the Z-button for 3 seconds.4. If the inclusion is successful, the LED will blink in green less than for 5 seconds and then keep on for 15 seconds.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The Scene Controller is a wireless, portable and rechargeable scene switch. It can control a Z-Wave device, such as smart plug, smart dimmer with a Z-Wave gateway. You can also activate a scene like sleep scene, movie scene and entertainment scene with it.

Reset to factory default Pressing and holding the Z-button for 20 seconds. Release the button after 20 seconds, LED will keep in yellow for 3 seconds. Scene Controller will be reset to factory defaults if you short press the button within this 3 seconds.Using this procedure only in the event that the network primary controller is missing or otherwise inoperable.
Inclusion Included as non-secure device:1. Insert the LIR2450 battery.2. Set the Z-Wave network main controller into learning mode( see Z-Waave network controller operating manul).3. Triple click the Z-button.4. If the inclusion is successful, the LED will blink in blue less than for 5 seconds and then keep on for 15 seconds.Included as a secure device:1. Insert the LIR2450 battery.2. Set the Z-Wave network main controller into learning mode( see Z-Wave network controller operating manual).3. Pressing and holding the Z-button for 3 seconds.4. If the inclusion is successful, the LED will blink in green less than for 5 seconds and then keep on for 15 seconds.
Exclusion To remove the Scene Controller from the Z-Wave network:(1) Insert the LIR2450 battery.(2) Set the Z-Wave network main controller into remove mode(see Z-Wave controller operating manual).(3) Triple click the Z-button, if the exclusion is successful, LEDwill blink in orange for less than 5 seconds and then keep onfor 3 seconds.
NIF XXXNIF
Wakeup Pressing and holding Z-Button for 3 seconds. Led will turn to green,which means Scene Controller has been woken up.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Scene Controller will send Scene Controller sends the central scene notification command and battery report command to the associated nodes.
2 5 Scene Controller will send Basic Set command to the associated nodes.
3 5 Scene Controller will sendswitch multilevel set, the multilevel start level change and multilevel stop level change command to the associated nodes.

Configuration Parameters

Parameter 254: Enable/disable the configuration command

Lock/unlock all configuration parameters.
Size: 1 Byte, Default Value: 0

Setting Description
0 Unlock all configuration parameters.
1 Lock all configuration parameters

Parameter 255: Reset Scene Controller

Reset Scene Controller and remove from the Z-Wave network
Size: 4 Byte, Default Value: 0

Setting Description
1431655765 Reset Scene Controller and remove from the Z-Wave network

Technical Data

Hardware Platform ZM5101
Device Type Wall Controller
Network Operation Portable Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 6.51.08
Certification ID ZC10-16085174
Z-Wave Product Id 0x0208.0x0201.0x0009
Z-Wave Scene Type
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoWall Controller