Quickstart
This is a
Notification Sensor for XXXQFrequencyName.
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
Adding SensorA)Be sure that the Z-Wave Plus Controller you are using is compatible with the FireFighter. B)Either mount or move the sensor as close as possible to the place in the building where the sensor is to be mounted in order that the new Z-Wave Plus node is added to the correct place in the mesh network routing tables. C)To add the sensor to an existing Z-Wave Plus network, follow the directions to put your Z-Wave Plus Controller into add (inclusion) mode. The FireFighter enters add and remove (inclusion/exclusion) mode on pressing the learn button for 1 second which is located on the PCB between the LED and the tamper switch. If the LED starts blinking continuously, the sensor has no node ID and was not successfully added, so start step C over again. D)If after 5 seconds the LED is not blinking, look on the Z-Wave Plus controllers interface for feedback on whether the sensor was added successfully. If you do not see any feedback that the sensor was added, follow directions for removing the sensor from a Z-Wave Plus network, and then try adding the sensor again. If you are still having problems, you may need to add additional Z-Wave Plus listening devices in-between the controller and the sensor.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from
Z-Wave Alliance Product
data and may be incomplete. Please refer to the
Manufacturers Manual for more information.
Product Description
The Ecolink Z-Wave Plus FireFighter is an audio detector that listens for your smoke, fire, or Carbon Monoxide alarm and transmits as alert back to your hub to notify you of an event.It is easy to include/exclude with your hub, detector both temporal 3 and 4 patterns of your sensing device, has a 5 year battery life on (1) CR123A Lithium battery included.Dimensions are 3 1/8" x 1" tall.Certified to work with most Z-Wave enabled hubs on the market.
Reset to factory default |
Factory Default The FireFighter can be restored back to factory default settings which will remove its Z-Wave Plus node ID from the sensor (but not the controller) with the following steps. A)Put the battery into the sensor.B)Do not press the tamper switch.C)Hold the learn button down for 10 seconds until the LED turns RED.D)Release the learn button and wait for the sensors green LED to breath on and off continuously. The sensor is now ready to be added to a Z-Wave Plus network, and all settings have been restored.Please use this procedure only when the network primarycontroller is missing or otherwise inoperable. |
Inclusion |
Adding SensorA)Be sure that the Z-Wave Plus Controller you are using is compatible with the FireFighter. B)Either mount or move the sensor as close as possible to the place in the building where the sensor is to be mounted in order that the new Z-Wave Plus node is added to the correct place in the mesh network routing tables. C)To add the sensor to an existing Z-Wave Plus network, follow the directions to put your Z-Wave Plus Controller into add (inclusion) mode. The FireFighter enters add and remove (inclusion/exclusion) mode on pressing the learn button for 1 second which is located on the PCB between the LED and the tamper switch. If the LED starts blinking continuously, the sensor has no node ID and was not successfully added, so start step C over again. D)If after 5 seconds the LED is not blinking, look on the Z-Wave Plus controllers interface for feedback on whether the sensor was added successfully. If you do not see any feedback that the sensor was added, follow directions for removing the sensor from a Z-Wave Plus network, and then try adding the sensor again. If you are still having problems, you may need to add additional Z-Wave Plus listening devices in-between the controller and the sensor. |
Exclusion |
Removing SensorA)Any sensor can be removed from any Z-Wave Plus network with any Z-Wave Plus controller.Follow the directions to put your Z-Wave Plus Controller into Z-Wave Plus exclusion mode.B)Press the learn button located near the LED and Tamper switch.If successfully removed from the Z-Wave Plus network, the sensors LED should blink continuously if successful. |
NIF |
XXXNIF |
Wakeup |
XXXWakeupDescription |
Protection |
XXXProtection |
FirmwareUpdate |
XXXFirmwareUpdate |
SetAssociation |
XXXSetAssociation |
Association Groups:
Group Number |
Maximum Nodes |
Description |
1 |
5 |
Z-Wave Plus Lifeline |
Technical Data
Hardware Platform |
ZM5202 |
Device Type |
Notification Sensor |
Network Operation |
Reporting Sleeping Slave |
Firmware Version |
HW: 255 FW: 0.01 |
Z-Wave Version |
6.51.06 |
Certification ID |
ZC10-16075150 |
Z-Wave Product Id |
0x014A.0x0005.0x000F |
Color |
White |
Sensors |
Carbon MonoxideSmoke Density |
Communications Protocol |
Z-Wave Serial API |
Frequency |
XXfrequency |
Maximum transmission power |
XXantenna |