This is a
1) Connect the power supply.2) Set the Z-Wave network main controller into inclusion mode (see Z-Wave network controller operating manual).3) Triple click the Z-button or power up the device , RGB LED indicator should blink fast in blue.4) Smart Plug should be recognized and included into the Z-Wave network.
Smart plug is a Z-Wave Switch plugin module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report wattage consumption or kWh energy usage. Smart Plug is also a security Z-Wave device and supports the Over The Air (OTA) feature for the products firmware upgrade .
Reset to factory default | 1) Insert the Plug into a socket,2) Press and hold the Z button for more than 20 seconds,3) If holding time more than 20seconds, the RGB LED indicator will keep yellow for 2 seconds, which means resetting is complete.Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. |
Inclusion | 1) Connect the power supply.2) Set the Z-Wave network main controller into inclusion mode (see Z-Wave network controller operating manual).3) Triple click the Z-button or power up the device , RGB LED indicator should blink fast in blue.4) Smart Plug should be recognized and included into the Z-Wave network. |
Exclusion | 1) Insert the Plug into a socket.2) Set the Z-Wave network controller into the exclusion mode (see Z-Wave controller operating manual).3) Triple click the Z button.4) RGB LED indicator will blink orange till the removing process is completed, than the indicator will keep orange for 3 seconds. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline.Association command class allows Smart Plug to communicate with other Z-Wave devices directly, such as sending BASIC REPORT whenever the smart plug is turn on or off. |
Power threshold to be interpreted, when the change value of load power exceeds the setting threshold, the smart plug will send meter report to associated device (Group Lifeline). Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 | The function is disabled. |
1 - 65535 | The minimum change value in wattage for sending a meter report to the associated device |
Power percentage threshold to be interpreted, when change value of the load power exceeds the setting threshold, the smart plug will send meter report to associated device (Group Lifeline). Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | The function is disabled. |
1 - 255 | The minimum change value in wattage percent for sending a meter report to the associated device |
The interval of sending meter report(in term of wattage) to associated device (Group Lifeline). Size: 4 Byte, Default Value: 30
Setting | Description |
---|---|
0 | The function is disabled |
5 - 2678400 | The time for sending a meter report |
The interval of sending meter report(in term of kWh) to associated device (Group Lifeline). Size: 4 Byte, Default Value: 300
Setting | Description |
---|---|
0 | The function is disabled. |
5 - 2678400 | The time for sending a meter report |
The interval of sending meter report(in term of voltage) to associated device (Group Lifeline). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The function is disabled |
5 - 2678400 | The time for sending a meter report |
The interval of sending meter report(in term of current) to associated device (Group Lifeline). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The function is disabled. |
5 - 2678400 | The time for sending a meter report |
Smart Plug keep detecting the load power, once the AC current exceeds 16.5A for more than 5s, smart plug's relay will turn off. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | The function is disabled |
1 | The function is enabled. |
Define how the Plug reacts after the power supply is back on. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Smart Plug memorizes its state after a power failure |
1 | Connected device will be on after the power supply is reconnected |
2 | Connected device will be off after the power supply is reconnected |
Smart Plug can send notifications to association device (Group Lifeline) when state of smart plugs load change. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | The function is disabled |
1 | Send Basic report |
2 | Send Basic report only when Load condition is not changed by Z-WAVE Command |
After smart plug being included into a Z-Wave network, the RGB LED indicator will indicator the situation of load. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The Smart Plug will work in Power indication mode |
1 | The Smart Plug will work in Power indication mode for 5 seconds, when the state of Smart Plugs load changed. RGB LED indicator will turn off if there is no more switch action in 5 seconds. |
Hardware Platform | ZM5101 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 6.51.08 |
Certification ID | ZC10-16065127 |
Z-Wave Product Id | 0x0208.0x0101.0x000A |
Supported Meter Type | Electric Energy |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |