Quickstart

This is a On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1) Connect the power supply.2) Set the Z-Wave network main controller into inclusion mode (see Z-Wave network controller operating manual).3) Triple click the Z-button or power up the device , RGB LED indicator should blink fast in blue.4) Smart Plug should be recognized and included into the Z-Wave network.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Smart plug is a Z-Wave Switch plugin module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report wattage consumption or kWh energy usage. Smart Plug is also a security Z-Wave device and supports the Over The Air (OTA) feature for the products firmware upgrade .

Reset to factory default 1) Insert the Plug into a socket,2) Press and hold the Z button for more than 20 seconds,3) If holding time more than 20seconds, the RGB LED indicator will keep yellow for 2 seconds, which means resetting is complete.Use this procedure only in the event that the network primary controller is missing or otherwise inoperable.
Inclusion 1) Connect the power supply.2) Set the Z-Wave network main controller into inclusion mode (see Z-Wave network controller operating manual).3) Triple click the Z-button or power up the device , RGB LED indicator should blink fast in blue.4) Smart Plug should be recognized and included into the Z-Wave network.
Exclusion 1) Insert the Plug into a socket.2) Set the Z-Wave network controller into the exclusion mode (see Z-Wave controller operating manual).3) Triple click the Z button.4) RGB LED indicator will blink orange till the removing process is completed, than the indicator will keep orange for 3 seconds.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline.Association command class allows Smart Plug to communicate with other Z-Wave devices directly, such as sending BASIC REPORT whenever the smart plug is turn on or off.

Configuration Parameters

Parameter 151: Threshold of change in wattage

Power threshold to be interpreted, when the change value of load power exceeds the setting threshold, the smart plug will send meter report to associated device (Group Lifeline).
Size: 2 Byte, Default Value: 50

Setting Description
0 The function is disabled.
1 - 65535 The minimum change value in wattage for sending a meter report to the associated device

Parameter 152: Threshold of change in wattage percentage

Power percentage threshold to be interpreted, when change value of the load power exceeds the setting threshold, the smart plug will send meter report to associated device (Group Lifeline).
Size: 1 Byte, Default Value: 10

Setting Description
0 The function is disabled.
1 - 255 The minimum change value in wattage percent for sending a meter report to the associated device

Parameter 171: Intervals of sending METER REPORT (for wattage)

The interval of sending meter report(in term of wattage) to associated device (Group Lifeline).
Size: 4 Byte, Default Value: 30

Setting Description
0 The function is disabled
5 - 2678400 The time for sending a meter report

Parameter 172: Intervals of sending METER REPORT (for kWh)

The interval of sending meter report(in term of kWh) to associated device (Group Lifeline).
Size: 4 Byte, Default Value: 300

Setting Description
0 The function is disabled.
5 - 2678400 The time for sending a meter report

Parameter 173: Intervals of sending METER REPORT (for voltage).

The interval of sending meter report(in term of voltage) to associated device (Group Lifeline).
Size: 4 Byte, Default Value: 0

Setting Description
0 The function is disabled
5 - 2678400 The time for sending a meter report

Parameter 174: Intervals of sending METER REPORT (for current).

The interval of sending meter report(in term of current) to associated device (Group Lifeline).
Size: 4 Byte, Default Value: 0

Setting Description
0 The function is disabled.
5 - 2678400 The time for sending a meter report

Parameter 20: Overcurrent protection

Smart Plug keep detecting the load power, once the AC current exceeds 16.5A for more than 5s, smart plug's relay will turn off.
Size: 1 Byte, Default Value: 1

Setting Description
0 The function is disabled
1 The function is enabled.

Parameter 21: Setting Smart Plugs load status after re-power on

Define how the Plug reacts after the power supply is back on.
Size: 1 Byte, Default Value: 0

Setting Description
0 Smart Plug memorizes its state after a power failure
1 Connected device will be on after the power supply is reconnected
2 Connected device will be off after the power supply is reconnected

Parameter 24: Notification when Load status change

Smart Plug can send notifications to association device (Group Lifeline) when state of smart plugs load change.
Size: 1 Byte, Default Value: 1

Setting Description
0 The function is disabled
1 Send Basic report
2 Send Basic report only when Load condition is not changed by Z-WAVE Command

Parameter 27: Indicator modes

After smart plug being included into a Z-Wave network, the RGB LED indicator will indicator the situation of load.
Size: 1 Byte, Default Value: 0

Setting Description
0 The Smart Plug will work in Power indication mode
1 The Smart Plug will work in Power indication mode for 5 seconds, when the state of Smart Plugs load changed. RGB LED indicator will turn off if there is no more switch action in 5 seconds.

Technical Data

Hardware Platform ZM5101
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 6.51.08
Certification ID ZC10-16065127
Z-Wave Product Id 0x0208.0x0101.0x000A
Supported Meter Type Electric Energy
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoOn/Off Power Switch