This is a
When the device is not added to a Z-Wave network, then triple short clicks of the inclusion button will start the inclusion.
Z-Wave to Systemair HVAC Adapter is an Z-Wave Interface adapter, which connects the Z-Wave network with the Systemair Heat Recovery Ventilation. The Systemair HVAC is a residential HRV system, which can be controlled locally by one or more UI, as well as remotely by a mobile App or a browser via Z-Wave network.
Reset to factory default | To do a Factory Reset the user must follow the following procedure: - Press and hold the inclusion button for 6 seconds, then - Release it, and then - Press it again and hold it for 3 secondsThe Z-Wave Adapter is indicating each phase with a different LED patternsee Operational modes and indicators in the User's Manual. |
Inclusion | When the device is not added to a Z-Wave network, then triple short clicks of the inclusion button will start the inclusion. |
Exclusion | When the device is already included in a Z-Wave network, then triple short clicks of the inclusion button will exclude it from that Z-Wave network. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
Read Only Parameter, shows what is the Type of the Systemair HVAC Unit. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 5 | See User Manual |
12 - 21 | See User Manual |
Read Only Parameter, shows how long the filter can be used in steps of 30 days. Example 6 = 180 days. Size: 2 Byte, Default Value: 12
Setting | Description |
---|---|
6 | x 30 = 180 days |
9 | x 30 = 270 days |
12 | x 30 = 360 days |
15 | x 30 = 450 days |
Read Only Parameter, shows how many days the filter has been used since the last change. The value can be used to calculate the Filter remaining time by the equation: Filter Remaining Days = (Parameter_2 x 30) - Parameter_3 Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 500 | The counter stops on 500 |
Read Only Parameter, shows how many seconds are left for Boost mode. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
240 - 0 | Counts down while Boost mode is active |
Read Only Parameter, shows the min change available in degrees Celsius x 10. Example 25 = 2.5 degree Celsius. Size: 2 Byte, Default Value: 10
Setting | Description |
---|---|
10 | /10 = 1.0 degrees Celsius step |
25 | /10 = 2.5 degrees Celsius setp |
Shows the Firmware Version available in the Z-Wave adapter for the Firmware Target 2. This parameter must be written after successful uploading of the firmware image for the local UI. Example UI Version 5.02.03:MSB - x, don't care,Next - 05,Next - 02,LSB - 03. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 16777215 | max version 255.255.255 |
Shows the Firmware Version available in the Z-Wave adapter for the Firmware Target 1. This parameter must be written after successful uploading of the firmware image for the Ventilation Unit. Example Ventilation Unit Version 6.07.08:MSB - x, don't care,Next - 06,Next - 07,LSB - 08. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 16777215 | max version 255.255.255 |
Hardware Platform | ZM5202 |
Device Type | Thermostat - HVAC |
Network Operation | Always On Slave |
Firmware Version | HW: 2 FW: 0.01:00.80:36.80:16.00 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-16065101 |
Z-Wave Product Id | 0x0276.0x0139.0x0001 |
Thermostat Modes | Auto ChangeoverAway |
Thermostat Power Source | Mains powered (120V/240V) |
Firmware Updatable | Updatable by Consumer by RF |
Thermostat HVAC Systems Supported | Humidity ControlVentilation Control |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |