Quickstart

This is a Notification Sensor for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
-Click [Add] icon in Z-Wave PC Controller Program-Press a Func_Button 3 time in HS1DS-Z (Door Sensor), Green LED is Blinking 3 times within 1 second.-If Inclusion Process is successful, Green led will turn off.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Smart Door Sensor can detect the open-close state of doors and windows, when people leave home.Once the smart door sensor detects the door is opened, it will send the information of door opened to users mobile phone immediately. User can know if their houses are intruded, no matter where they are.With 2 AA batteries, the battery life is more than 1 year.It is also very easy to install, user should only paste the smart door sensor on the door and door frame.

Reset to factory default Long press Func_Button while installing batteries in HS1DS-Z -Device Reset Locally notification is Transmitted-Please use the reset procedure only when the primary controller is missing or inoperable
Inclusion -Click [Add] icon in Z-Wave PC Controller Program-Press a Func_Button 3 time in HS1DS-Z (Door Sensor), Green LED is Blinking 3 times within 1 second.-If Inclusion Process is successful, Green led will turn off.
Exclusion Click [Remove] icon in Z-Wave PC Controller Program-Press a Func_Button 3 times quickly in HS1DS-Z-If Exclusion Process is successful, Green led is Blinking 6 times, then turn off in HS1DS-Z
NIF XXXNIF
Wakeup -Wake up Notification is transmitted every 24 hours by default.-Wake up Notification is transmitted after Notification Report is Transmitted
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Lifeline association groupInclude command classe: Battery report, Notification report, and Device Reset Locally notification, Binary report.
2 5 Root Device group(Binary Sensor)Binary Sensor Command Class:Compatible with 300 series1-Binary Sensor reports status of open or close door via Lifeline.2-When the sensor detects status change between close door and open door, the device will be triggered.
3 5 Root Device group(Binary Sensor)Binary Sensor Command Class:Compatible with 300 series1-Binary Sensor reports the removed status of door sensor.2-When the sensor detects status change of tamper, the device will be triggered.
4 5 Root Device group(Notification)1-Notification report open door or close status via Lifeline.2- When the sensor detects status change between close door and open door, the device will be triggered.
5 5 Root Device group(Notification)1-Binary Sensor reports the removed status of door sensor.2- When the sensor detects status change of tamper, the device will be triggered.

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 255 FW: 1.25
Z-Wave Version 6.51.06
Certification ID ZC10-16055091
Z-Wave Product Id 0x0260.0x0168.0x0168
Firmware Updatable Not Updatable
Color Gray
Sensors Open/Closed (Binary)
Outdoor Use ok
IP (Ingress Protection) Rated ok
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Notification Sensor