Quickstart

This is a Remote Control - Simple for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1. Put Primary Controller into Inclusion Mode2. Press and Hold Control Programming Button for >2seconds, release when Green LED flashes



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Enjoy the comfort, convenience and energy efficiency of beautiful custom motorized window treatments featuring Z-Wave protocol for easy integration.Lighting control has never been more simple. Window treatments can be automated using your favorite Z-Wave certified gateway or security system, or controlled by a remote control.Raise or lower the shades to control just the right amount of light, privacy and solar heat. Shades can be fully open, fully closed or anywhere in between, its up to you.In addition, some systems will also report back the state of the battery charge on battery operated versions.

Reset to factory default Press and hold the button on the control for approximately 15 seconds (the LED will stop flashing when complete."Please use this procedure only when the network primary controller is missing or otherwise inoperable."
Inclusion 1. Put Primary Controller into Inclusion Mode2. Press and Hold Control Programming Button for >2seconds, release when Green LED flashes
Exclusion 1. Put Primary Controller into Inclusion Mode2. Press and Hold Control Programming Button for >2seconds, release when Green LED flashes
NIF XXXNIF
Wakeup The Wakeup command class should be configured by a hub when the remote is joined to a Z-Wave network. A WAKE_UP_INTERVAL_SET command should configure the NodeID at a minimum. The Wakeup interval can be configured to any value from 6 minutes to 25 hours. Recommendation is to leave the interval at the default of 12 hours to maximize battery life. The remote will wake up every WakeUpInterval and send a WakeUp Notification command as well as a battery report to the NodeID assigned with the Interval Set command. The WakeUp Notification will be sent within a few minutes of power being applied to the remote and then once every Wake Up Interval. A Wakeup Interval Capabilities command will inform the hub of the default, minimum, maximum and step size of the Wake Up interval.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Association Group #1 is dedicated Lifeline to primary control, primarily used for battery status reports, central scene cc, local reset cc.
2 12 Association Group #2 is dedicatedfor slave shades. Primary control commands, SWITCH_MULTILEVEL_CC, BASIC_CC BINARY CC

Special Operations as Z-Wave Controller

As long as this device is not included into a Z-Wave network of a different controller it is able to manage its own Z-Wave network as primary controller. As a primary controller the device can include and exclude other devices in its own network, manage associations, and reorganize the network in case of problems. The following controller functions are supported:

Inclusion of other devices

Communication between two Z-Wave devices only works if both belong to the same wireless network. Joining a network is called inclusion and is initiated by a controller. The controller needs to be turned into the inclusion mode. Once in this inclusion mode the other device needs to confirm the inclusion - typically by pressing a button.

If current primary controller in your network is in special SIS mode this and any other secondary controller can also include and exclude devices.

To become primary a contoller have to be resetted and then include a device.

1. Press and release Twice on Control Programming button. (Tap 2x on prog button)2.Slave sends NIF

Exclusion of other devices

The primary controller can exclude devices from the Z-Wave network. During exclusion the relationship between the device and the network of this controller is terminated. No communication between the device and other devices still in the network can happen after a successful exclusion. The controller needs to be turned into the exclusion mode. Once in this exclusion mode the other device needs to confirm the exclusion - typically by pressing a button.

Attention: Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from it's previous network.

1. Press and release Three times on Control Programming button. (Tap 3x on prog button)2. Slave sends NIF

Technical Data

Hardware Platform ZM5101
Device Type Remote Control - Simple
Network Operation Portable Controller
Firmware Version HW: 255 FW: 187.65
Z-Wave Version 6.61.00
Certification ID ZC10-16055082
Z-Wave Product Id 0x026E.0x5643.0x5A31
Z-Wave Scene Type Central Scene
Color White
Firmware Updatable Not Updatable
Switch Type Push Button with Indicator
Window Covering Control Features Endpoint Aware
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoRemote Control - Simple