Quickstart

This is a Notification Sensor for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
To add the ZSE40 to the Z-Wave network (inclusion), place the Z-Wave primary controller into inclusion mode.Press the Program Switch of ZSE40 for sending the NIF. After sending NIF, Z-Wave will send the auto inclusion, otherwise, ZSE40 will go to sleep after 20 seconds.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Enjoy 4 smart sensors in 1 compact device. Monitor motion, temperature, humidity, and light level.This is a secure device using 128-bit signal encryption. It requires a security enabled gateway controller for full functionality.The Zooz 4-in-1 sensor is packed with advanced features:- 7 levels of motion sensitivity to choose from- 3 modes for motion / temp led indicator notifications- Built-in tamper protection- Low battery alerts- Z-Wave Plus with improved 500 series chip for faster and safer wireless communicationZ-Wave Frequency: 908.42 MHz (US)Power: 2 AAA batteriesWireless Range: Up to 100 feet line of sightOperating Temperature: 5 - 104FInstallation: Indoor Use Only1 Year Warranty

Reset to factory default Remove cover to trigged tamper switch, LED flash once & send out Alarm Report.Press Program Switch 10 times within 10 seconds, ZSE40 will send the Device Reset Locally Notification command and reset to the factory default. (Remark: This is to be used only in the case of primary controller being inoperable or otherwise unavailable.)
Inclusion To add the ZSE40 to the Z-Wave network (inclusion), place the Z-Wave primary controller into inclusion mode.Press the Program Switch of ZSE40 for sending the NIF. After sending NIF, Z-Wave will send the auto inclusion, otherwise, ZSE40 will go to sleep after 20 seconds.
Exclusion To remove theZSE40 from the Z-Wave network (exclusion), place the Z-Wave primary controller into exclusion mode and follow its instruction to delete the ZSE40 to the controller.Press the Program Switch of ZSE40 once to be excluded.
NIF XXXNIF
Wakeup Use Wake Up command to set up the awaking time (from 10 minutes to 1 week) and send the wake up notification to controller
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 LifelineCOMMAND_CLASS_BASIC_SETCOMMAND_CLASS_BATTERY_REPORTCOMMAND_CLASS_DEVICE_RESET_LOCALLY_NOTIFICATIONCOMMAND_CLASS_NOTIFICATION_REPORTCOMMAND_CLASS_SENSOR_MULTILEVEL_V7

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 1 FW: 5.01:10.01
Z-Wave Version 6.51.06
Certification ID ZC10-16055079
Z-Wave Product Id 0x027A.0x2021.0x2101
Sensors Air TemperatureHumidityLuminanceMotion/No Motion (Binary)
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoNotification Sensor