Quickstart
This is a
Notification Sensor for XXXQFrequencyName.
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
Add the Sensor to Z-Wave Network1.Remove the sensor cover. 2.Make sure the sensor is powered. 3.Set Z-Wave controller or Z-Wave gateway into inclusion mode (Refer to the controller or gateway operating manual) 4.Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off alternately five times.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from
Z-Wave Alliance Product
data and may be incomplete. Please refer to the
Manufacturers Manual for more information.
Product Description
In the front casing, there is button that is used to carry out include, exclude or reset factory default settings on PCB Board.When power is first supplied, the LED will flash on and off alternately at one second intervals within 5 seconds if the detector has been added a Z-Wave network. Please get familiar with the terms below before starting the operations.This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
Reset to factory default |
Restore the Sensor to Factory Default SettingsNote: to use the reset procedure only when the primary controller is missing or inoperableReset procedure will delete all information on the Z-Wave network and Z-Wave controller or Z-Wave Gateway, and restore the sensor to factory default settings.1.Remove the device cover. 2.Make sure the sensor is powered. 3.Press and hold the button for 10 seconds, led will blink once. 4.Release the button. |
Inclusion |
Add the Sensor to Z-Wave Network1.Remove the sensor cover. 2.Make sure the sensor is powered. 3.Set Z-Wave controller or Z-Wave gateway into inclusion mode (Refer to the controller or gateway operating manual) 4.Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off alternately five times. |
Exclusion |
Delete the Sensor from Z-Wave Network1.Remove the device cover. 2.Make sure the sensor is powered. 3.Set Z-Wave controller or Z-Wave gateway into exclusion mode (Refer to the controller or gateway operating manual) 4.Press the button three times within 1.5 second, the device will enter exclusion mode. |
NIF |
XXXNIF |
Wakeup |
Wakeup the Sensor ManualUser can press button once to wake-up this sensor to send wakeup notification to controller, the Led will be blink one time. |
Protection |
XXXProtection |
FirmwareUpdate |
XXXFirmwareUpdate |
SetAssociation |
XXXSetAssociation |
Association Groups:
Group Number |
Maximum Nodes |
Description |
1 |
4 |
GROUP 1 is lifeline service that assigned to Sensor (Water leakage detector) status. It enables the sensor to send reports and readings to Z-Wave Controller or Z-Wave Gateway whenever the sensor is triggered. This Group Support:NOTIFICATION_REPORT_V4, BATTERY_REPORT, SENSOR_BINARY_REPORT_V2, DEVICE_RESET_LOCALLY_NOTIFICATION |
2 |
4 |
GROUP 2 allows for sending control commands to associated devices such as relay module, lighting, etc. This association group is configured through the advanced parameters no. 1 and 2. This Group Support:BASIC_SET. |
3 |
4 |
GROUP 3 allows for Send Notification to associated devices in this group. This Group Support: NOTIFICATION_REPORT_V4 |
4 |
4 |
GROUP 4 allows for Send Notification to associated devices in this group. This Group Support: SENSOR_BINARY_REPORT_V2 |
Technical Data
Hardware Platform |
ZM5202 |
Device Type |
Notification Sensor |
Network Operation |
Reporting Sleeping Slave |
Firmware Version |
HW: 48 FW: 2.40 |
Z-Wave Version |
6.51.06 |
Certification ID |
ZC10-16055075 |
Z-Wave Product Id |
0x0258.0x0003.0x0085 |
Sensors |
Water Flow |
Frequency |
XXfrequency |
Maximum transmission power |
XXantenna |