Quickstart

This is a Notification Sensor for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
To include the device start the inclusion on your controller and then hit the little button on the wireless module for 1 second



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

This products consists of a standard high-quality photo electric Smoke detector with a pluggable Z-Wave wireless interface module.The Smoke detector will also work as a stand alone product and is certified by VDS as '10 year Smoke Detector' Thesmoke chamber of the detector has a stainless steel reel with antistatic plastic chamber.A button allows on-device test of smoke chamber, electronics and battery. The device also offers a built-in self test andan electronic smoke chamber test to avoid the use of test aerosol. A low battery warning will last for 30 days but fullfunction of the detector is guaranteed during this time.The Z-Wave module allows to report the smoke and low battery alarm wirelessly to a central controller. The detector canalso be used as a wireless siren for alarm system or other applications.

Reset to factory default To reset the device keep the button pushed for 10 seconds. After 5 seconds the led starts flashing and after another 5seconds there is a short beep signaling the successful reset back to factory defaults. Use this procedure only when the network primary controller is missing or otherwise inoperable.
Inclusion To include the device start the inclusion on your controller and then hit the little button on the wireless module for 1 second
Exclusion To exclude the device start the inclusion on your controller and then hitthe little button on the wireless module for 1 second
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 10 Z-Wave Plus Lifeline
2 10 Alarm Reports. All devices in this group will receive Alarm notifications (Smoke , Battery Low, Tamper)
3 10 Switching Command. All devices in this group will receive a BASIC SET command on Smoke Alarms. Configuration parameter 3 and 4 will define when ON and when OFF is sent.

Configuration Parameters

Parameter 1: Siren alarm sequence interval

The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the interval in seconds.
Size: 1 Byte, Default Value: 10

Setting Description
6 - 129 seconds

Parameter 2: Siren alarm tone length

The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the sound versus silence within this interval. Please make sure this value is always smaller (shorter time) than parameter 1 that defines the whole sequence.
Size: 1 Byte, Default Value: 8

Setting Description
1 - 99 seconds

Parameter 3: Value of On-Command

This value is sent as BASIC Set to Association Group 3 when an Smoke Alarm occurs.
Size: 1 Byte, Default Value: 99

Setting Description

Parameter 4: Value of Off-Command

This value is sent as BASIC Set to Association Group 3 when an Smoke Alarm is cleared.
Size: 1 Byte, Default Value: 0

Setting Description

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Listening Sleeping Slave
Firmware Version HW: 1 FW: 1.02
Z-Wave Version 6.51.06
Certification ID ZC10-16055070
Z-Wave Product Id 0x0115.0x0x04.0x0x04
Firmware Updatable Updatable by Consumer by RF
Outdoor Use ok
Sensors Smoke Density
Color White
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoNotification Sensor