This is a
To include the device start the inclusion on your controller and then hit the little button on the wireless module for 1 second
This products consists of a standard high-quality photo electric Smoke detector with a pluggable Z-Wave wireless interface module.The Smoke detector will also work as a stand alone product and is certified by VDS as '10 year Smoke Detector' Thesmoke chamber of the detector has a stainless steel reel with antistatic plastic chamber.A button allows on-device test of smoke chamber, electronics and battery. The device also offers a built-in self test andan electronic smoke chamber test to avoid the use of test aerosol. A low battery warning will last for 30 days but fullfunction of the detector is guaranteed during this time.The Z-Wave module allows to report the smoke and low battery alarm wirelessly to a central controller. The detector canalso be used as a wireless siren for alarm system or other applications.
Reset to factory default | To reset the device keep the button pushed for 10 seconds. After 5 seconds the led starts flashing and after another 5seconds there is a short beep signaling the successful reset back to factory defaults. Use this procedure only when the network primary controller is missing or otherwise inoperable. |
Inclusion | To include the device start the inclusion on your controller and then hit the little button on the wireless module for 1 second |
Exclusion | To exclude the device start the inclusion on your controller and then hitthe little button on the wireless module for 1 second |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 10 | Z-Wave Plus Lifeline |
2 | 10 | Alarm Reports. All devices in this group will receive Alarm notifications (Smoke , Battery Low, Tamper) |
3 | 10 | Switching Command. All devices in this group will receive a BASIC SET command on Smoke Alarms. Configuration parameter 3 and 4 will define when ON and when OFF is sent. |
The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the interval in seconds. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
6 - 129 | seconds |
The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the sound versus silence within this interval. Please make sure this value is always smaller (shorter time) than parameter 1 that defines the whole sequence. Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
1 - 99 | seconds |
This value is sent as BASIC Set to Association Group 3 when an Smoke Alarm occurs. Size: 1 Byte, Default Value: 99
Setting | Description |
---|
This value is sent as BASIC Set to Association Group 3 when an Smoke Alarm is cleared. Size: 1 Byte, Default Value: 0
Setting | Description |
---|
Hardware Platform | ZM5202 |
Device Type | Notification Sensor |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 1 FW: 1.02 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-16055070 |
Z-Wave Product Id | 0x0115.0x0x04.0x0x04 |
Firmware Updatable | Updatable by Consumer by RF |
Outdoor Use | ok |
Sensors | Smoke Density |
Color | White |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |