To include the device start the inclusion on your controller and then hit the little button on the wireless module for 1 second
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
This products consists of a standard high-quality photo electric Smoke detector with a pluggable Z-Wave wireless interface module.The Smoke detector will also work as a stand alone product and is certified by VDS as '10 year Smoke Detector' Thesmoke chamber of the detector has a stainless steel reel with antistatic plastic chamber.A button allows on-device test of smoke chamber, electronics and battery. The device also offers a built-in self test andan electronic smoke chamber test to avoid the use of test aerosol. A low battery warning will last for 30 days but fullfunction of the detector is guaranteed during this time.The Z-Wave module allows to report the smoke and low battery alarm wirelessly to a central controller. The detector canalso be used as a wireless siren for alarm system or other applications.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
To reset the device keep the button pushed for 10 seconds. After 5 seconds the led starts flashing and after another 5seconds there is a short beep signaling the successful reset back to factory defaults. Use this procedure only when the network primary controller is missing or otherwise inoperable.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 10 | Z-Wave Plus Lifeline |
2 | 10 | Alarm Reports. All devices in this group will receive Alarm notifications (Smoke , Battery Low, Tamper) |
3 | 10 | Switching Command. All devices in this group will receive a BASIC SET command on Smoke Alarms. Configuration parameter 3 and 4 will define when ON and when OFF is sent. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the interval in seconds. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
6 - 129 | seconds |
The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the sound versus silence within this interval. Please make sure this value is always smaller (shorter time) than parameter 1 that defines the whole sequence. Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
1 - 99 | seconds |
This value is sent as BASIC Set to Association Group 3 when an Smoke Alarm occurs. Size: 1 Byte, Default Value: 99
Setting | Description |
---|
This value is sent as BASIC Set to Association Group 3 when an Smoke Alarm is cleared. Size: 1 Byte, Default Value: 0
Setting | Description |
---|
Hardware Platform | ZM5202 |
Device Type | Notification Sensor |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 1 FW: 1.02 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-16055070 |
Z-Wave Product Id | 0x0115.0x0x04.0x0x04 |
Firmware Updatable | Updatable by Consumer by RF |
Outdoor Use | ok |
Sensors | Smoke Density |
Color | White |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |