This is a
When the controller is in add mode and the blue LED is blinking on theZW15RM, press and hold the program button of ZW15RM for 3 second, andthen the controller will verify the add.
The ZW15RM TR Duplex Receptacle is a perfect wireless manual and remote on/off control replacement of regular receptacles, controlling table and floor lamps, small appliances, etc. It provides two different type outlets. One outlet with Z-Wave mark has programmable functions such as scenes, association, schedule event, etc. It is fully interoperable with other Z-Wave certified device from other manufacturers and/or other applications. It can report wattage energy usage or kWh energy usage to a Z-Wave gateway.It has a Blue LED on the face cover indicates the status of the controlled outlet and/or act as a night light. The other outlet with Tamper-Resistant feature provides constant power, helps you and your families prevent electrical injuries.
Reset to factory default | Once program button is pressed and hold for 10 second, the device will send a device reset locally notification to controller. Then clear all of information forthe network, and restore factory defaults, and reset the module. Use thisprocedure only in the event that the network primary controller is missing or otherwise inoperable. |
Inclusion | When the controller is in add mode and the blue LED is blinking on theZW15RM, press and hold the program button of ZW15RM for 3 second, andthen the controller will verify the add. |
Exclusion | When the controller is in remove mode, press and hold the program button ofZW15RM for 3 second, and then the controller will remove it from the currentZ-Wave network, and the LED will blink on the receptacle,when power on. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline: Send device reset locally notification |
2 | 5 | StatusReport: Send basic report |
3 | 5 | PowerReport: Send meter power report |
synchronization of outlet power and LED indicator Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Power on, LED off |
1 | Power on, LED on |
Hardware Platform | ZM5202 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 5.10 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-16055066 |
Z-Wave Product Id | 0x011A.0x0111.0x0105 |
Supported Meter Type | Electric Energy |
Switch Type | Push Button with Indicator |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |