Quickstart
This is a
Notification Sensor for XXXQFrequencyName.
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
Add the Sensor (Door/Window detector) to Z-Wave Network1.Remove the sensor cover. 2.Make sure the sensor is powered. 3.Set Z-Wave controller or Z-Wave gateway into inclusion mode (Refer to the controller or gateway operating manual) 4.Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off alternately five times.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from
Z-Wave Alliance Product
data and may be incomplete. Please refer to the
Manufacturers Manual for more information.
Product Description
Door SensorTwo status: open and close Compatible with 300 series and 500 seriesPower: CR14250 x1Standby current: 1uA Battery life: 10 yearsInstall on the door or windowEasily install with screws or sticker.Operation temperature: 0-40Size: Main body (L x W x H): 70mmx20mmx20mmDeputy body (L x W x H): 40mmx11mmx11mm
Reset to factory default |
Restore the Sensor (Door/Window detector) to Factory Default SettingsReset procedure will delete all information on the Z-Wave network and Z-Wave controller or Z-Wave Gateway, and restore the sensor to factory default settings.1.Remove the device cover. 2.Make sure the sensor is powered. 3.Press and hold the button for 10 seconds, 4.Release the button. |
Inclusion |
Add the Sensor (Door/Window detector) to Z-Wave Network1.Remove the sensor cover. 2.Make sure the sensor is powered. 3.Set Z-Wave controller or Z-Wave gateway into inclusion mode (Refer to the controller or gateway operating manual) 4.Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off alternately five times. |
Exclusion |
Delete the Sensor (Door/Window detector) from Z-Wave Network1.Remove the device cover. 2.Make sure the sensor is powered. 3.Set Z-Wave controller or Z-Wave gateway into exclusion mode (Refer to the controller or gateway operating manual) 4.Press the button three times within 1.5 second, the device will enter exclusion mode. |
NIF |
XXXNIF |
Wakeup |
Manual Wakeup the SensorYou can press the button once to wake up the device and send wakeup notification to controller. If press successfully, the LED will blink one time. |
Protection |
XXXProtection |
FirmwareUpdate |
XXXFirmwareUpdate |
SetAssociation |
XXXSetAssociation |
Association Groups:
Group Number |
Maximum Nodes |
Description |
1 |
4 |
Every group can be support to associated 5 devices max.GROUP 1 is lifeline service that assigned to Sensor (Door/Window detector) statusOpen/Close. It enables the sensor to send reports and readings to Z-Wave Controller or Z-Wave Gateway whenever the sensor is triggered. This Group Support:NOTIFICATION_REPORT BATTERY_REPORT SENSOR_BINARY_REPORT DEVICE_RESET_LOCALLY_NOTIFICATIONGROUP 2 allows for sending control commands to associated devices such as relay module, lighting, etc. This association group is configured through the advanced parameters no. 1 and 2. This Group Support:BASIC_SET.GROUP 3 allows for Send Notification to associated devices in this group. This Group Support: NOTIFICATION_REPORTGROUP 4 allows for Send Notification to associated devices in this group. This Group Support: SENSOR_BINARY_REPORT |
Technical Data
Hardware Platform |
ZM5202 |
Device Type |
Notification Sensor |
Network Operation |
Reporting Sleeping Slave |
Firmware Version |
41 |
Z-Wave Version |
6.51.06 |
Certification ID |
ZC10-16020010 |
Z-Wave Product Id |
0x0258.0x0003.0x0082 |
Frequency |
XXfrequency |
Maximum transmission power |
XXantenna |