Quickstart

This is a Light Dimmer Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1. Plug the 2-pin AC power plugs of lighting device to the receptacle of HS-PD100+2. Insert the module's 3-pin plug into an AC outlet of your preferred location. In normal operating mode, the LED on the front panel will be lit. 3. Add(Include) the module into your network by a Z-Wave certified controller.Normally, the sequence is as follows:a. Place your network controller into inclusion mode by following the controller manufacturer's instructionsb. When the controller is ready, single click the button on the front of HS-PD100+c. The controller should indicate that the new device was added successfully.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

HS-PD100+ is a Z-Wave Plus certifed plug-in lamp module that features remote wireless on/off/dim control of most lighting loads. The unit is small in size and will work with all HomeSeer (and most other) home automation controllers.

Reset to factory default Use this procedure only in the event that the network primary controller is lost or otherwise inoperable.1. Unplug the HS-PD100+ from the AC outlet and also unplug the power plugs of the lighting from the module (if plugged in)2. Press and hold the button on the HS-PD100+3. Plug the HS-PD100+ back into the AC outlet with the button pressed4. After 3 seconds, release the button. If you see the button blink, that means that the HS-PD100+ has been reset successfully
Inclusion 1. Plug the 2-pin AC power plugs of lighting device to the receptacle of HS-PD100+2. Insert the module's 3-pin plug into an AC outlet of your preferred location. In normal operating mode, the LED on the front panel will be lit. 3. Add(Include) the module into your network by a Z-Wave certified controller.Normally, the sequence is as follows:a. Place your network controller into inclusion mode by following the controller manufacturer's instructionsb. When the controller is ready, single click the button on the front of HS-PD100+c. The controller should indicate that the new device was added successfully.
Exclusion a. Place your network controller into exclusion mode by following the controller manufacturer's instructionsb. When the controller is ready, single click the button on the front of HS-PD100+c. The controller should indicate that the device was excluded successfully.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline

Technical Data

Hardware Platform ZM5202
Device Type Light Dimmer Switch
Network Operation Always On Slave
Firmware Version FF
Z-Wave Version 6.51.02
Certification ID ZC10-16020008
Z-Wave Product Id 0x0184.0x4744.0x3032
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoLight Dimmer Switch