This is a
1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. 2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode.
This in-wall dual relay switch module is a transceiver which is a Z-Wave PlusTM enabled device and is fully compatible with any Z-WaveTM enabled network. Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration.This in-wall switch module is able to detect Instant power wattage and overload current (7.5A with resistive load) of connected light or appliances. When detecting overload state, the Module will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, disconnect and re-connect the Module will reset its overload condition to normal status. Adding to Z-WaveTM NetworkIn the front casing, there is an on/off button with LED indicator below which is used to toggle switch on and off or carry out inclusion, exclusion, reset or association. When first power is applied, its LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies that it has not been assigned a node ID and start auto inclusion.Auto InclusionThe function of auto inclusion will be executed as long as the in wall switch does not have Node ID and just connect the switch to main power.Note: Auto inclusion timeout is 2 minute during which the node information of explorer frame will be emitted once every several seconds. Unlike inclusion function as shown in the table below, the execution of auto inclusion is free from pressing the On/Off button on the Switch.
Reset to factory default | Use this procedure only in the event that the primary controller is lost or otherwise inoperable. 1. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode. 2. Within 1 second, press On/Off button again for 5 seconds. 3. IDs are excluded. |
Inclusion | 1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. 2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode. |
Exclusion | 1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. 2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter exclusion mode. 3. Node ID has been excluded. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus LifelineFor group 1, the Switch will report (1) ON/OFF status of Relay1 and Relay2 (2) Instant Power Consumption (Watt) of Relay1 and Relay2 (3) Accumulated Power Consumption (KWh) of Relay1 and Relay2 to Z-Wave Controller. |
2 | 1 | For group 2, the Switch will report (1) ON/OFF status of Relay1 (2) Instant Power Consumption (Watt) of Relay1 (3) Accumulated Power Consumption (KWh) of Relay1 to Z-Wave Controller. |
3 | 1 | For group 3, the Switch will report (1) ON/OFF status of Relay2 (2) Instant Power Consumption (Watt) of Relay2 (3) Accumulated Power Consumption (KWh) of Relay2 to Z-Wave Controller. |
If the setting is configured for 1hour (set value =720), the TZ04 will report its instant power consumption every 1 hour to the node of correspond Group. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). Size: 2 Byte, Default Value: 720
Setting | Description |
---|---|
1 - 32767 | 720*5s=3600s=1 hour |
Multi-Channel Command is a good way to control relay1 and relay2 of TZ04 individually. The endpoint3 of TZ04 is related to both relay1 and relay2. In some condition it becomes redundant in Multi-Channel Command Class. When the Existence of Endpoint3 is set as 2, the endpoint3 will be disabled. The default value is 1. Endpoint1 and Endpoint2 are fixed, only Endpoint3 is dynamic. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | 1 : Endpoint3 exist |
2 | 2 : No Endpoint3 |
If the setting is configured for 1hour (set value =6), the TZ04 will report its Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond Group. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). Size: 2 Byte, Default Value: 6
Setting | Description |
---|---|
1 - 32767 | 6*10min= 1 hour |
If Controller not using Multi_Channel command class to access the relay of TZ04, you may configure the select value to react the Basic Command ClassBinary Switch Command Class or Meter Command Class V3. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 | 1Relay1 |
2 | 2Relay2 |
3 | 3Relay1 & Relay2 |
Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle mode, default value is Edge mode. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | 1Edge mode |
2 | 2Pulse mode |
3 | 3Edge-Toggle mode |
This is a warning when the current of load over the preset threshold value, if the setting value is 750, when the load current of Relay1 or Relay2 over this value, TZ04 will send current meter report to the node of correspond Group, the Range of the setting value is from 10 to 750, and the default value is 750. Size: 2 Byte, Default Value: 750
Setting | Description |
---|---|
10 - 750 | 750*0.01A = 7.5A |
This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 or Relay2 over this value, TZ04 will send KWh Meter Report command to the node of correspond Group, minimum value is 1KWh and default value is 10000 kWh. Size: 2 Byte, Default Value: 10000
Setting | Description |
---|---|
1 - 10000 | 10000*1KWh = 10000KWh |
Whenever the AC power return from lost, TZ04 will restore the switch state which could be SWITCH OFFLAST SWITCH STATESWITCH ON. The default setting is LAST SWITCH STATE. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 : Switch off |
1 | 1 : Last switch state |
2 | 2 : Switch on |
Whenever TZ04 switches to on, the auto off timer begin to count down. After the timer decrease to zero, it will switch off automatically. However if Auto off timer is set as 0, the auto off function will be disabled. The default setting is 0. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 : Disable auto off function |
1 - 32767 | 1-0x7FFF : 1s ~ 32767s |
Whenever a switch off command, BASIC_SETBINARY_SWITCH_SETSWITCH_ALL_OFF, is received, it could be interpreted as 4 kinds of commands. 1. Switch OffIt switches to OFF state. The default setting is Switch Off. 2. IgnoreThe switch off command will be ignored. 3. Switch ToggleIt switches to the inverse of current state. 4. Switch OnIt switches to ON state. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 : Switch off |
1 | 1 : Ignore |
2 | 2 : Switch toggle |
3 | 3 : Switch on |
Hardware Platform | SD3502 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.04 |
Z-Wave Version | 6.51.02 |
Certification ID | ZC10-16015005 |
Z-Wave Product Id | 0x0118.0x0001.0x0012 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |