Quickstart

This is a Multilevel Sensor for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Put the Z-Wave controller into add mode (refer to controller documentation for more information).Press the button on the sensor to add to the Z-Wave network. The LED on the sensor will go solid white when the sensor has been successfully added.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Battery powered indoor Z-Wave temperature sensor.Sense temperature in any room in the home.

Reset to factory default NOTE: Only reset the sensor to factory default when the primary controller is missing or inoperable.Press and hold the button for 15 seconds.Release the button after 15 seconds and the LED will blink rapidly when the sensor has been reset to factory default.
Inclusion Put the Z-Wave controller into add mode (refer to controller documentation for more information).Press the button on the sensor to add to the Z-Wave network. The LED on the sensor will go solid white when the sensor has been successfully added.
Exclusion Put the Z-Wave controller into remove mode (refer to the controller documentation for more information).Press the button on the sensor to remove from the Z-Wave network.The LED on the sensor will blink white when the sensor has been successfully removed.
NIF XXXNIF
Wakeup The temperature sensor will send wake up notifications when the button is pressed and the temperature sensor is already included in a Z-Wave network.It also sends wake up notifications based at time intervals specified in the wake up set command.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline.
2 5 Sensor Multilevel Temperature Report.

Configuration Parameters

Parameter 1: Wake Up Period

Number of seconds the sensor will stay in the Wake up state following a button press. The sensor will go to sleep if it receives a wake up no more information frame.
Size: 2 Byte, Default Value: 600

Setting Description
10 - 32768 Seconds to stay awake following button press

Parameter 2: Low Battery Level

Low Battery Report threshold.
Size: 2 Byte, Default Value: 1755

Setting Description
1000 - 2500 Battery level

Parameter 3: Temperature Reporting Threshold

The minimum temperature difference required to send a new ambient temperature report.
Size: 2 Byte, Default Value: 10

Setting Description
0 - 100 Tenths of a degree Fahrenheit.A value of 10 would be 1.0F.

Parameter 4: Configuration Bitmask

Configuration bitmask for various device configuration settings. Bit 0 - reserved.Bit 1 - If set to 1, sensor will send unsolicited temperature reports.Bits 2 to 15 - reserved
Size: 2 Byte, Default Value: 2

Setting Description
0 If zero, sensor will not send unsolicted temperature reports
2 If Bit 1 is set, sensor will send unsolicited temperature reports when the temperature changes.

Parameter 5: Battery Reporting Interval

The number wakeup intervals between autonomous battery reports.
Size: 2 Byte, Default Value: 8

Setting Description
0 - 255 Number of wake up intervals between autonomous battery reports.The wake up interval is set in the Wake Up Command Class.

Parameter 6: Temperature Checking Interval

The number of seconds between temperature readings.
Size: 2 Byte, Default Value: 60

Setting Description
10 - 255 The number of seconds between temperature readings

Parameter 7: Temperature Reporting Interval

The number wakeup intervals between autonomous temperature reports. These interval reports should be sent regardless of the setting of the temperature reporting threshold.
Size: 2 Byte, Default Value: 0

Setting Description
0 - 255 The number of wake up intervals between autonomous temperature reports.If this value is zero, autonomous temperature reporting based on wake up interval is disabled.

Parameter 8: Temperature Calibration Offset

Adjust reported temperature by +/- 10 degrees Fahrenheit for calibration.
Size: 2 Byte, Default Value: 0

Setting Description
-100 - 100 Tenths of a degree Fahrenheit.A value of 10 would be 1.0F.

Parameter 9: Mandatory Temperature Reporting Interval

Temperature will be reported regardless of differential from threshold.
Size: 2 Byte, Default Value: 7200

Setting Description
60 - 64800 The number of seconds between temperature reports.

Technical Data

Hardware Platform ZM5202
Device Type Multilevel Sensor
Network Operation Reporting Sleeping Slave
Firmware Version 01
Z-Wave Version 6.51.06
Certification ID ZC10-16010010
Z-Wave Product Id 0x0190.0x0003.0x0001
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoMultilevel Sensor