Quickstart

This is a On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1.Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. 2. Pressing On/Off button three times within 2 seconds will enter inclusion mode.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

This plug-in ON/OFF switch PAN15 is a security enabled wireless switch, based on Z-WavePlustechnology.Z-WavePlusTM enableddevicesdisplayingtheZ-Wave PlusTM logo can also be used with it regardless of the manufacturer, and can also be used in other manufacturers Z-WaveTM enabled networks. Remote On/Off control of the connected load is possible with other manufacturers wireless Controller. Each switch is designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstacles and radio dead spots. Because PAN15 supports Security Command Class, it can learn with Secured controller. Its functionality and supported command classes is identical when included as a secure and non-secure device.This plug-in ON/OFF switch is able to detect instance wattage (1560W/UL/TW/JP) and overload current (14.5A) of connected lights or appliances. When detecting overload state, the Switch will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, unplug and re-connect the switch will reset its overload condition to normal status.Adding to Z-WaveTM NetworkIn the front casing, there is an On/Off button with LED indicator which is used to toggle switch onand off or carryoutinclusion,exclusion, reset orassociation. When first power is applied, its LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies that it has not been assigned a node ID and start auto inclusion.Auto InclusionThe function of auto inclusion will be executed as long as the switch does not have Node ID and just plug the switch into a wall outlet.Note: Auto inclusion timeout is 2 minute during which the node information of explorer frame will be emitted once several seconds. Unlike inclusion function as shown in the table below, the execution of auto inclusion is free from pressing the On/Off button on the Switch.The table below lists an operation summary of basic Z-Wave functions. Please refer to the instructions for your Z-WaveTM Certificated Primary Controller to access the Setup function, and to include/exclude/associate devices

Reset to factory default Use this procedure only in the event that the primary controller is lost or otherwise inoperable. 1. Pressing On/Off button three times within 2 seconds will enter inclusion mode. Use this procedure only in the event that the primary controller is lost or otherwise inoperable.2.Within 1 second, press On/Off button again for 5 seconds. 3. IDs are reset.
Inclusion 1.Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. 2. Pressing On/Off button three times within 2 seconds will enter inclusion mode.
Exclusion 1.Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. 2. Pressing On/Off button three times within 2 seconds will enter exclusion mode. 3.Node ID has been excluded.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus LifelineThe Switch can be set to send reports to associated Z-Wave devices. It supports one association group with one node support for Grouping 1. For group 1, the Switch will report its latest status to Z-Wave Controller.Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT, ALARM_REPORT.

Configuration Parameters

Parameter 1: Watt Meter Report Period

If the setting is configured for 1hour (set value=720), the PAN15 will report its instant power consumption every 1 hour to Group1 node. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr).
Size: 2 Byte, Default Value: 720

Setting Description
1 - 32767 720*5s=3600s=1 hour

Parameter 11: Switch status report mode

Whenever the status of switches changes, it will send a Binary Switch report to the group1 node. The default setting is 1 (Enable).
Size: 1 Byte, Default Value: 1

Setting Description
0 0 : Disable
1 1 : Enable

Parameter 2: KWH Meter Report Period

If the setting is configured for 1hour (set value =6), the PAN15 will report its Accumulated Power Consumption (KW/h) every 1 hour to Group1 node. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days).
Size: 2 Byte, Default Value: 6

Setting Description
1 - 32767 6*10min=1 hour

Parameter 3: Threshold of current for Load Caution

This is a warning when the current of load over the preset threshold value, if the setting value is 1300, when the load current of Relay1 over this value, PAN15 will send current meter report to warn the Group1 node, the Range of the setting value is from 10 to 1300,and the default value is 1300.
Size: 2 Byte, Default Value: 1300

Setting Description
10 - 1300 1300*0.01A = 13A

Parameter 4: Threshold of KWh for Load Caution

This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 over this value, PAN15 will send KWH meter report to warn the Group1 node, minimum value is 1KWh and default value is 10000 kWh.
Size: 2 Byte, Default Value: 10000

Setting Description
1 - 10000 10000*1KWH=10000KWH

Parameter 5: Restore switch state mode

Whenever the AC power return from lost, PAN15 will restore the switch state which could be SWITCH OFFLAST SWITCH STATESWITCH ON. The default setting is LAST SWITCH STATE.
Size: 1 Byte, Default Value: 1

Setting Description
0 0 : Switch off
1 1 : Last switch state
2 2 : Switch on

Parameter 6: Mode of switch off function

When the mode of switch On/Off is set to 0, any command of switch off will be disabled and the On/Off function of include button will be disabled. The default setting is enable mode.
Size: 1 Byte, Default Value: 1

Setting Description
0 0 : Disable
1 1 : Enable

Parameter 7: LED indication mode

1. Show Switch StateWhen switch is on, LED is on. When switch is off, LED is off. The default setting is Show Switch State. 2. Show Night modeWhen switch is on, LED is off. When switch is off, LED is on.
Size: 1 Byte, Default Value: 1

Setting Description
1 1 : Show switch state
2 2 : Show night mode

Parameter 8: Auto off timer

Whenever PAN15 switches to on, the auto off timer begin to count down. After the timer decrease to zero, it will switch to off automatically. However if Auto off timer is set as 0, the auto off function will be disabled. The default setting is 0.
Size: 2 Byte, Default Value: 0

Setting Description
0 0 : Disable auto off function
1 - 32767 1-0x7FFF : 1s ~ 32767s

Parameter 9: RF off command mode

Whenever a switch off command, BASIC_SETBINARY_SWITCH_SETSWITCH_ALL_OFF, is received, it could be interpreted as 4 variety of commands. 1. Switch OffIt switches to OFF state. The default setting is Switch Off. 2. IgnoreThe switch off command will be ignored. 3. Switch ToggleIt switches to the inverse of current state. 4. Switch OnIt switches to ON state.
Size: 1 Byte, Default Value: 0

Setting Description
0 0 : Switch off
1 1 : Ignore
2 2 : Switch toggle
3 3 : Switch on

Technical Data

Hardware Platform SD3502
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version 01
Z-Wave Version 6.51.06
Certification ID ZC10-16010002
Z-Wave Product Id 0x013C.0x0001.0x0028
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoOn/Off Power Switch