Quickstart

This is a On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
When a PS132ZW that is not associated to a Z-Wave network is inserted into the mains outlet, it will flash once red followed by 2 green flashes followed by steady red flashing. The PSC132ZW can now be added to (=inclusion) or removed from (=exclusion) a Z-Wave network:1) start inclusion/exclusion on the primary controller2) hold the touch button until the ledshows green light3) release the touch buttonThe PSC234 will confirm successful addition to the network by 5 green flashes.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The wireless flush-mount switching actuator PSC132ZW allows you to remotely control electrical appliances. It features a metering function to measure the power consumption and the accumulated energy usage of connected equipment. The built-in metering unit is of high quality: it calculates the true-power and also works for small loads from 1W upwards. This feature is important to have a correct measurement value also for electronic loads like led lamps.The PSC132ZW has a built-in safety features that will switch-off the output in case of too high temperature or overload.Additionally the PSC132 has a feature to switch the load on at zero voltage and switch the load off at zero current. This leads to a very high number of possible switching cycles also for difficult loads like led-lamps or motors, e.g. pumps.

Reset to factory default Please use this procedure only if the primary controller is missing or inoperable:The device can be put into factory default state manually by the following procedure:1) hold the touch-button until the led shows red light2) release the touch-button and hold the touch-button again until the led starts to flash greenThe PSC132ZW confirms the successful completion of the factory reset procedure by steady red flashing.
Inclusion When a PS132ZW that is not associated to a Z-Wave network is inserted into the mains outlet, it will flash once red followed by 2 green flashes followed by steady red flashing. The PSC132ZW can now be added to (=inclusion) or removed from (=exclusion) a Z-Wave network:1) start inclusion/exclusion on the primary controller2) hold the touch button until the ledshows green light3) release the touch buttonThe PSC234 will confirm successful addition to the network by 5 green flashes.
Exclusion When a PS132ZW that is not associated to a Z-Wave network is inserted into the mains outlet, it will flash once red followed by 2 green flashes followed by steady red flashing. The PSC132ZW can now be added to (=inclusion) or removed from (=exclusion) a Z-Wave network:1) start inclusion/exclusion on the primary controller2) hold the touch button until the ledshows green light3) release the touch buttonThe PSC234 will confirm successful removal/exclusion by steady red flashing. At the time of exclusion the device is factory reset.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Group1 Z-Wave Plus LifelineEvents/Notifications:(1)Sends COMMAND_CLASS_BASIC, BASIC_REPORT after every change of the output state (on/off). (2)Sends COMMAND_CLASS_METER_V2, METER_REPORT_V2 after every change of the measured energy or power value or after a timeout if the values stay unchanged. during If the energy or power value didnt change for a certain time.Min. time between 2 reports if the energy or power value changes: 1sTimeout for sending a report if the value stays unchanged: 15min.Min. change in value to trigger a report:4% power (mind. 2W) oder 1Wh energy
2 5 Events/Notifications:Sends COMMAND_CLASS_BASIC, BASIC_REPORT every time the mechanical switch at the input S1 is operated.

Configuration Parameters

Parameter 31: Local Control Off

If LocalControlOn is set (factory default state) the PSC132ZWs output can be switched manually by a mechanical rocker-switch or a pushbutton that is connected to the S1 input of the device. If LocalControlOff is set, the PSC132ZWs output can only be switched through Z-wave telegrams. In both modes the operational state of the mechanical switch is reported to association group 2. LocalControlOff is ment for using the switch-input functionality and the relay functionality separately.
Size: 1 Byte, Default Value: 0

Setting Description
0 Local Control On
1 Local Control Off

Technical Data

Hardware Platform ZM5101
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 255
Z-Wave Version 6.51.06
Certification ID ZC10-15120005
Z-Wave Product Id 0x0245.0x0003.0x0002
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)On/Off Power Switch