This is a
When the HSM200 has not yet been joined to a Z-Wave network, the LED blinks aqua.To Include: Put the controller into learn mode, (in the HomeSeer Z-Wave Plug-in, choose controller functions and add/include device.) then press and release the push button on the side of the HSM200. The LED will blink blue while the HSM200 is trying to join the Z-Wave network.Once joined to the network, the HSM200 enters a motion sensor test mode and the LED will blink white each time motion is detected. This mode lasts for about 5 minutes and then the LED will go out.If the HSM200 is unable to join the network, it will return to blinking aqua.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
The HSM200 senses motion, temperature and light level, can function as a night light, and can also be programmed to display up to 7 different glowing colors when things happen in the home! Since the HSM200 is line powered, there are no batteries to change and the unit automatically operates as a Z-Wave network repeater.Installation is fast and easy. Just plug into any available 120v outlet and tap the button on the side to join it to your Z-Wave network. HSM200 is compatible with any HomeSeer HS3-based system, including the full line of HomeTrollers, and Z-Wave systems from 3rd parties.HomeSeer users can create events to display different colors when motion is sensed, doors are opened, water leaks are detected or just about anything else happens in the home. Color optionsinclude red, green, blue, yellow, magenta, cyan and white. The unit can also be programmed to work as a night light after hours.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Excluding from a Z-Wave network will return the device to factory defaults. See the Product Exclusion Description for details.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
2 | 4 | This group is used to directly turn lights on or off when motion is detected. Up to four (4) Z-Wave devices can be associated in this group. The HSM200 will send a BASIC ON command to all devices that are associated in this group. Note that the Z-Wave devices in this group must be within direct range (about 30) of the HSM200. Control of nodes that are further away or blocked by metal or concrete walls should rely on the Z-Wave system controller and the home-control application for reliable operation. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
OnTime sets the number of minutes that the lights stay on when motion has not been detected.A value of 0 is a special mode where the lights are constantly sent a command to turn them on whenever motion is detected. The HSM200 will NOT turn the lights off in this mode. Recommended values:5 min for hallways20 min for an office environment60 min for a library, office or other room where someone may be sitting still for a long time Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | Send only ON every time motion is detected |
1 - 127 | Minutes of No Motion before OFF sent |
OnLevel is the value sent by the Z-Wave BASIC_SET command to all Group 2 nodes when motion is detected. A value of 0 will turn the lights off (not recommended).A value between 1 and 99 will set the dim level to between 1% and 99% (99% is full on).A value of -1 will turn the light on which depends on the device but most will set the dim level to the last dim setting. Size: 1 Byte, Default Value: -1
Setting | Description |
---|---|
1 - 99 | Dim level |
-1 | ON |
A Luminance report is sent to the system controller every LiteMin minutes if the value has changed by more than 5% since the last reading.A value of zero turns this mode off. Luminance values can still be obtained at any time by the home-control application in this mode. Size: 1 Byte, Default Value: 60
Setting | Description |
---|---|
1 - 127 | Minutes between light level reports |
0 | Disable |
A Temperature report is sent to the system controller every TempMin minutes if the value has changed by more than 0.5F since the last reading.A value of zero turns this mode off. Temperature values can still be obtained at any time by the home-control application in this mode. Size: 1 Byte, Default Value: 60
Setting | Description |
---|---|
0 | Disable |
1 - 127 | Minutes between temperature reports |
TempAdj is a twos-complement number that is used to adjust the temperature reading to make it more accurate. The value is in tenths of degree Fahrenheit. The temperature reading can be adjusted up to +12.7F to -12.8F. A value of 1 will adjust the temperature reading by +0.1F. A value of -1 will adjust the temperature by -0.1F. A value of 123 will adjust the temperature by +12.3F. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-127 - 128 | Temperature adjust by 1/10th this value |
Hardware Platform | ZM5202 |
Device Type | Notification Sensor |
Network Operation | Always On Slave |
Z-Wave Version | 6.51.03 |
Certification ID | ZC10-15020009 |
Z-Wave Product Id | 0x001E.0x0004.0x0001 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |