This is a
The multiple sound siren PSE02 is a wireless siren, based on Z-Waveâ„¢ technology. It is the Z-Waveâ„¢ plus product, it support the security, OTA... Those newest features of the Z-Waveâ„¢ technology. Z-Waveâ„¢ is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances.
Reset to factory default | Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable. 1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4 pressed, and the LED will light ON. 2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once. 3. IDs are excluded and all settings will reset to factory default. |
Inclusion | 1. Have Z-Waveâ„¢ Controller entered inclusion mode. 2. Pressing tamper key three times within 1.5 seconds to enter the inclusion mode. 3. After add successful, the LED will light ON 1 second |
Exclusion | 1. Have Z-Waveâ„¢ Controller entered exclusion mode. 2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode. Node ID has been excluded. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 8 | The group 1 is for receiving the report message, like tamper event. This is the device's Lifeline group. The group supports 8 nodes maximum. |
As long as this device is not included into a Z-Wave network of a different controller it is able to manage its own Z-Wave network as primary controller. As a primary controller the device can include and exclude other devices in its own network, manage associations, and reorganize the network in case of problems. The following controller functions are supported:
Communication between two Z-Wave devices only works if both belong to the same wireless network. Joining a network is called inclusion and is initiated by a controller. The controller needs to be turned into the inclusion mode. Once in this inclusion mode the other device needs to confirm the inclusion - typically by pressing a button.
If current primary controller in your network is in special SIS mode this and any other secondary controller can also include and exclude devices.
To become primary a contoller have to be resetted and then include a device.
1. Have Z-Wave Controller entered inclusion mode.2. Pressing tamper key three times within 1.5 secondsto enter the inclusion mode.3. After add successful, the LED will light ON 1 second
The primary controller can exclude devices from the Z-Wave network. During exclusion the relationship between the device and the network of this controller is terminated. No communication between the device and other devices still in the network can happen after a successful exclusion. The controller needs to be turned into the exclusion mode. Once in this exclusion mode the other device needs to confirm the exclusion - typically by pressing a button.
Attention: Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from it's previous network.
1. Have Z-Wave Controller entered exclusion mode.2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode.Node ID has been excluded.
Alarm function enable/disable. Caution: After the power up, this configuration always be 0. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Enable Alarm. |
1 | Disable Alarm |
Play alarm sound duration, 1 tick is 30 seconds. Default is 3 minutes, maximum is 63.5 minutes 0: means never auto stop. Size: 1 Byte, Default Value: 6
Setting | Description |
---|---|
0 | means never auto stop. |
1 - 127 | Play alarm sound duration, 1 tick is 30 seconds. |
Bit 4: Notification Type Setting Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Using Notification Report. |
16 | Using Sensor Binary Report. |
Hardware Platform | SD3502 |
Device Type | Siren |
Network Operation | Always On Slave |
Firmware Version | 01 |
Z-Wave Version | 6.51.02 |
Certification ID | ZC10-14110002 |
Z-Wave Product Id | 0x013C.0x0004.0x000A |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |