Quickstart

This is a On/Off Power Switch for CEPT (Europe). To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1.Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. 2.Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode.

Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.


Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.

If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

This in-wall dual relay switch module is a transceiver which is a Z-Wave Plus enabled device and is fully compatible with any Z-Wave enabled network.Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration. There are many kind of application by using the module to switch AC power On and Off, one main application is the light control. The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of light like incandescent, fluorescent and LED light.This in-wall switch module is able to detect Instant power wattage and overload current (7.5A) of connected light or appliances. When detecting overload state, the Module will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, disconnect and re-connect the Module will reset its overload condition to normal status.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.

This procedure should only be used in the event the primary controller is lost or otherwise inoperable.1.Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode. 2.Within 1 second, press INCLUDE_BUTTON again for 5 seconds. 3.IDs are excluded.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

1.Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. 2.Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode.

Exclusion

1.Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. 2.Pressing INCLUDE_BUTTON three times within 2 seconds will enter exclusion mode.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number Maximum Nodes Description
1 1 For group 1, the Switch will report (1) ON/OFF status of Relay1 and Relay2 (2) InstantPowerConsumption(Watt)ofRelay1andRelay2(3)Accumulated Power Consumption (KWh) of Relay1 and Relay2 to Group1 node.
2 1 Forgroup2,theSwitchwillreport(1)ON/OFFstatusofRelay1(2)Instant PowerConsumption(Watt)ofRelay1(3)AccumulatedPowerConsumption (KWh) of Relay1 to Group2 node.
3 1 Forgroup3,theSwitchwillreport(1)ON/OFFstatusofRelay2(2)Instant PowerConsumption(Watt)ofRelay2(3)AccumulatedPowerConsumption (KWh) of Relay2 to Group3 node.

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.

Parameter 1: Watt Meter Report Period

If the setting is configured for 1hour (set value =720), the PAN04 will report its instant power consumption every 1 hour to the node of correspond Group. The maximumintervaltoreportitsinstantpowerconsumptionis45hours (5s*32767/3600=45hr).
Size: 2 Byte, Default Value: 720

Setting Description
1 - 32767 Each value is a 5 second period.

Parameter 10: ExistenceofEndpoint3

Multi-Channel Command is a good way to control relay1 and relay2 of PAN04 individually. The endpoint3 of PAN04 is related to both relay1 and relay2. In some condition it becomes redundant in Multi-Channel Command Class. When the Existence of Endpoint3 is set as 2, the endpoint3 will be disabled. The default value is 1. Endpoint1 and Endpoint2 are fixed, only Endpoint3 is dynamic.
Size: 1 Byte, Default Value: 1

Setting Description
2 No Endpoint 3
1 Endpoint 3 exists

Parameter 2: KWH Meter Report Period

If the setting is configured for 1hour (set value =6), the PAN04 will report its Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond Group. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days).
Size: 2 Byte, Default Value: 6

Setting Description
1 - 32767 Each value is one 10 minute period.

Parameter 3: Selected Relay

If Controller not using Multi_Channel command class to access the relay of PAN04,youmayconfiguretheselectvaluetoreacttheBasicCommand ClassBinary Switch Command Class or Meter Command Class V3.
Size: 1 Byte, Default Value: 3

Setting Description
2 Relay2 can be controlled and will report
3 Relay1 and Relay2 can be controlled and report.
1 Relay1 can be controlled and will report.

Parameter 4: Edge orPulsemode orEdge-Toggl e mode

Edge mode: this mode is suitable for the bi stable wall switch that has indicator pointon the switch, and the same position correspond to same state of relay1 and relay2. if the PAN04 relay change the state because of receiving Z-Wave RF command, it may need two times of change (switch on to off or switch off to on) to let relay back to the correspond state.Pulse mode: this mode is suitable for the toggle type wall switch to swap the state of Relay1 or Relay2. Edge-Toggle mode: this mode is suitable for the normal bi-stable switch, every time when change the state of the wall switch will also swap the state of Relay1 or Relay2.
Size: 1 Byte, Default Value: 1

Setting Description
2 Pulse mode
3 Edge-Toggle mode
1 Edge mode

Parameter 5: Threshold of current for Load Caution

This is a warning when the current of load over the preset threshold value, if the setting value is 750, when the load current of Relay1 or Relay2 over this value, PAN04 will send current meter report to the node of correspond Group, the Range of the setting value is from 10 to 750, and the default value is 750.
Size: 2 Byte, Default Value: 750

Setting Description
10 - 750 Each value is 0.01A, e.g. 750*0.01A = 7.5A

Parameter 6: Threshold of KWh for Load Caution

This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 or Relay2 over this value, PAN04 will send KWh Meter Report command to the node of correspond Group, minimum value is 1KWh and default value is 10000 kWh.
Size: 2 Byte, Default Value: 10000

Setting Description
1 - 10000 KWh Load Caution Meter Report threshold value

Parameter 7: Restore switch state mode

Whenever the AC power return from lost, PAN04 will restore the switch state which could be SWITCH OFFLAST SWITCH STATESWITCH ON. The default setting is LAST SWITCH STATE.
Size: 1 Byte, Default Value: 1

Setting Description
1 Last switch state
2 Switch on
0 Switch off

Parameter 8: Auto off timer

Whenever PAN11 switches to on, the auto off timer begin to count down. After the timer decrease to zero, it will switch off automatically. However if Auto off timer is set as 0, the auto off function will be disabled. The default setting is 0.
Size: 2 Byte, Default Value: 0

Setting Description
1 - 32767 Each value is the number of seconds for the auto off timer.
0 Disable auto off function

Parameter 9: RF off command mode

Whenever a switch off command, BASIC_SET BINARY_SWITCH_SET SWITCH_ALL_OFF, is received, it could be interpreted as 4 kinds of commands. 1. Switch OffIt switches to OFF state. The default setting is Switch Off. 2. IgnoreThe switch off command will be ignored. 3. Switch ToggleIt switches to the inverse of current state. 4. Switch OnIt switches to ON state.
Size: 1 Byte, Default Value: 0

Setting Description
1 Ignore
2 Switch toggle
3 Switch on
0 Switch off

Technical Data

Hardware Platform SD3502
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version 01
Z-Wave Version 6.51.02
Certification ID ZC10-14110001
Z-Wave Product Id 0x013C.0x0001.0x0012
Frequency XXfrequency
Maximum transmission power XXantenna

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall controllers.
  • Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.
  • Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.
  • Inclusion — is the process of adding new Z-Wave devices into a network.
  • Exclusion — is the process of removing Z-Wave devices from the network.
  • Association — is a control relationship between a controlling device and a controlled device.
  • Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.
  • Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.