Quickstart
This is a
Notification Sensor for XXXQFrequencyName.
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
Put the Z-Wave Interface Controller into inclusion mode, and following its instruction to add the ZS6101-5 to your controller. To get in the inclusion mode, the distance between detector and controller is suggested to be in one meter. Press the program switch of ZS6101-5 for 1 second at least to be included. After setting, the LED Setting Lighting should go off, if not, please try again. (Please refer to the user manual to understand the program switch location)
Important safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from
Z-Wave Alliance Product
data and may be incomplete. Please refer to the
Manufacturers Manual for more information.
Product Description
The ZS6101US-5 is a Z-WAVE enabled smoke detector which is designed to sense smoke that comes into the detector's chamber and send Z-WAVE signal and warning sound (with audibility as 85dB at 3m) if it detects a certain density of smoke. The detector is battery operated and includes the ability to detects the battery level and will report an alert signal if the battery is under certain low level. The sensitivity of its sensor is meet both UL217 and EN14604 standard. The ZS6101US-5 also supports its firmware could updated over Z-WAVE network.
Reset to factory default |
XXXResetDescription |
Inclusion |
Put the Z-Wave Interface Controller into inclusion mode, and following its instruction to add the ZS6101-5 to your controller. To get in the inclusion mode, the distance between detector and controller is suggested to be in one meter. Press the program switch of ZS6101-5 for 1 second at least to be included. After setting, the LED Setting Lighting should go off, if not, please try again. (Please refer to the user manual to understand the program switch location) |
Exclusion |
Put the Z-Wave Interface Controller into exclusion mode, and following its instruction to delete the ZS6101-5 from your controller. Press the program switch of ZS6101-5 for 1 second at least to be excluded.The red LED setting light will flash continuously in Exclusion condition. (Please refer to the user manual to understand the program switch location) |
NIF |
XXXNIF |
Wakeup |
Press program switch once, the detector will send a Node Information Frame signal first and will also send a Wake Up Notification after 3 seconds. (Please refer to the user manual to understand the program switch location) |
Protection |
XXXProtection |
FirmwareUpdate |
XXXFirmwareUpdate |
SetAssociation |
XXXSetAssociation |
Association Groups:
Group Number |
Maximum Nodes |
Description |
1 |
5 |
Z-Wave Plus Lifeline |
Technical Data
Hardware Platform |
ZM5202 |
Device Type |
Notification Sensor |
Network Operation |
Reporting Sleeping Slave |
Firmware Version |
01 |
Z-Wave Version |
6.51.02 |
Certification ID |
ZC10-14100004 |
Z-Wave Product Id |
0x0109.0x2004.0x04A4 |
Frequency |
XXfrequency |
Maximum transmission power |
XXantenna |